Browse > Article

MAXILLARY MOLAR DISTALIZATION AND PREMOLAR ALIGNMENT WITH A JONES JIG APPLIANCE: CASE REPORTS  

Jeon, Eun-Kyung (Department of Pediatric Dentistry, School of Dentistry, Seoul National University)
Hyun, Hong-Keun (Department of Pediatric Dentistry, School of Dentistry, Seoul National University)
Kim, Young-Jae (Department of Pediatric Dentistry, School of Dentistry, Seoul National University)
Kim, Jung-Wook (Department of Pediatric Dentistry, School of Dentistry, Seoul National University)
Jang, Ki-Taeg (Department of Pediatric Dentistry, School of Dentistry, Seoul National University)
Kim, Chong-Chul (Department of Pediatric Dentistry, School of Dentistry, Seoul National University)
Hahn, Se-Hyun (Department of Pediatric Dentistry, School of Dentistry, Seoul National University)
Lee, Sang-Hoon (Department of Pediatric Dentistry, School of Dentistry, Seoul National University)
Publication Information
Journal of the korean academy of Pediatric Dentistry / v.37, no.4, 2010 , pp. 497-504 More about this Journal
Abstract
The treatment of Class II non-extraction cases, especially when premolar space is lost due to premature loss of the deciduous molars, usually requires distal movement of the maxillary molars. The Jones jig appliance is a non-compliant intraoral appliance and is effective for the distalization of the maxillary molars. It has unfavorable side-effects, however, so caution is needed to adjust the appliance and select appropriate cases. We reported four cases in which maxillary molar distalizations were concomitant with the alignment of palatally erupted premolars.
Keywords
Jones jig appliance; Upper molar distalization; Ectopic eruption; Alignment of premolar;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Bondemark L, Kurol J : Repelling magnets versus superelastic Ni-Ti coils in simultaneous distal movement of maxillary first and second molars. Angle Orthod, 63:189-198, 1994.
2 Blechman AM, Smiley H : Magnetic force in orthodontics. Am J Orthod, 74:435-443, 1978.   DOI   ScienceOn
3 Haydar S, Uner O : Comparison of Jones jig molar distalization appliance with extraoral traction. Am J Orthod Dentofacial Orthop, 117:49-53, 2000.   DOI   ScienceOn
4 Sfondrini MF, Cacciafesta V, Sfondrini G : Upper molar distalization: a critical analysis. Orthod Craniofac Res, 5(2):114-126, 2002.   DOI   ScienceOn
5 Daskalogiannakis J, McLachlan KR : Canine retraction with rare earth magnets: an investigation into the validity of the constant force hypothesis. Am J Orthod Dentofacial Orthop, 109:489-495, 1996.   DOI   ScienceOn
6 Gianelly A : Distal movement of the maxillry molars. Am J Orthod Dentofacial Orthop, 114:67-72, 1998.
7 Al-Faleh L : Intraoral maxillary molar distalization: A review. Parkistan oral & dental J, 29:302-310.
8 Patel MP, Janson G, Henriques JF, et al. : Comparative distalization effects of Jones jig and pendulum appliances. Am J Orthod Dentofacial Orthop, 135:336-342, 2009.   DOI   ScienceOn
9 Antonarakis GS, Kiliaridis S : Maxillary molar distalization with noncompliance intramaxillary appliances in Class II malocclusion. a systematic review. Angle Orthod, 78:1133-1140, 2008.   DOI
10 Becker A : The orthodontic treatment of impacted teeth. 2nd ed., Informa Healthcare, UK, 183-184, 2007.
11 Kalra V : The K-loop molar distalizing appliance. J Clin Orthod, 29:298-301, 1995.
12 Mavropoulos A, Sayinsu K, Allaf F, et al. : Noncompliance unilateral maxillary molar distalization. Angle Orthod, 76:382-387, 2006.
13 Ghosh J, Nanda RS : Evaluation of an intraoral maxillary molar distalization technique. Am J Orthod Dentofacial Orthop, 110:639-646, 1996.   DOI   ScienceOn
14 Runge ME, Martin JT, Bukai F : Analysis of rapid maxillary molar distal movement without patient cooperation. Am J Orthod Dentofacial Orthop, 115:153-157, 1999.   DOI   ScienceOn
15 Kinzinger GS, Eren M, Diedrich PR : Treatment effects of intraoral appliances with conventional anchorage designs for non-compliance maxillary molar distalization. A literature review. Eur J Orthod, 30:558-571, 2008.   DOI   ScienceOn
16 Kurol J, Bjerklin K : Treatment of children with ectopic eruption of the maxillary first permanent molar by cervical traction. Am J Orthod, 86:483-492, 1984.   DOI   ScienceOn
17 Gulati S, Kharbanda OP, Parkash H : Dental and skeletal changes after intraoral molar distalization with sectional jig assembly. Am J Orthod Dentofacial Orthop, 114:319-327, 1998.   DOI   ScienceOn
18 이상민, 김종범, 한세현 : Jones Jig를 이용한 하악 제1대 구치 원심이동의 치험례. 대한소아치과학회지, 24:543-548, 1997.
19 Gianelly AA, Bednar J, Dietz VS : Japanese Ni-Ti coils used to move molars distally. Am J Orthod Dentofacial Orthop, 99:564-566, 1991.   DOI   ScienceOn
20 Gianelly AA, Bonds PW, Johnson WM : Distalization of molars with repelling magnets. J Clin Orthod, 22:40-44, 1998.
21 Hilgers JH : The pendulum appliance for Class II noncompliance therapy. J Clin Orthod, 26:706-14, 1992.
22 Jones RD, White JM : Rapid Class II molar correction with an open-coil jig. J Clin Orthod, 26:661-664, 1992.
23 Akin E, Gurton AU, Sagdic D : Effects of a segmented removable appliance in molar distalization. Eur J Orthod, 28:65-73, 2006.
24 이현정, 김영재, 김정욱 등 : Pendulum 장치를 이용한 상악 대구치의 원심이동 증례. 대한소아치과학회지, 35:523-530, 2008.   과학기술학회마을
25 Brickman CD, Sinha PK, Nanda RS : Evaluation of the Jones jig appliance for distal molar movement. Am J Orthod Dentofacial Orthop, 118:526-534, 2000.   DOI   ScienceOn