1 |
P. Glikfeld, R. S. Hinz, and R. H. Guy, "Noninvasive Sampling of Biological Fluids by Iontophoresis", Pharm. Res., 1989, 6, 988-990.
DOI
|
2 |
G. Rao, P. Glikfeld, and R. H. Guy, "Reverse Iontophoresis: Development of a Noninvasive Approach for Glucose Monitoring", Pharm. Res., 1993, 10, 1751-1755.
DOI
|
3 |
M. S. Norn, "Tear Fluid pH in Normals, Contact Lens Wearers, and Pathological Case", Acta Ophthalmol., 1988, 66, 485-489.
|
4 |
D. H. Conrad, J. Goyette, and P. S. Thomas, "Proteomics as a Method for Early Detection of Cancer: A Review of Proteomics, Exhaled Breath Condensate, and Lung Cancer Screening", J. Gen. Intern. Med., 2008, 23, 78-84.
DOI
|
5 |
P. Glikfeld, R. S. Hinz, and R. H. Guy, "Noninvasive Sampling of Biological Fluids by Iontophoresis", Pharm Res., 1989, 6, 988-990.
DOI
|
6 |
Y. Luo, S. Nartker, H. Miller, D. Hochhalter, M. Wiederoder, S. Wiederoder, E. Setterington, L. T. Drzal, and E. C. Alocilja, "Surface Functionalization of Electrospun Nanofibers for Detecting E. coli O157:H7 and BVDV Cells in a Direct-charge Transfer Biosensor", Biosens. Bioelectron, 2010, 26, 1612-1617.
DOI
|
7 |
E. Spain, R. Kojima, R. B. Kaner, G. G. Wallace, J. O'Grady, K. Lacey, T. Barry, T. E. Keyes, and R. J. Forster, "High Sensitivity DNA Detection Using Gold Nanoparticle Functionalised Polyaniline Nanofibres", Biosens. Bioelectron., 2011, 26, 2613- 2618.
DOI
|
8 |
H. Liu and Y. Hsieh, "Ultrafine Fibrous Cellulose Membranes from Electrospinning of Cellulose Acetate", Inc. J. Polym. Sci., Part B: Polym. Phys., 2002, 40, 2119-2129.
DOI
|
9 |
J. Wang, "Glucose Biosensors: 40 Years of Advances and Challenges", Electroanalysis, 2001, 13, 983-988.
DOI
|
10 |
W. K. Son, J. H. Youk, T. S. Lee, and W. H. Park, "Electrospinning of Ultrafine Cellulose Acetate Fibers: Studies of a New Solvent System and Deacetylation of Ultrafine Cellulose Acetate Fibers", J. Polym. Sci. Part B: Polym. Phys., 2004, 42, 5-11.
DOI
|
11 |
Z. Ma, M. Kotaki, and S. Ramakrishna, "Electrospun Cellulose Nanofiber as Affinity Membrane", J. Membr. Sci., 2005, 265, 115-123.
DOI
|
12 |
S. Rauf, A. Ihsan, K. Akhtar, M. A. Ghauri, M. Rahman, M. A. Anwar, and A. M. Khalid, "Glucose Oxidase Immobilization on a Novel Cellulose Acetate-polymethylmethacrylate Membrane", J. Biotec., 2006, 121, 351-360.
DOI
|
13 |
K. O. Kim and B. S. Kim, "Immobilization of Glucose Oxidase on a PVA/PAA Nanofiber Matrix Reduces the Effect of the Hematocrit Levels on a Glucose Biosensor", J. Fiber Sci. Technol., 2017, 73, 27-33.
DOI
|
14 |
M. Tierney, J. Tamada, R. Potts, L. Jovanovic, and S. Garg, "Clinical Evaluation of the Glucowatch Biographer: a Continual, Non-invasive Glucose Monitor for Patients with Diabetes", Biosens. Bioelectron., 2001, 16, 621-629.
DOI
|