Breast-dedicated Positron Emission Tomography Systems  

Yoon, Hyun-Suk (Department of Nuclear Medicine, Seoul National University College of Medicine)
Lee, Chan-Mi (Department of Nuclear Medicine, Seoul National University College of Medicine)
Ito, Mikiko (Department of Nuclear Medicine, Seoul National University College of Medicine)
Kwon, Sun-Il (Department of Nuclear Medicine, Seoul National University College of Medicine)
Kim, Soo-Mee (Department of Nuclear Medicine, Seoul National University College of Medicine)
Ko, Guen-Bae (Department of Nuclear Medicine, Seoul National University College of Medicine)
Lee, Dong-Soo (Department of Nuclear Medicine, Seoul National University College of Medicine)
Hong, Seong-Jong (Department of Radiological Science, Eulji University)
Lee, Jae-Sung (Department of Nuclear Medicine, Seoul National University College of Medicine)
Publication Information
Journal of Biomedical Engineering Research / v.31, no.4, 2010 , pp. 259-268 More about this Journal
Abstract
Breast cancer is the most prevalent woman cancer, and its prevalence rate is increasing rapidly. It is necessary to develop the breast-dedicated positron emission tomography (PET) or positron emission mammography (PEM) systems with high resolution and sensitivity to improve the accuracy of diagnosis of breast cancer. Therefore, it is necessary to develop the high-end PET system technologies, such as the measurement of depth-of-interaction (DOI) and fully digitalized data acquisition, to establish high performance breast imaging systems. In this paper, recent technical advances in breast-dedicated PET imaging systems will be reviewed.
Keywords
breast imaging; positron emission tomography (PET); positron emission mammography (PEM);
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 S. L. Bowen, S. R. Cherry, J. M. Boone, and R. D. Badawi, "Monte Carlo simulation study of several camera designs for the PET component of a dedicated breast PET/CT scanner," Eur. J. Nucl. Med. Mol. Imaging, vol. 33, no., pp. S117-S117, 2006.   DOI   ScienceOn
2 S. J. Lee, C. H. Baek, Y. H. Chung, Y. Choi, and W. Lee, "A cross-stack quasi-monolithic detector with DOI capability for a small animal PET," J. Korean Phys. Soc., vol. 54, no. 6, pp. 2429-2434, 2009.   DOI   ScienceOn
3 W. W. Moses, "Trends in PET imaging," Nucl. Instrum. Meth. A, vol. 471, no. 1-2, pp. 209-214, 2001.   DOI
4 Y. H. Chung, Y. Choi, G. Cho, Y. S. Choe, K. H. Lee, and B. T. Kim, "Characterization of dual layer phoswich detector performance for small animal PET using Monte Carlo simulation," Phys. Med. Biol., vol. 49, no. 13, pp. 2881-2890, 2004.   DOI   ScienceOn
5 B. Ravindranath, S. H. Maramraju, S. S. Junnarkar, S. S. Southekal, S. P. Stoll, J. F. Pratte, et al., "A Simultaneous PET/MRI breast scanner based on the RatCAP," IEEE Nuclear Science Symposium Conference Record, 2008.
6 C. G. Berman, "Recent advances in breast-specific imaging," Cancer Control, vol. 14, no. 4, pp. 338-349, 2007.   DOI
7 M. Furuta, et al. "Basic evaluation of a C-shaped breast PET scanner," IEEE Nuclear Science Symposium Conference Record, 2009.
8 N. Avril, C. A. Rose, M. Schelling, J. Dose, W. Kuhn, S. Bense, et al., "Breast imaging with positron emission tomography and fluorine-18 fluorodeoxyglucose: use and limitations," J. Clin. Oncol., vol. 18, no. 20, pp. 3495-3502, 2000.   DOI
9 S. E. Derenzo, W. W. Moses, H. G. Jackson, B. T. Turko, J. L. Cahoon, A. B. Geyer, and T. Vuletich, "Initial Characterization of a position-sensitive photodiode BGO detector for PET," IEEE Trans. Nucl. Sci., vol. 36, no. 1, pp. 1084-1089, 1989.   DOI   ScienceOn
10 J. S. Kim, J. S. Lee, K. C. Im, S. J. Kim, S. Y. Kim, D. S. Lee, and D. H. Moon, "Performance measurement of the microPET focus 120 scanner," J. Nucl. Med., vol. 48, no. 9, pp. 1527-1535, 2007.   DOI   ScienceOn
11 S. J. Hong, S. Il Kwon, M. Ito, G. S. Lee, K. S. Sim, K. S. Park, J. T. Rhee, and J. S. Lee, "Concept verification of three-layer DOI detectors for small animal PET," IEEE Trans. Nucl. Sci., vol. 55, no. 3, pp. 912-917, 2008.   DOI
12 J. S. Lee, "Technical advances in current PET and hybrid imaging systems," Open Nucl. Med. J., 2010. [In press]
13 R. Fontaine, F. Belanger, N. Viscogliosi, H. Semmaoui, M. A. Tetrault, J. B. Michaud, C. Pepin, J. Cadorette, and R. Lecomte, "The hardware and signal processing architecture of LabPET (TM), a small animal APD-based digital PET scanner," IEEE Trans. Nucl. Sci., vol. 56, no. 1, pp. 3-9, 2009.   DOI
14 G. Muehllehner, "Letter: Resolution limit of positron cameras," J. Nucl. Med., vol. 17, no. 8, pp. 757-758, 1976.
15 G. C. Wang, J. S. Huber, W. W. Moses, J. Qi, and W. S. Choong, "Characterization of the LBNL PEM camera," IEEE Trans. Nucl. Sci., vol. 53, no. 3, pp. 1129-1135, 2006.   DOI
16 M. C. Abreu, D. Aguiar, E. Albuquerque, F. G. Almeida, P. Almeida, P. Amaral, et al., "Clear-PEM: A PET imaging system dedicated to breast cancer diagnostics," Nucl. Instrum. Meth. A, vol. 571, no. 1-2, pp. 81-84, 2007.   DOI
17 M. C. Abreu, J. D. Aguiar, F. G. Almeida, P. Almeida, P. Bento, B. Carrico, et al., "Design and evaluation of the Clear-PEM scanner for positron emission mammography," IEEE Trans. Nucl. Sci., vol. 53, no. 1, pp. 71-77, 2006.   DOI
18 Z. Cheng, O. P. De Jesus, M. Namavari, A. De, J. Levi, J. M. Webster, et al., "Small-animal PET imaging of human epidermal growth factor receptor type 2 expression with site-specific 18F-labeled protein scaffold molecules," J. Nucl. Med., vol. 49, no. 5, pp. 804-813, 2008.   DOI   ScienceOn
19 W. H. Lee, and I. R. Yoo, "The role of fluorodeoxyglucose PET in the management of breast cancer," Hanyang Medical Review. vol. 28, no. 4, pp. 43-51, 2007.
20 F. Benard, and E. Turcotte, "Imaging in breast cancer: Single-photon computed tomography and positron-emission tomography," Breast Cancer Res., vol. 7, no. 4, pp. 153-162, 2005.   DOI   ScienceOn
21 H. S. Kim, S. M. Kim, H. R. Cho, and J. S. Lee, "Comparison of MAP reconstruction algorithms and prior functions for gap compensation in animal PET," Fall Symposium of Korean Society of Medical and Biological Engineering. 2009.
22 Y. Shao, R. W. Silverman, R. Farrell, L. Cirignano, R. Grazioso, K. S. Shah, et al., "Design studies of a high resolution PET detector using APD arrays," IEEE Trans. Nucl. Sci., vol. 47, no. 3, pp. 1051-1057, 2000.   DOI   ScienceOn
23 Y. F. Yang, Y. B. Wu, J. Y. Qi, S. S. James, H. N. Du, P. A. Dokhale, K. S. Shah, R. Farrell, and S. R. Cherry, "A prototype PET scanner with DOI-encoding detectors," J. Nucl. Med., vol. 49, no. 7, pp. 1132-1140, 2008.   DOI   ScienceOn
24 H. R. Cho, S. M. Kim, and J. S. Lee, "Parameter analysis for relaxed OS-SPS algorithm for image reconstruction," Spring Symposium of Korean Society of Medical and Biological Engineering. 2009.
25 S. M. Ahn, S. M. Kim, and J. S. Lee, "ART reconstruction of limited-angle data using constrained, total-variation minimization," Spring Symposium of Korean Society of Medical and Biological Engineering. 2010.
26 B. J. Pichler, M. S. Judenhofer, C. Catana, J. H. Walton, M. Kneilling, R. E. Nutt, S. B. Siegel, C. D. Claussen, and S. R. Cherry, "Performance test of an LSO-APD detector in a 7-T MRI scanner for simultaneous PET/MRI," J. Nucl. Med., vol. 47, no. 4, pp. 639-647, 2006.
27 H. P. Schlemmer, B. J. Pichler, M. Schmand, Z. Burbar, C. Michel, R. Ladebeck, et al., "Simultaneous MR/PET imaging of the human brain: feasibility study," Radiology, vol. 248, no. 3, pp. 1028-1035, 2008.   DOI   ScienceOn
28 M. Ito, J. S. Lee, S. Il Kwon, G. S. Lee, B. Hong, K. S. Lee, et al., "A four-layer DOI detector with a relative offset for use in an animal PET system," IEEE Trans. Nucl. Sci., vol. 57, no. 3, pp. 976-981, 2010.   DOI
29 G. Delso, and S. Ziegler, "PET/MRI system design," Eur. J. Nucl. Med. Mol. Imaging, vol. 36 Suppl 1, no., pp. S86-92, 2009.   DOI
30 H. F. Wehrl, M. S. Judenhofer, S. Wiehr, and B. J. Pichler, "Pre-clinical PET/MR: technological advances and new perspectives in biomedical research," Eur. J. Nucl. Med. Mol. Imaging, vol. 36 Suppl 1, no., pp. S56-68, 2009.   DOI
31 Y. H. Chung, S. J. Lee, C. H. Baek, and Y. Choi, "New design of a quasi-monolithic detector module with DOI capability for small animal PET," Nucl. Instrum. Meth. A, vol. 593, no. 3, pp. 588-591, 2008.   DOI   ScienceOn
32 J. S. Lee, M. Ito, K. S. Sim, B. Hong, K. S. Lee, J. Muhammad, et al., "Investigation of solid-state photomultipliers for positron emission tomography scanners," J. Korean Phys. Soc., vol. 50, no. 5, pp. 1332-1339, 2007.   DOI   ScienceOn
33 S. J. Hong, I. C. Song, M. Ito, S. I. Kwon, G. S. Lee, K. S. Sim, K. S. Park, J. T. Rhee, and J. S. Lee, "An investigation into the use of Geiger-mode solid-state photomultipliers for simultaneous PET and MRI acquisition," IEEE Trans. Nucl. Sci., vol. 55, no. 3, pp. 882-888, 2008.   DOI
34 J. S. Lee, and S. J. Hong Geiger-mode avalanche photodiodes for PET/MRI. In: Iniewski K, eds. Electronic Circuits for Radiation Detection. CRC Press LLC, 2010, pp. 179-200.
35 S. I. Kwon, J. S. Lee, H. S. Yoon, M. Ito, G. B. Ko, J. Y. Choi, S-H. Lee, I. C. Song, J. M. Jeong, D. S. Lee, and S. J. Hong, "Development of small animal PET prototype using a Geiger-mode APD: Initial results of phantom and animal imaging studies", J. Nucl. Med., [Submitted]
36 J. H. Jung, Y. Choi, K. J. Hong, W. Hu, J. Kang, B. J. Min, S. H. Shin, H. K. Lim, Y. S. Huh, and E. J. Kim, "Development of a position decoder circuit for PET consisting of GAPD arrays," Nucl. Instrum. Meth. A, vol. 621, no. 1-3, pp. 310-315, 2010.   DOI
37 R. R. Raylman, S. Majewski, M. F. Smith, J. Proffitt, W. Hammond, A. Srinivasan, et al., "The positron emission mammography/tomography breast imaging and biopsy system (PEM/PET): design, construction and phantom-based measurements," Phys. Med. Biol., vol. 53, no. 3, pp. 637-653, 2008.   DOI   ScienceOn
38 M. Ito, J. S. Lee, M. J. Park, K. S. Sim, and S. J. Hong, "Design and simulation of a novel method for determining depth-of- interaction in a PET scintillation crystal array using a single- ended readout by a multi-anode PMT," Phys. Med. Biol., vol. 55, no. 13, pp. 3827-3841, 2010.   DOI   ScienceOn
39 W. W. Moses, S. E. Derenzo, C. L. Melcher, and R. A. Manente, "Room-temperature LSO PIN photodiode PET detector module that measures depth of interaction," IEEE Trans. Nucl. Sci., vol. 42, no. 4, pp. 1085-1089, 1995.   DOI   ScienceOn
40 W. W. Moses, and J. Qi, "Fundamental limits of positron emission mammography," Nucl. Instrum. Meth. A, vol. 497, no. 1, pp. 82-89, 2003.   DOI   ScienceOn
41 J. Y. Qi, R. M. Leahy, S. R. Cherry, A. Chatziioannou, and T. H. Farquhar, "High-resolution 3D Bayesian image reconstruction using the microPET small-animal scanner," Phys. Med. Biol., vol. 43, no. 4, pp. 1001-1013, 1998.   DOI   ScienceOn
42 S. Surti, and J. S. Karp, "Design considerations for a limited angle, dedicated breast, TOF PET scanner," Phys. Med. Biol., vol. 53, no. 11, pp. 2911-2921, 2008.   DOI   ScienceOn
43 K. Kitamura, and H. Kudo. "MAP-EM reconstruction using uniform background template for limited-angle PEM," IEEE Nuclear Science Symposium Conference Record, 2008.