Browse > Article
http://dx.doi.org/10.21289/KSIC.2022.25.2.309

A Study on the Bonding Strength of Titanium Artificial Teeth for Baking Dental Ceramics using Micro-arc Oxidation Surface Treatment Technology  

Song, Jong-Beop (MD Co.Ltd, research center, Dept. of Bio-Industrial Machinery Engineering, Pusan National University)
Park, Jong-Min (Dept. of Bio-Industrial Machinery Engineering, Pusan National University)
Kim, Jong-Soon (Dept. of Bio-Industrial Machinery Engineering, Pusan National University)
Jung, Hyo-Kyung (Dept. of Dental Laboratory, Daegu Health College)
Choi, Won-Sik (Dept. of Bio-Industrial Machinery Engineering, Pusan National University)
Publication Information
Journal of the Korean Society of Industry Convergence / v.25, no.2_2, 2022 , pp. 309-314 More about this Journal
Abstract
The bonding strength [ISO22674] test was conducted by firing a dedicated ceramic powder on the surface of the dental titanium material treated with micro-arc oxidation. In the test group, an average result value of 34.34 MPa was obtained, and in the control group, a result value of 21.53 MPa was obtained. The bonding strength of the test group was higher than that of the control group by 12.81 MPa, resulting in a 37% improvement in durability of the dental artificial tooth ceramic restoration.
Keywords
Plasma Electrolytic Oxidation; PEO; Dental Ceramics; Dental Titanium; Artificial Teeth; Bonding Strength Test;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Kim, J.-J., Jeong, Y.-H., & Choe, H.-C. (2017, April 1). Phenomena of Nano- and Micro-Pore Formation on Ti-(10~50). Ti Alloys by Plasma Electrolytic Oxidation for Dental Implants. Journal of Nanoscience and Nanotechnology. American Scientific Publishers. https://doi.org/10.1166/jnn.2017.13334   DOI
2 Li D, Ferguson SJ, Beutler T, Cochran DL, Sittig C, Hirt HP, Buser D. Biomec hanical comparison of the sandblasted and acid-etched and the machined and ac id-etched titanium surf ace f or dental implants. J Biomed Mater Res 2002;60:325-332.   DOI
3 C. J. Chung and H. Y. Long, "Systematic strontium substitution in hydroxyapatite coatings on titanium via micro-arc treatment and their osteoblast/osteoclast responses," Acta Biomater., 7, 4081-4087 (2011).   DOI
4 K. C. Kung, T. M. Lee and T. S. Lui, "Bioactivity and corrosion properties of novel coatings containing strontium by micro-arcoxidation," J. Alloy. Compd., 508, 384-390 (2010).   DOI
5 A. L. Yerokhin, X. Nie, A. Leyland, A. Matthews, and S. J. Dowey, Surface and Coatings Technology, 122, 73 (1999). [DOI: http://dx.doi.org/10.1016/S0257-8972(99)00441-7]   DOI
6 K. C. Kung, T. M. Lee, J. L. Chen and T. S. Lui, "Characteristics and biological responses of novel coatings containing strontium by micro-arc oxidation," Surf. Coat. Tech., 205, 1714-1722 (2010).   DOI
7 Carlsson L, Rostlund T, Albrektsson B, Albrektsson T, Removal torques for polished and rough titanium implants. Int J Oral Maxillofac Implants 1988;3: 21-24.
8 Ellingsen JE. Improved retention and bone-to-implant contact with fluoride-modified Titanium implants. Int J Oral Maxillofac Implants 2004; 19:659-666.
9 Kamal M, Joanna W, Blanca SL, Ann W, Kjell H, Kristina A, Determining optimal surface roughness of TiO2 blasted titanium implant material for attachment, proliferation and differentiation of cells derived from human mandibular alveolar bone. Clin Oral Imp Res 2001:12:515-525.   DOI
10 Morabito N. Three-year effectiveness of intravenous pamidronate versus pamidro nate plus slow-release sodium fluoride for postmenopausal osteoporosis. Osteo porosis Int 2003; 14:500-506.   DOI
11 S. Szmukler-Moncler, T. Testori, JP. B ernard, "Etched implants: a comparative surface analysis of four implant systems ", J. Biomed. Mater. Res., 15;69B, p. 46 (2004).   DOI
12 D. Buser, N. Broggini, M. Wieland, RK. Schenk, AJ. Denzer, DL. Cochran, B. Hoffmann, A. Lussi, SG. Steinemann, "En hanced bone apposition to a chemically modified SLA titanium surface", J. Dent. Res.,83 (7) p. 529 (2004).   DOI
13 A. L. Yerokhin, X. Nie, A. Leyland, A. Matthews, and S. J. Dowey, Surface and Coatings Technology, 122, 73 (1999). [DOI: http://dx.doi.org/10.1016/S0257-8972(99)00441-7]   DOI