Browse > Article

Using Coagulant and Activated Carbon as Pretreatment for Membrane Fouling Control in MBR (Membrane Bioreactor)  

Kim, Dong-Ha (국민대학교 공대 건설시스템공학부)
Publication Information
Journal of Korean Society of Water and Wastewater / v.20, no.1, 2006 , pp. 122-127 More about this Journal
Abstract
The aim of this study was to investigate the characteristics of membrane fouling caused by soluble organic materials in a membrane bioreactor process. For the removal of filterable organic materials (FOC) smaller than $1{\mu}m$, coagulants and activated carbon were added. A membrane bioreactor using a submerged $17{\mu}m$ metal sieve was operated in laboratory scale to examine the possibility of membrane fouling control. As the dosage of GAC and coagulant increased, the residual FOC concentration decreased and the permeate flow rate increased markedly. The permeate flux increased with an increased PACl addition at the range from 0 to 50 mg/l. At coagulant dosage of 27mg/l, the removal of FOC was about 46% and the flux increased to 3.5 times compared to the case without PACl addition. The permeate flux increased gradually with an increase in GAC dosage. At GAC dosage of 50mg/L, the permeate flux was about 2 times higher compared that for raw water. The particle in the range of $0.1{\sim}1.0{\mu}m$ were removed effectively by the addition of GAC and coagulant. Higher osage of GAC and coagulant, led to higher removal of FOC. A different set of experiments was also performed to investigate the effect of pretreatment on the permeation ability of MBR system using the metal sieve membrane. After 40 hours of operation, the permeate flux was about 1,000 ($L/m^2-hr$), which is 20 times higher compared to the results in literature. It is likely that combined pretreatment using coagulant and activated carbon was the most effective to resolve membrane fouling problems. Moreover, the continuous operations could be successful by applying this pretreatment method.
Keywords
membrane; fouling; MBR; coagulant; activated carbon;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Bura. R, M. Cheung, B. Liao, J. Finlayson, B.C. Lee, I.G. Droppo, G.G. Leppard and S.N. Liss (1998) Composition of extracellular polymeric substances in activated sludge floc matrix, Wat. Sci. Tech. 37, 325-333
2 Gan Q., R.W. Field, M.R. Bird, R. England, J.A. Howell, M.T. McKechine, C.L. O'Shaugessy (1997) Beer clarification by cross-flow microfiltration: fouling mechanisms and flux enhancement, Chem. Eng. Res. Des., 75, 3-8   DOI   ScienceOn
3 Wiesner M.R., Hackney J., Sethi S., Jacangelo J.G. and Laine J.-M (1994) Cost estimates for membrane filtration and conventional treatment, J. Am. Water Works. Assoc., 86, 33-41
4 Adham S.S., Snoeyink V.L., Clark M.M. and Bersillon J.-L. (1991) Predicting and verifying organics removal by PAC in an UF system, J. Am. Water Works. Assoc., 83, 81-91   DOI
5 Kim J.-S., Lee S.-J., Yoon S.-H. and Lee C.-H. (1996) Competitive adsorption of trace organics on membrane and powdered activated carbon in powdered activated carbonultrafiltration system, Water Sci. Technol., 34, 223-229
6 Mukai. T, K., Murakami, K. Takimoto, T. Kohno, and M. Okada (1997) Ultrafiltration behavior of extracellular and metabolic products in activated sludge system with UF separation process, Proc of Asian Water quality 97, 1499-1504
7 Pribazari M., Badriyha B.N. and Ravindran V. (1992) MFPAC for treating waters contaminated with natural and synthetic organics, J. Am. Water Works. Assoc., 84, 95-103   DOI
8 Adham S.S., Jacangelo J.G. and Laine J.-M. (1996) Characteristics and costs of MF and UF plants, J. Am. Water Works. Assoc., 88, 22-31
9 Mulder M. (1996) Basic Principles of Membrane Technology, Kluwer Ascdemic Publishers