Browse > Article
http://dx.doi.org/10.5933/JKAPD.2019.46.2.226

Effect of Nano-filled Protective Coating on Microhardness and Wear Resistance of Glass-ionomer Cements  

Ryu, Wonjeong (Department of Pediatric Dentistry, Oral Science Research Center, College of Dentistry, Gangneung-Wonju National University)
Park, Howon (Department of Pediatric Dentistry, Oral Science Research Center, College of Dentistry, Gangneung-Wonju National University)
Lee, Juhyun (Department of Pediatric Dentistry, Oral Science Research Center, College of Dentistry, Gangneung-Wonju National University)
Seo, Hyunwoo (Department of Pediatric Dentistry, Oral Science Research Center, College of Dentistry, Gangneung-Wonju National University)
Publication Information
Journal of the korean academy of Pediatric Dentistry / v.46, no.2, 2019 , pp. 226-232 More about this Journal
Abstract
The purpose of this study was to investigate the effect of adding a protective coating on the microhardness and wear resistance of glass ionomer cements (GICs). Specimens were prepared from GIC and resin-modified GIC (RMGI), and divided into 3 groups based on surface protection: (1) no coating (NC), (2) Equia coat coating (EC), and (3) un-filled adhesive coating (AD). All specimens were then placed in distilled water for 24 h. Surface hardness (n = 10) was evaluated on a Vickers hardness testing machine. Wear resistance (n = 10) was evaluated after subjecting the specimen to thermocycling for 10,000 cycles using a chewing simulator. Data were analyzed using a one-way ANOVA and the Kruskal-Wallis test. Surface hardness was highest in the NC groups, followed by the EC and AD groups. The wear depth of GI + NC was significantly higher than that of all RMGI groups. EC did not significantly lower the wear depth compared to AD. Based on these results, it was concluded that although EC does not increase the surface microhardness of GIC, it can increase the wear resistance.
Keywords
Surface protection; Glass ionomer cement; Resin-modified glass ionomer cement; Surface hardness; Wear;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Park JH, Park S, Lim HP, et al. : Antagonist wear of three CAD/CAM anatomic contour zirconia ceramics. J Prosthet Dent, 111:20-29, 2014.   DOI
2 Leirskar J, Nordbo H, Mount GJ, Ngo H : The influence of resin coating on the shear punch strength of a high strength auto-cure glass ionomer. Dent Mater, 19:87-91, 2003.   DOI
3 McLean JW, Wilson AD : The clinical development of the glass-ionomer cements. i. Formulations and properties. Aust Dent J, 22:31-36, 1977.   DOI
4 Mitra SB, Kedrowski BL : Long-term mechanical properties of glass ionomers. Dent Mater, 10:78-82, 1994.   DOI
5 Gemalmaz D, Yoruc B, Ozcan M, Alkumru HN : Effect of early water contact on solubility of glass ionomer luting cements. J Prosthet Dent, 80:474-478, 1998.   DOI
6 Uno S, Finger WJ, Fritz U : Long-term mechanical characteristics of resin-modified glass ionomer restorative materials. Dent Mater, 12:64-69, 1996.   DOI
7 Miyazaki M, Moore BK, Onose H : Effect of surface coatings on flexural properties of glass ionomers. Eur J Oral Sci, 104:600-604, 1996.   DOI
8 Faraji F, Heshmat H, Banava S : Effect of protective coating on microhardness of a new glass ionomer cement: Nanofilled coating versus unfilled resin. J Conserv Dent, 20:260-263, 2017.   DOI
9 Kim KH, Ong JL, Okuno O : The effect of filler loading and morphology on the mechanical properties of contemporary composites. J Prosthet Dent, 87:642-649, 2002.   DOI
10 Shinkai K, Taira Y, Suzuki M, et al. : Effect of filler size and filler loading on wear of experimental flowable resin composites. J Appl Oral Sci, 26:e20160652, 2018.   DOI
11 Croll TP, Nicholson JW : Glass ionomer cements in pediatric dentistry: review of the literature. Pediatr Dent, 24:423-429, 2002.
12 Frencken JE : The ART approach using glass-ionomers in relation to global oral health care. Dent Mater, 26:1-6, 2010.   DOI
13 Zhao J, Weng Y, Xie D : A novel high-wear-resistant glassionomer cement for class I and class II restorations. Eur J Oral Sci, 117:86-89, 2009.   DOI
14 Kunzelmann KH, Burkle V, Bauer C : Two-body and threebody wear of glass ionomer cements. Int J Paediatr Dent, 13:434-440, 2003.   DOI
15 Hotta M, Hirukawa H, Yamamoto K : Effect of coating materials on restorative glass-ionomer cement surface. Oper Dent, 17:57-61, 1992.
16 Mount GJ, Makinson OF : Glass-ionomer restorative cements: clinical implications of the setting reaction. Oper Dent, 7:134-141, 1982.
17 Bonifacio CC, Werner A, Kleverlaan CJ : Coating glass-ionomer cements with a nanofilled resin. Acta Odontol Scand, 70:471-477, 2012.   DOI
18 Catelan A, Briso AL, Sundfeld RH, Dos Santos PH : Effect of artificial aging on the roughness and microhardness of sealed composites. J Esthet Restor Dent, 22:324-330, 2010.   DOI
19 Marquezan M, Osorio R, Ciamponi AL, Toledano M : Resistance to degradation of bonded restorations to simulated caries-affected primary dentin. Am J Dent, 23:47-52, 2010.
20 Francci C, Deaton TG, Bawden JW, et al. : Fluoride release from restorative materials and its effects on dentin demineralization. J Dent Res, 78:1647-1654, 1999.   DOI
21 Lohbauer U : Dental Glass Ionomer Cements as Permanent Filling Materials? - Properties, Limitations Future Trends. Materials (Basel), 3:76-96, 2010.   DOI
22 Jung YS, Lee JW, Huh JB, et al. : A study on the in-vitro wear of the natural tooth structure by opposing zirconia or dental porcelain. J Adv Prosthodont, 2:111-115, 2010.   DOI
23 van Duinen RN, Kleverlaan CJ, Feilzer AJ, et al. : Early and long-term wear of 'fast-set' conventional glass-ionomer cements. Dent Mater, 21:716-720, 2005.   DOI
24 de Gee AJ, van Duinen RN, Werner A, Davidson CL : Early and long-term wear of conventional and resin-modified glass ionomers. J Dent Res, 75:1613- 1619, 1996.   DOI
25 Lacy AM, Young DA : Modern concepts and materials for the pediatric dentist. Pediatr Dent, 18:469-478, 1996.
26 Kim GS, Kim YK : The effect of various surface coatings on microleakage and microhardness of light-cured glass ionomer restoration. J Korean Acad Pediatr Dent, 24:495-510, 1997.
27 Kishore G, Sai-Sankar AJ, Sai-krishna VS, et al. : Comparative Evaluation of Fluoride Releasing Ability of Various Restorative Materials after the Application of Surface Coating Agents - An In-vitro Study. J Clin Diagn Res, 10:ZC38-ZC41, 2016.