Browse > Article
http://dx.doi.org/10.9718/JBER.2019.40.5.143

Fabrication of Ex vivo Cornea Model for a Drug Toxicity Evaluation  

Kim, Seon-Hwa (Interdisciplinary Program of Biomedical Mechanical & Electrical Engineering, Pukyong National University)
Park, Sang-Hyug (Interdisciplinary Program of Biomedical Mechanical & Electrical Engineering, Pukyong National University)
Publication Information
Journal of Biomedical Engineering Research / v.40, no.5, 2019 , pp. 143-150 More about this Journal
Abstract
To evaluate the toxicity of ophthalmic drug, the Draize test and Bovine Corneal Opacity and Permeability (BCOP) test commonly used. In Draize test, experimental animals were under stress and pain due to long-term exposure of drug. In addition, regarding physiological functions, animal model is not perfectly reflected a human eye condition. Although some models such as $EpiOcular^{TM}$, HCE model, LabCyte Cornea-Model, and MCTT $HCE^{TM}$ were already presented advanced cornea ex-vivo model to replace animal test. In this sense, cornea tissue structure mimicked ex-vivo toxicity model was fabricated in this study. The corneal epithelial cells (CECs) and keratocytes (CKs) isolated from rabbit eyeball were seeded on non-patterned silk film (n-pSF) and patterned silk film (pSF) at $32,500cells/cm^2$ and $6,500cells/cm^2$. Sequentially, n-pSF and pSF were stacked to mimic a multi-layered stroma structure. The thickness of films was about $15.63{\mu}m$ and the distance of patterns was about $3{\mu}m$. H&E stain was performed to confirm the cell proliferation on silk film. F-actin of CKs was also stained with Phalloidin to observe the cytoskeletal alignment along with patterns of the pSF. In the results, CECs and CKs were shown the good cell attachment on the n-pSF and pSFs. Proliferated cells expressed the specific phenotype of cornea epithelium and stroma. In conclusion, we successfully established the ex-vivo cornea toxicity model to replace the eye irritation tests. In further study, we will set up the human ex-vivo cornea toxicity model and then will evaluate the drug screening efficacy.
Keywords
Eye irritation animal test; Tissue engineered cornea; Ex-vivo toxicity model; Bio fabrication;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Gil ES, Park SH, Marchant J. Response of human corneal fibroblasts on silk film surface patterns. Macromol Biosci. 2010;10(6):664-73.   DOI
2 DelMonte DW and Kim T. Anatomy and physiology of the cornea. J Cataract Refract Surg. 2011;37(3):588-98.   DOI
3 Dohlman CH. The function of the corneal epithelium in health and disease. Invest Ophthalmol. 1971;10(6):381-407.
4 Draize JH, Woodard G and Calvery HO. Methods for the study of irritation and toxicity of substances applied topically to the skin and mucous membranes. J Pharmacol Exp Ther. 1944;82(3):377-90.
5 Vinardell M and Mitjans M. Alternative methods for eye and skin irritation tests: an overview. J Pharm Sci. 2008;97(1):46-59.   DOI
6 Bosshard E. Review on skin and mucous-membrane irritation tests and their application. Food Chem Toxicol. 1985;23(2):149-54.   DOI
7 Katoh M, Hamajima F, Ogasawara T. Establishment of a new in vitro test method for evaluation of eye irritancy using a reconstructed human corneal epithelial model, LabCyte CORNEA-MODEL. Toxicol In Vitro. 2013;27(8):2184-92.   DOI
8 Jung KM, Lee SH, Ryu YH. A new 3D reconstituted human corneal epithelium model as an alternative method for the eye irritation test. Toxicol In Vitro. 2011;25(1):403-10.   DOI
9 Doucet O, Lanvin M, Thillou C. Reconstituted human corneal epithelium: a new alternative to the Draize eye test for the assessment of the eye irritation potential of chemicals and cosmetic products. Toxicol In Vitro. 2006;20(4):499-512.   DOI
10 Kundu B, Kurland NE, Bano S. Silk proteins for biomedical applications: Bioengineering perspectives. Prog Polym Sci. 2014;39(2):251-67.   DOI
11 Wilhelmus KR. The Draize eye test. Surv Ophthalmol. 2001;45(6):493-515.   DOI
12 Wilson SE, Liu JJ and Mohan RR. Stromal-epithelial interactions in the cornea. Prog Retin Eye Res. 1999;18(3):293-309.   DOI
13 Lawrence BD, Marchant JK, Pindrus MA. Silk film biomaterials for cornea tissue engineering. Biomaterials. 2009;30(7):1299-308.   DOI
14 Gosselin EA, Torregrosa T, Ghezzi CE. Multi-layered silk film coculture system for human corneal epithelial and stromal stem cells. J Tissue Eng Regen Med. 2018;12(1):285-95.   DOI
15 Wang S, Ghezzi CE, Gomes R. In vitro 3D corneal tissue model with epithelium, stroma, and innervation. Biomaterials. 2017;112:1-9.   DOI
16 Lee M, Hwang J-H and Lim K-M. Alternatives to in vivo Draize rabbit eye and skin irritation tests with a focus on 3D reconstructed human cornea-like epithelium and epidermis models. Toxicol Res. 2017;33(3):191.   DOI
17 Stern M, Klausner M, Alvarado R. Evaluation of the EpiOcularTM tissue model as an alternative to the Draize eye irritation test. Toxicol In Vitro. 1998;12(4):455-61.   DOI