Lower Flammability Limits of Flammable Refrigerants According to ASTM E681-04 Standard  

Park, Ki-Jung (Graduate School of Mechanical Engineering, Inha University)
Woo, Seung-Gyoo (Graduate School of Mechanical Engineering, Inha University)
Jung, Dong-Soo (Department of Mechanical Engineering, Inha University)
Publication Information
Korean Journal of Air-Conditioning and Refrigeration Engineering / v.19, no.10, 2007 , pp. 726-734 More about this Journal
Abstract
In this study, lower flammability limits (LFLs) of three hydrocarbon refrigerants (R600a, R290, R1270) and two hydrofluorocarbon refrigerants (R152a, R32) and DME (RE170) are measured by the method proposed by ASTM E681-04 Standard. Flammability tests are carried out at three temperatures of $23^{\circ}C,\;60^{\circ}C\;and\;100^{\circ}C$ and relative humidity 50%. Test results show that the present data for isobutane and propane obtained at $23^{\circ}C$ are similar to those found in the literature, confirming indirectly the reliability of the present test method and facility. For propylene, R152a, and R32, LFLs found in the literature differ considerably. Especially, the deviation of LFL of propylene is more than 30% among the literature data. The present data for propylene, R152a, and R32 agree with either of the data sets available. As the temperature increases from $23^{\circ}C\;to\;100^{\circ}C$, LFLs of all refrigerants tested decrease. LFLs of most refrigerants tested in this study at $60^{\circ}C$ decrease by $0.1{\sim}0.3%$ as compared to those at $23^{\circ}C$. Also LFLs of most refrigerants tested in this study at $100^{\circ}C$ decrease by $0.1{\sim}0.3%$ as compared to those at $60^{\circ}C$.
Keywords
Flammability; Flammable refrigerants; Lower flammability limits(LFL);
Citations & Related Records
연도 인용수 순위
  • Reference
1 Richard, R., 1998, Refrigerant flammability testing in large volume vessels, ARTI MCLR final Report, DOE/CE/23810-87, Arlington, Va. : Air-Conditioning and Refrigeration Technology Institute(ARTI)
2 Int. Energy Agency's Heat Pump Center, Informative fact sheet, 2002, Hydrocarbons as refrigerants in residential heat pumps and air-conditioners
3 Ghodbane, M, 1999, An investigation of R152a and hydrocarbon refrigerants in mobile air conditioning, International Congress and Exposition, Detroit, Michigan, 1999-01-0874
4 Didion D. A., 1994, Private Communication, US National Institute of Standards and Technology, Gaithersburg, MD
5 ASHRAE, 1989, Designation and safety classification of refrigerants, ASHRAE Standard, ANSI/ASHRAE Standard 34-1989
6 Du Pont, 2004, Material safety data sheet for HFC-152a, Du Pont Fluoroproducts, Wilmington, DE 19898, USA
7 ASTM, 1985, Standard test method for concentration limits of flammability of chemicals, ASTM E681-85, Philadelphia: American Society for Testing and Materials
8 Choi, T. Y. and Kim, M. S., 1995, Flammability test of R32/R134a refrigerant mixture, Proceeding of the SAREK 1995 Summer Annual Conference, pp.269-274
9 Smith, N. D., Ratanaphruks, K., Tufts, M. and Ng, A. S., 1993, R-245ca: A potential far-term alternative for R-11, ASHRAE Journal, Vol. 35, No.2, pp.19-23
10 Kruse H., 1996, The stats of the art of the hydrocarbon technology in household refrigeration, Proc. of the Int. Conferences on Ozone Protection Technologies, Washington, DC, pp. 179- 188
11 BOC Gases, 2002, Material safety data sheet for, Halocarbon-32, BOC Group, Murray Hill, NJ 07974, USA
12 Richard, R. G. and Shankland, I. R., 1992, Flammabiity of alternative refrigerants. ASHRAE Journal, Vol. 34, No.4, pp.20-24
13 Matheson, 2003, Material safety data sheet for 1,1-difluoroethane, Matheson Tri-Gas, Parsippany, NJ 07054, USA
14 Heinonen, E. W., Tapscott, R. E. and Crawford, F. R., 1994, Methods development for measuring and classifying flammability/combustibility of refrigerants, ARTI MCLR final Report, DOE/CE/2381O-50, Albuquerque, Va. : Air-Conditioning and Refrigeration Technology Institutet(ARTI)
15 U. L., 1994, Standard for safety-refrigerants, UL Standard 2182, Northbrook, Ill.: Underwriters Laboratories
16 ASTM, 2004, Standard test method for concentration limits of flammability of chemicals, ASTM E681-04, Philadelphia: American Society for Testing and Materials
17 Jung, D., Park, B. and Lee, H., 1999, Evaluation of supplementary/retrofit refrigerants for automobile air-conditioners charged with CFC12, Int. J. Refrigeration, Vol. 22, pp. 558-568   DOI   ScienceOn
18 Braker, W. and Mossman, A., 1980, Matheson gas data book, sixth edition, Matheson company, Lyndhurst, NJ 07071, USA
19 Molina, M. J. and Rowland, F. S., 1974, Stratospheric sink for chlorofluoromethanes : chlorine atom catalyzed destruction of ozones, Nature, Vol. 249, pp. 810-812   DOI
20 Montreal protocol on substances that de-plete the ozone layer, 1989, Final Act, United Nations Environment Programme
21 ASHRAE, 1992, Number designation and safety classification of refrigerants, ASHRAE Standard, ANSVASHRAE Standard 34-1992
22 Wilson, D. P. and Richard, R G., 2002, Determination of refrigerant lower flammability limits in compliance with proposed addendum p to standard 34, ASHRAE Transactions, Vol. 108, Part 2, pp. 739-756
23 Du Pont, 2001, Material safety data sheet for Dymel, Du Pont Fluoroproducts, Wilmington, DE 19898, USA