Usability Study on Public Access Defibrillator  

Oh, Young-Jin (Dept. of Management Information System in Sangji University)
Publication Information
Journal of Korean Society of Industrial and Systems Engineering / v.32, no.1, 2009 , pp. 61-66 More about this Journal
Abstract
Usability study of the CU Medical "i-PAD" AED was conducted to validate the usability of the device, primarily focused on the trained user as well as the utility of the training material. Comparing these results of the trained participants to those obtained by Callejas et al. (2004), who studied video-trained users of two commercially available Philips AEDs (FR2 and HS1) using a male manikin only, the participants in this study were more successful (100% vs. 85.7%-FR2 vs. 88.9%-HS1) and faster to shock (58.5s-i-PAD vs. 91s-FR2 vs. 90s-HS1). While the focus of this study was on validating ease of use for trained bystanders, the results of the untrained condition showed that, from a usability perspective, these devices perform as well as any other AEDs already approved and available for purchase for untrained bystander use, as evidenced by the comparison to various published research results.
Keywords
PAD; Automatic External Defibrillator; Sudden Cardiac Arrest; User Interface;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Callejas, S., Barry, A., Demertsidis, E., Jorgenson, D., and Becker, L. B.; "Human factors impact successful lay person automated external defibrillator use during simulated cardiac arrest," Critical Care Medicine, 32(9), 2004   DOI   ScienceOn
2 Takumi Taniguchi et al.; "Attitudes towards Automated External Defibrilltor Use in Japan," Resuscitation(in press Resus-3653), 2008
3 김미선; “병원 전 단계에서 자동체외 제세동을 이용한 효과적인 응급처지방법에 관한 연구”, 광주보건대학 논문집, 25, 2000
4 Eames, P., Larsen, P. D., and Galletly, D. C.; "Comparison of ease of use of three automated external defibrillators by untrained lay people," Resuscitation, 58 : 25-30, 2003   DOI   ScienceOn
5 Fleischhackl, R., Losert, H., Haugk, M., Eisenburger, P., Sterz, F., Laggner, A. N., and Herkner, H.; "Differing operational outcomes with six commercially available automated external defibrillators," Resuscitation, 62 : 167-174, 2004   DOI   ScienceOn
6 Wirklund, M. E.; "Medical Device That Talk-Talking medical device can enhance the way users interact with such product. But can you ensure that your device is actually helpful?," http://www.devicelink.com/mddi/archive/03/11/003.html, 2003
7 Edworthy J., Hellier E., and Rivers J.; "The Use of Male or Female Voices in Warnings System : A Question of Acoustics," Noise and Health, 6(21), 2003   ScienceOn
8 이강현, 황성오 외; “자동 제세동기 교육결과의 분석”, 대한 응급의학회지, 8(4), 1998
9 FDA CDRH; Medical Device Use-Safety: Incorporating Human Factors Engineering into Risk Management, U.S. Dept. of Health and Human Service FDA, 2000
10 국회 보건복지위원회; “응급의료에 관한 법률 일부 개정법률안”, 국회 의안정보시스템, 2007
11 Andre, Anthony D. et al.; "Automated External Defibrillator Use by Untrained Bystanders: Can the Public-Use Model Work?," Prehospital Emergency Caare, 8(3), 2004   DOI   ScienceOn
12 Davis, Ellen et al., "Public Access Defibrillation: Psychological Consequences in Resonders," Resuscitation, 77 : 201-206, 2008   DOI   ScienceOn