A Tuned Liquid Mass Damper(TLMD) for Controlling Bi-directional Responses of a Building Structure  

Heo, Jae-Sung (단국대학교 건축대학 건축공학과)
Park, Eun-Churn (단국대학교 건축대학 건축공학과)
Lee, Sang-Hyun (단국대학교 건축대학 건축공학과)
Lee, Sung-Kyung (단국대학교 건축대학 건축공학과)
Kim, Hong-Jin (경북대학교 건설공학부 건축공학과)
Cho, Bong-Ho (포항산업과학연구원)
Jo, Ji-Seong (포스코 기술연구소)
Kim, Dong-Young (동일고무벨트)
Min, Kyung-Won (단국대학교 건축공학과)
Publication Information
Transactions of the Korean Society for Noise and Vibration Engineering / v.18, no.3, 2008 , pp. 345-355 More about this Journal
Abstract
This paper presents a design of a tuned liquid mass damper(TLMD) for controlling bi-directional response of high-rise building structure subjected to windload. The proposed damper behaves as a tuned mass damper(TMD) of which mass is regarded as the mass of a tuned liquid column damper(TLCD) and the case wall of the TLCD itself in one direction and the TLCD in the other direction. Because the proposed device has coupled design parameter along two orthogonal directions, it is very important to select designing components by optimal fine tuning. In the designing TLMD, for easy maintenance, the rubber-bearing with small springs was applied in TMD direction. In this study, the Songdo New City Tower 1A in Korea, which has been designed and constructed two TLCDs in order to control bi-directional response, was chosen as the model building structure. The results of rotation test proved the effectiveness of bi-directional behavior of TLMD.
Keywords
Two-way Tuned Liquid Mass Damper; Tuned Liquid Column Damper; Tuned Mass Damper; Shaking Table Test;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Lee, S.-K., Park, E. C., Min, K.-W., Lee, S.-H. and Park, J.-H., 2007, 'Experimental Implementation of a Building Structure with a Tuned Liquid Column Damper based on the Real-time Hybrid Testing Method', Journal of Mechanical Science and Technology, Vol. 21, pp. 885-890   과학기술학회마을   DOI   ScienceOn
2 Den Hartog, J. P., 1956, Mechanical Vibrations, 4th edn, McCraw-Hill, New York
3 Soong, T. T. and Dargush, G. F., 1997, Passive Energy Dissipation Systems in Structural Engineering, New York, John Wiley & Sons
4 Sakai, F., Takaeda, S. and Tamaki, T., 1989, 'Tuned Liquid Column Damper-new Type Device for Suppression of Building Vibrations', Proc. Int Conf. on Hight Rise Building, Nanjing, China, pp. 25-27
5 Chang, C. C. and Hsu, C. T., 1998, 'Control Performance of Liquid Column Vibration Absorbers', Engineering Structures, Vol. 20, No. 9, pp. 580-586   DOI   ScienceOn
6 Wright, G., 2002, 'Steadying Influence -Damper Systems Save Millions in Cost, While Reducing Lateral Movement in Tall Buildings', Building Design & Constuction
7 Pradipta Banerji, Mohan Murudi, Arvind H. Shah, Neil Popplewell, 2000, 'Tuned Liquid Dampers for Controlling Earthquake Response of Structures', Earthquake Engineering & Structural Dynamics, Vol. 29 No. 5, pp. 587-602   DOI   ScienceOn
8 Haskett, T., Breukelman, B., Robinson, J. and Kottelenberg, J., 'Tuned Mass Dampers Under Excessive Structural Excitation', Response of Structures to Extreme Loading(Conference), pp. 37-43
9 Ahsan, K., Rtacy, K. and Yukio, T., 1999, 'Mitigation of Motions of Tall Buildings with Specific Examples of Recent Applications', Wind and Structures, Vol. 2 No. 3, pp. 201-251   DOI   ScienceOn
10 Jangid, R. S., 1995, 'Dynamic Characteristics of Structures with Multiple Tuned Mass Dampers', Structural Engineering and Mechanics, Vol. 3, No. 5, pp. 497-509   DOI   ScienceOn