Browse > Article
http://dx.doi.org/10.7236/JIWIT.2011.11.6.143

Research of IP Based Monitoring System for Foul/Waste Water Disposal(Treatment) Plant  

Kim, Dae-Ho (서울과학기술대학교 매체공학과)
Kang, Yong-Sik (서울과학기술대학교 매체공학과)
Lee, Joo-Young (서울과학기술대학교 매체공학과)
Moon, Kyung-Hwan (서울과학기술대학교 매체공학과)
Lim, Yun-Sik (여주대학 방송영상제작과)
Kim, Wan-Sik (LIG 넥스원)
Shin, Jae-Kwon (파이브텍 R&D 센터)
Gu, Ja-Wan (파이브텍 R&D 센터)
Kim, Jin-Tae (파이브텍 R&D 센터)
Cho, Ju-Phil (국립군산대학교 전파공학과)
Cha, Jae-Sang (서울과학기술대학교 매체공학과)
Publication Information
The Journal of the Institute of Internet, Broadcasting and Communication / v.11, no.6, 2011 , pp. 143-150 More about this Journal
Abstract
In this paper, we intend to implement system of the automation of foul/waste water disposal plant by using processed sensor data. We designed the model of communication system based on wireless indoor environment, implemented monitoring and control system based on IP. In the implemented monitoring system, it is possible to control and monitor through not only PC but also smart device(tablet PC, smart phone) anywhere, if WEB is connected.
Keywords
IP; WEB; Sensor; Foul water; Waste water;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 Spanjers H., Olsson G. and Klapwijk A. (1993) Determining influent short-term biochemical oxygen demand by combined respirometry and estimation. Wat. Sci. Tech., 28(11-12), 401-414.
2 Demuynck C., Vanrolleghem P.A., Mingneau C., Liessens J. and Verstraete W. (1994) NDBEPR process optimization in SBRs: Reduction of external carbon source and oxygen supply. Wat. Sci. Tech., 30(4), 169-179.
3 Bourgeois W., Burgess J.E. and Stuetz R.M. (2001) On-line monitoring of wastewater quality: a review. J. Chem. Tech. Biotech., 76, 337-348.   DOI   ScienceOn
4 Lee D. S. and Vanrolleghem P. A. (2002) On-line monitoring equipment for wastewater treatment processes: state of the art, AutMoNet 2002, Vienna, Austrialia.
5 Larsen L.H., Damgaard L.R., Kjaer T., Stenstrom T., Lynggaard-Jensen A. and Revsbech N.P. (2000) Fast responding biosensor for on-line determination of nitrate/nitrite in activated sludge. Wat. Res., 34, 2463-2468.   DOI   ScienceOn
6 De Clercq J., Devisscher M., Boonen I., Vanrolleghem P.A. and Defrancq J. (2002) A new one-85
7 dimensional clarifier model verificaiton using full-scale experimental data. In: Proceedings 3rd IWA World Water Congress. April 7-12, Melbourne, Australia.
8 이대성, 우승한, "생물학적 하 폐수처리 공정에서의 실시간 모니터링 센서", DICER TechInfo Part I, Vol. 5, No. 5, pp68-86, 2006.
9 안준수, 박욱근, 조정호, "공장폐수가 혼합된 하수처리장의 하수처리 특성", 한국산학기술학회논문지, Vol. 12, pp. 3341-3352, 2011.
10 박진관, 임해진, 남시병, "웹 환경에서 임베디드 시스템을 이용한 VOC센서 원격 신호 모니터링 시스템 개발", 한국산학기술학회논문지, Vol. 12, pp. 375-383, 2011.