Browse > Article

Numerical Simulation of Ventilation in the Storage Hall of Tripitaka Koreana at Haein Temple in Case of Building Rearrangement  

Hur, Nahm-Keon (Department of Mechanical Engineering, Sogang University)
Lee, Myung-Sung (Graduate School, Sogang University)
Yang, Sung-Jin (Graduate School, Sogang University)
Publication Information
Korean Journal of Air-Conditioning and Refrigeration Engineering / v.19, no.5, 2007 , pp. 379-385 More about this Journal
Abstract
In the present study, ventilation flow in the Janggyeongpan-Jeon at Haein temple in case of building rearrangement has been investigated numerically. To achieve more accurate results, detailed shapes such as buildings and the window grills are modeled and tree canopy model is adopted to account for the effect of trees in the computation. Wind velocities as boundary condition are taken from meteorological statistical data. The numerical results show that ventilation flow distributions at Janggyeongpan-Jeon in case of building rearrangement are nearly similar to those before rearrangement.
Keywords
Ventilation; Flow analysis; Haein temple; Tripitaka Koreana; Storage hall; CFD;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Hur, N., Jeong, S. and Kim, T. G., 1998, Analysis of natural ventilation flow in the storage hall of Tripitaka Koreana at Haein temple, Proceedings of the SAREK Winter Annual Meeting, pp.509-514
2 http://news.buddhapia.com/news/BNC000/BNC0008243.html
3 Mochida, A., et al., 2006, Optimization of tree canopy model for CFD prediction of wind environment at pedestrian level, The 4th Symposium CWE, Vol. 4, pp. 561-564
4 Lee, S. H., 1994, Haein temple architectural plan, Hansaem
5 Climate information data from the management system of Korea Meteo-rological Administration, Mountain Gaya, 2002-2005
6 STAR-CD manual version 3.24, 2004, Computational Dynamics Ltd