Browse > Article
http://dx.doi.org/10.3340/jkns.2010.47.2.128

The Variable Ellipsoid Modeling Technique as a Verification Method for the Treatment Planning System of Gamma Knife Radiosurgery  

Hur, Beong-Ik (Department of Neurosurgery & Medical Research Institute, Pusan National University Hospital, Pusan National University School of Medicine)
Choi, Byung-Kwan (Department of Neurosurgery & Medical Research Institute, Pusan National University Hospital, Pusan National University School of Medicine)
Sung, Soon-Ki (Department of Neurosurgery & Medical Research Institute, Pusan National University Hospital, Pusan National University School of Medicine)
Cho, Won-Ho (Department of Neurosurgery & Medical Research Institute, Pusan National University Hospital, Pusan National University School of Medicine)
Cha, Seung-Heon (Department of Neurosurgery & Medical Research Institute, Pusan National University Hospital, Pusan National University School of Medicine)
Choi, Chang-Hwa (Department of Neurosurgery & Medical Research Institute, Pusan National University Hospital, Pusan National University School of Medicine)
Publication Information
Journal of Korean Neurosurgical Society / v.47, no.2, 2010 , pp. 128-133 More about this Journal
Abstract
Objective : The secondary verification of Leksell Gamma Knife treatment planning system (LGP) (which is the primary verification system) is extremely important in order to minimize the risk of treatment errors. Although prior methods have been developed to verify maximum dose and treatment time, none have studied maximum dose coordinates and treatment volume. Methods : We simulated the skull shape as an ellipsoid with its center at the junction between the mammillary bodies and the brain stem. The radiation depths of the beamlets emitted from 201 collimators were calculated based on the relationship between this ellipsoid and a single beamlet expressed as a straight line. A computer program was coded to execute the algorithm. A database system was adopted to log the doses for $31{\times}31{\times}31$ or 29,791 matrix points allowing for future queries to be made of the matrix of interest. Results : When we compared the parameters in seven patients, all parameters showed good correlation. The number of matrix points with a dose higher than 30% of the maximal dose was within ${\pm}\;2%$ of LGP. The 50% dose volume, which is generally the target volume, differs maximally by 4.2%. The difference of the maximal dose ranges from 0.7% to 7%. Conclusion : Based on the results, the variable ellipsoid modeling technique or variable ellipsoid modeling technique (VEMT) can be a useful and independent tool to verify the important parameters of LGP and make up for LGP.
Keywords
Gamma knife radiosurgery; Treatment planning system; Quality assurance;
Citations & Related Records

Times Cited By Web Of Science : 0  (Related Records In Web of Science)
Times Cited By SCOPUS : 2
연도 인용수 순위
  • Reference
1 Shields JR, Medearis AL, Bear MB : Fetal head and abdominal circumferences : effect of profile shape on the accuracy of ellipse equations. J Clin Ultrasound 15 : 241-244, 1987   DOI   ScienceOn
2 Beck J, Berndt A : An algorithm for independent verification of Gamma Knife treatment plans. Med Phys 31 : 2780-2784, 2004   DOI   ScienceOn
3 Tsai JS, Engler MJ, Rivard MJ, Mahajan A, Borden JA, Zheng Z : A formalism for independent checking of Gamma Knife dose calculations. Med Phys 28 : 1842-1849, 2001   DOI   ScienceOn
4 Zhang P, Dean D, Wu QJ, Sibata C : Fast verification of Gamma Knife treatment plans. J Appl Clin Med Phys 1 : 158-164, 2000   DOI   ScienceOn
5 Maitz AH, Wu A, Lunsford LD, Flickinger JC, Kondziolka D, Bloomer WD : Quality assurance for gamma knife stereotactic radiosurgery. Int J Radiat Oncol Biol Phys 32 : 1465-1471, 1995   DOI   ScienceOn
6 Marcu SM, Wu QJ, Pillai K, Weinhous MS : GammaPlan-Leksell Gamma Knife radiosurgery treatment planning verification method. Med Phys 27 : 2146-2149, 2000   DOI   ScienceOn
7 Jin JY, Drzymala R, Li Z : A simple method of independent treatment time verification in gamma knife radiosurgery using integral dose. Med Phys 31 : 3337-3344, 2004   DOI   ScienceOn