Effectiveness and Safety of the Tempofilter II to Prevent the Occurrence of Pulmonary Thromboembolism in Patients with Lower Extremity Deep Vein Thrombosis |
Baek, Byung-Hyun
(Department of Radiology, Chonnam National University Hospital, Chonnam National University, Medical School)
Jung, Min-Young (Department of Radiology, Chonnam National University Hospital, Chonnam National University, Medical School) Oh, Hyun-Jun (Department of Radiology, Chonnam National University Hospital, Chonnam National University, Medical School) Jang, Nam-Kyu (Department of Radiology, Chonnam National University Hwasun Hospital, Chonnam National University, Medical School) Kim, Jae-Kyu (Department of Radiology, Chonnam National University Hospital, Chonnam National University, Medical School) Lee, Ho-Kyun (Department of Surgery, Chonnam National University Hospital, Chonnam National University, Medical School) |
1 | Rossi P, Arata FM, Bonaiuti P, Pedicini V. Fatal outcome in atrial migration of the tempofilter. Cardiovasc Intervent Radiol 1999;22: 227-231 DOI ScienceOn |
2 | Ferris EJ, McCowan TC, Carver DK, McFarland DR. Percutaneous inferior vena caval filters: follow-up of seven designs in 320 patients. Radiology 1993;188:851-856 |
3 | Decousus H, Leizorovicz A, Parent F, Page Y, Tardy B, Girard P, et al. A clinical trial of vena caval filters in the prevention of pulmonary embolism in patients with proximal deep-vein thrombosis. N Engl J Med 1998;338:409-415 DOI ScienceOn |
4 | Bovyn G, Gory P, Reynaud P, Ricco JB. The Tempofilter: a multicenter study of a new temporary caval filter implantable for up to six weeks. Ann Vasc Surg 1997;11:520-528 DOI ScienceOn |
5 | Bovyn G, Ricco JB, Reynaud P, Le Blanche AF. Long-duration temporary vena cava filter: a prospective 104-case multicenter study. J Vasc Surg 2006;43:1222-1229 DOI ScienceOn |
6 | 노병석, 조한일, 이염식, 방동호, 박성훈, 이영환. 하지 심부정맥혈전증의 혈관 내 치료 동안 예방목적의 하대정맥필터 설치. 대한영상의학회지 2009;61:149-153 |
7 | Carson JL, Kelley MA, Duff A, Weg JG, Fulkerson WJ, Palevsky HI, et al. The clinical course of pulmonary embolism. N Engl J Med 1992;326:1240-1245 DOI ScienceOn |
8 | Matchett WJ, Jones MP, McFarland DR, Ferris EJ. Suprarenal vena caval filter placement: follow-up of four filter type in 22 patients. J Vasc Interv Radiol 1998;9:588-593 DOI |
9 | Stein PD, Alnas M, Skaf E, Kayali F, Siddiqui T, Olson RE, et al. Outcome and complications of retrievable inferior vena cava filters. Am J Cardiol 2004;94:1090-1093 DOI ScienceOn |
10 | Imberti D, Bianchi M, Farina A, Siragusa S, Silingardi M, Ageno W. Clinical experience with retrievable vena cava filters: results of a prospective observational multicenter study. J Thromb Haemost 2005;3:1370-1375 DOI ScienceOn |
11 | 성민현, 김영환, 이상권, 최진수, 김미정, 구자현 등. 유동성 하대정맥혈전증 환자에서 Gunther Tulip Filter의 설치 및 제거. 대한영상의학회지 2005;52:325-331 |
12 | Yamagami T, Yoshimatsu R, Matsumoto T, Nishimura T. Prophylactic implantation of inferior vena cava filter during endovascular therapies for deep venous thrombosis of the lower extremity: is it necessary? Acta Radiol 2008;49:391-397 DOI ScienceOn |