Browse > Article

Magnetic Resonance Imaging of a Current Density Component  

Oh, Suk-Hoon (Graduate School of East-West Medical Science, Kyung Hee University)
Park, Tae-Seok (Graduate School of East-West Medical Science, Kyung Hee University)
Han, Jae-Yong (Graduate School of East-West Medical Science, Kyung Hee University)
Lee, Soo-Yeol (Graduate School of East-West Medical Science, Kyung Hee University)
Publication Information
Journal of Biomedical Engineering Research / v.25, no.3, 2004 , pp. 183-188 More about this Journal
Abstract
Magnetic resonance current density imaging (MRCDI) is a useful method for measuring electrical current density distribution inside an object. To avoid object rotations during the conventional MRCDI scans, we have reconstructed current density component images by applying a spatial filter to the magnetic field data measured both inside and outside the object. To measure the magnetic field outside the object with MRI, we immersed the object in a water tank. To evaluate accuracy of the current density imaging, we have made a conductivity phantom with a corresponding finite element method model. We have compared the experimentally obtained current density images with the ones calculated by the finite element method. The average errors of the reconstructed current density images were 6.6 ∼ 45.4 % when the injected currents were 1 ∼ 24 mA. We expect that the current density component imaging technique can be used in diverse biomedical applications such as electrical therapy system developments and biological electrical safety analysis.
Keywords
Current density component imaging; MRI; Electrical conductivity; Spatial filter; Electrical safety;
Citations & Related Records
연도 인용수 순위
  • Reference
1 /
[ Grimnes S(et al.) ] / Bioimpedance & bioelectricity
2 Reconstruction of two-dimensional current distribution from tangential MCG measurement /
[ Kandori A(et al.) ] / Phys. Med. Biol.   DOI   ScienceOn
3 A high-temperature rf SQUID system for magnetocardiography /
[ Zeng XH(et al.) ] / Meas. Sci. Technol.   DOI   ScienceOn
4 Measurement of nonuniform current density by magnetic resonance /
[ Scott GC(et al.) ] / IEEE Trans. Med. Imag.
5 Vactor analysis of current pathways in post-mortem pig torso /
[ Yoon RS(et al.) ] / Proc. ISMRA 2314
6 A single current density component imaging by MRCDI without subject rotations /
[ Oh SH(et al.) ] / Magn. Reson. Imag.   DOI   ScienceOn
7 Measurement of electrical current density distribution within the tissues of the head by magnetic resonance imaging /
[ Gamba HR(et al.) ] / Med. Biol. Eng. Comp.   DOI   ScienceOn
8 /
[ Ghiglia DC(et al.) ] / Two dimensional phase unwrapping: Theory, algorithms and softwrae
9 Electric current density imaging of bone by MRI /
[ Beravs K(et al.) ] / Magn. Reson. Imag.   DOI   ScienceOn
10 Electric current density imaging of mice tumors /
[ Sersa I(et al.) ] / Magn. Reson. Med.   DOI   ScienceOn
11 Sensitivity of magnetic-resonance current-density imaging /
[ Scott GC(et al.) ] / J. Magn. Reson.
12 A preliminary study on temperature change monitoring using the MR current density imaging technique /
[ Khang HS(et al.) ] / Meas. Sci. Technol.
13 Using a magnetometer to image a two-dimensional current distribution /
[ Roth BJ(et al.) ] / J.Appl. Phys.   DOI
14 Biomagnetic Fourier Imaging /
[ Alvarez RE ] / IEEE Trans. Med. Imag.   DOI   ScienceOn