Abstract
This study assessed the feasibility of odor removal by the application of Bacillus sp. that has many advantages in sewage treatment to sewage sludge. The NH3 removal rates in the treatment of primary sludge using only aeration were measured at 24, 48, and 72 hours of treatment and the results were 12.5 %, 12 %, and 42.1 %, respectively. The NH3 removal rates of a reactor injected with BIO-CLOD made by solidifying Bacillus sp. concentrated 10 % together with other substances were measured after 24, 48, and 72 hours of treatment and the results were 43 %, 70 %, and 81 % respectively. In the cases where the Bacillus sp. cultured in NB medium was injected into the primary sludge reactor to reach injection rates of 0 %, 1.7 %, 3.3 %, and 6.7(v/v%), the TVOC removal rates measured when 72 hours had passed after the injection were 59 %, 71 %, 88 %, and 98 % respectively, which were higher than the NH3 removal rates as the NH3 removal rates measured at the same time were shown to be 29 %, 25 %, 31 %, and 48 %, respectively. In the sludge dewaterability conducted with various Bacillus sp. injection concentrations, a Bacillus sp. concentration of 4(v/v%) was considered to be suitable. The Bacillus sp. concentrations and reduction in the bad odor substances were correlated with each other. The results showed that aeration and Bacillus sp. injection will assist biological oxidation so that the bad odor substances can be removed. Based on the SRF values of the primary sludge and digested sludge, in which Alum and PAC were used, the appropriate amount of Alum aggregate reagent was judged to be 500 mg/L, and when PAC was used, 6 mg/L was judged to be appropriate.
Keywords
Bacillus sp.; sludge dewaterability; odor removal; primary sludge; SRF;
Citations & Related Records
Times Cited By KSCI : 6  (Citation Analysis)
연도 인용수 순위
1 Ministry of Environment, Environ. statistics year book, Available : [accessed 1 July 2016] http://www.me.go.kr/home/web/policy_data/read.do?menuId=10264&seq=6671.
2 Ko B. C., Lee J. K., Lee Y. S., Lee M. G., Kam S. K., "A study odor emission characteristics of domestic sewage treatment facilities using composite odor concentration and hydrogen sulfide concentration" J. of the Environ Sciences , 21(11), pp. 1379-1388, 2012. DOI: http://dx.doi.org/10.5322/jes.2012.21.11.1379   DOI
3 Eom T. K., "The study for the advanced efficient of SBR process using Bacillus sp." J. of Korean Soc. of Water Sci. and Tech.., 19(6), pp. 11-19, 2011.
4 Kim E. H., Cho Y. J., Park S. J., Shin K. S., Yim S. B., Jung J. K., " Advanced wastewater treatment process using rotating activated Bacillus contactor(RABC)" J. of Korean Soc. on Water Quality, 20(2), pp.190-195, 2004.
5 Lee S. H., Son H. H., "Sedimentation and EPS production by the change of dissolved oxygen concentration for the aeration tank to treat wastewater with Bacillus sp." J. of the Koera Academia-Industrial Cooperation Society, 8(3), pp.627-631, 2007.
6 Ko B. C., Park Y. H., Kim D. I., Lee M. G., Kam S. K., "Odor removal characteristics of biofilters in domestic sewage treatment facilities analyzing composite odor and odor quotient" J. of the Environ Science, 22(1), pp. 109-117, 2013. DOI: http://dx.doi.org/10.5322/jes.2013.22.1.109   DOI
7 Sung I. W., "The Study on the Odor Removal of Digested Sludge using BIO-CLOD" J. the Koera Academia-Industrial Cooperation Society, 16(12), pp.8665-8672, 2015. DOI: http://dx.doi.org/10.5762/KAIS.2015.16.12.8665   DOI
8 Jung B. G., Seong D. H., Bin J. I., Lee B. H., "Removal of odorfrom food wastes by nightsoil treatment sludge including Bacillus" J. of Water Treatment, 22(5), pp.49-58, 2014.
9 Lim D. J., Lim K. H., "Characteristics on the incubation of sulfur compound-oxidizing strains separated for the removal of malodor" Korean Chem. Eng. Res., 47(6), pp. 788-794, 2009.
10 Choi I., Lee H. J., Shin J. D., Kim H. O., "Evaluation of effectiveness of five odor reducing agents for sewer system odors using an on-line total reduced sulfur analyzer", pp.16892-16906, Sensors, 2012. DOI: http://dx.doi.org/10.3390/s121216892   DOI
11 Huh M., Park C. K., "Odor control for the nightsoil treatment plant by a biological submerged deodorator with air lift aeration", J. of Korean Soc of Environ Eng, 11(1), pp. 1-11, 1989.
12 Park O. H., Chun S. N., "A study on deordorization technology employing microorganisms(I) - Effect of temperature on hydrogen sulfide removal efficiency in activated sludge tank" J. of Korean Soc. of Environ Eng, 12(2), pp. 59-69, 1990.
13 Park H. J., "Removal characteristics of total Coliforms in rotating activated Bacillus contactor process" pp. 39-40, Hong Ik University, 2003.