Abstract
This study examined the dynamic characteristics of the gate to identify the optimal gate installation direction according to the installation direction. A 1:31 scale model was constructed for a 47.5m prototype gate using acrylic. The scaled weights were tuned by adding lead weights. The first step was to measure the natural frequencies of the model gates, and compare them with finite-element analysis of the prototypes as a calibration. The scaled model was tested in a 1.6 m wide concrete flume for two orientations to determine the effects of the gate orientation on structural vibrations. Vertical vibrations were measured under a range of operational conditions, including a range of bottom opening heights and different upstream and downstream water levels. For large bottom opening heights in the normal direction, relatively large vibrations were induced by vortices shed at the plate bottom that would strike the horizontal truss member. This phenomenon was avoided in the reverse direction. For small bottom opening heights in the normal direction, these vibrations were caused by a suction force that developed at the gate bottom. The gate model in the reverse direction was preferred because of its low overall vibrational response under general gate opening and flow level combinations.
Keywords
Model test; 47.5m gate; Normal direction; Reverse direction; Truss-type lift gate; Vibration amplitude;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 Lee, S. H., "Model Tests Study on Flow-induced Vibration of Tainter gate in Estuary Sulices (I)", Journal of the korean society of agricultural, vol. 46, no. 1, pp. 27-34. 2004.
2 Lee, S. H., Hahm, H. G., Ryu, G. S., "Dynamic Characteristics of the Long Span Truss-Type Lift Gate by Model Test." Journal of the korean society of agricultural engineers, vol. 57, no. 36, pp. 117-123. 2015.   DOI
3 Kolkman, P. A., Flow-induced Gate Vibrations. Prevention of Self-excitation. Delft Hydraulics laboratory, Publication, no. 164, pp. 1-162, 1976.
4 Gajanan, M. S., Harry, G. H., Richard, N. W., and Saeed, M., Structural Modeling and Experimental Techniques, Prentice-Hall Civil Engineering and Engineering Mechanics Series, pp. 1-60, 1983.
5 Thang, N.D., "Gate Vibrations due to Unstable Flow Separation", Journal of Hydraulics Engineering, vol. 116, no. 3, 1990.
6 Lee, S. H., Cheung, J. W., Kim, K. N., Hahm H. G., Jung, K. S., Characteristics on the Temperature Distribution in Steel Girder Bridge by using Gauge Measurement, Journal of e korean Society of steel Construction, vol, 23, no. 3, pp. 285-286, 2011.