The Filling Balance of LDPE/ABS/PA6,6 Resin in Variable-Runner-System  

Park, H.P. (한국생산기술연구원 정밀금형팀)
Cha, B.S. (한국생산기술연구원 정밀금형팀)
Kang, J.K. (아주대학교 기계공학과)
Rhee, B.O. (아주대학교 기계공학과)
Publication Information
Transactions of Materials Processing / v.15, no.9, 2006 , pp. 641-647 More about this Journal
Abstract
During the injection molding process an excessive packing can occur in the smaller volume cavity because of volumetric difference of the family-mold. It causes warpage by increased residual stress in the product and flesh by over packing. In this study, we used a variable-runner system for the filling balance of the cavities by changing the cross-sectional area of a runner, and confirmed the filling imbalance by temperature and pressure sensors. We carried out experiments to examine the influence of types of resins such as LDPE/ABS/PA6,6 on the filling balancing of the system, in order to help mold designers, who can easily adopt the variable-runner system to their design. We also examined filling imbalance in the system with CAE analysis.
Keywords
Injection Molding; Filling Imbalance; Variable-Runner System;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 J. P. Beaumont, J. H. Young, 1997, Mold filling imbalances in geometrically balanced runner systems, Journal of Injection Molding Technology, Vol. 1, No.3, pp. 133-135
2 M. R. Karmal, W. I. Patterson, N. Conley, D. Abu Fara, G. Lohfink, 1987, Dynamics and control of pressure in the injection molding of thermoplastics, Polymer Engineering and Science, Vol. 27, pp. 1403-1410   DOI   ScienceOn
3 S. Orzechowski, A. Parism, C. Dobbin, 1998, A Process Monitoring and Control System for Injection Molding using Nozzle-based Pressure and Temperature Sensors, ANTEC98, Vol. 1, pp. 733-742
4 Y. D. Jeong, 2006, Development of new runner system for filling balance in multi cavity injection mold, Transactions of Materials Processing, Vol. 15, No. 1, p. 42   과학기술학회마을   DOI   ScienceOn
5 M. Wolbert, B. Zore, 2005, Shear imbalance effects on gas distribution in gas-assist injection molding, ANTEC2006, Vol. 3, pp. 3774-3777
6 J. P. Coulter, 2003, Cavity specific control of melt flow during injection molding processes, Conference proceedings of ASME International Mechanical Engineering Congress & Exposition, Washington, D.C., Vol. 3
7 P. Kennedy, 1995, Flow analysis of injection molds, Hanser & Gardner Publications Inc., New York, Cincinnati
8 C. Collins, 1999, Monitoring cavity pressure perfects injection molding, Assembly Automation, Vol. 19, No.3, pp. 197-202   DOI
9 D. Kazmer, P. Barkan, 1997, The process capability of multi-cavity pressure control for the injection molding process, Polymer Engineering and Science, Vol. 37, No. 11, pp. 1880-1891   DOI   ScienceOn
10 W. I. Patterson, 1990, Mold temperature measurement and control, ANTEC90, pp. 227-232