Browse > Article
http://dx.doi.org/10.9718/JBER.2010.31.3.177

In vivo Evaluation of Flow Estimation Methods for 3D Color Doppler Imaging  

Yoo, Yang-Mo (Department of Electronic Engineering and Interdisciplinary Program of Integrated Biotechnology)
Publication Information
Journal of Biomedical Engineering Research / v.31, no.3, 2010 , pp. 177-186 More about this Journal
Abstract
In 3D ultrasound color Doppler imaging (CDI), 8-16 pulse transmissions (ensembles) per each scanline are used for effective clutter rejection and flow estimation, but it yields a low volume acquisition rate. In this paper, we have evaluated three flow estimation methods: autoregression (AR), eigendecomposition (ED), and autocorrelation combined with adaptive clutter rejection (AC-ACR) for a small ensemble size (E=4). The performance of AR, ED and AC-ACR methods was compared using 2D and 3D in vivo data acquired under different clutter conditions (common carotid artery, kidney and liver). To evaluate the effectiveness of three methods, receiver operating characteristic (ROC) curves were generated. For 2D kidney in vivo data, the AC-ACR method outperforms the AR and ED methods in terms of the area under the ROC curve (AUC) (0.852 vs. 0.793 and 0.813, respectively). Similarly, the AC-ACR method shows higher AUC values for 2D liver in vivo data compared to the AR and ED methods (0.855 vs. 0.807 and 0.823, respectively). For the common carotid artery data, the AR provides higher AUC values, but it suffers from biased estimates. For 3D in vivo data acquired from a kidney transplant patient, the AC-ACR with E=4 provides an AUC value of 0.799. These in vivo experiment results indicate that the AC-ACR method can provide more robust flow estimates compared to the AR and ED methods with a small ensemble size.
Keywords
Ultrasound imaging; 3D color Doppler imaging; autoregression; eigendecomposition; autocorrelation; adaptive clutter rejection;
Citations & Related Records
연도 인용수 순위
  • Reference
1 M. E. Allam and J. F. Greenleaf, "Isomorphism between pulsed-wave Doppler ultrasound and direction-of-arrival estimation-part I: basic principles," IEEE Trans. Ultrason. Ferroelect. Freq. Control, vol. 43, no. 5, pp. 911-922, 1996.   DOI   ScienceOn
2 P. J. Vaitkus, R. S. C. Cobbold, and K. W. Johnston, "A new time-domain narrowband velocity estimation technique for Doppler ultrasound flow imaging-part II: comparative performance assessment," IEEE Trans. Ultrason. Ferroelect. Freq. Control, vol. 45, no. 4, pp. 955-971, 1998.   DOI   ScienceOn
3 Y. M. Yoo, S. Sikdar, K. Karadayi, O. Kolokythas, and Y. Kim, "Adaptive clutter rejection for 3D color Doppler imaging: preliminary clinical study," Ultrasound Med. Biol., vol. 34, no. 8, pp. 121-1231, 2008.
4 Marple SL. Digital Spectral Analysis with Applications. Prentice Hall, Englewood Cliffs, NJ, 1987.
5 Stoica P, Moses R. Introduction to Spectral Analysis. Prentice Hall, Upper Saddle River, NJ, 1997.
6 Y. M. Yoo, R. Managuli, and Y. Kim, "An adaptive clutter filtering for ultrasound color flow imaging," Ultrasound Med. Biol., vol. 29, no. 9, pp. 1311-1320, 2003.   DOI   ScienceOn
7 Y. B. Ahn and S. B. Park, "Estimation of mean frequency and variance of ultrasonic Doppler signal by using second-order autoregressive model," IEEE Trans. Ultrason. Ferroelect. Freq. Control, vol. 38, no. 3, pp. 172-182, 1991.   DOI   ScienceOn
8 L.A.F. Ledoux, P.J. Brands and A.P.G. Hoeks, "Reduction of the clutter component in Doppler ultrasound signals based on singular value decomposition: a simulation study," Ultrason. Imaging, vol. 19, no. 1, pp. 1-18, 1997.   DOI   ScienceOn
9 D. E. Kruse and K. W. Ferrara, "A new high resolution color flow system using an eigendecomposition-based adaptive filter for clutter rejection," IEEE Trans. Ultrason. Ferroelect. Freq. Control, vol. 49, no. 12, pp. 1739-1754, 2002.   DOI
10 T. Loupas and W. N. McDicken, "Low-order complex AR models for mean and maximum frequency estimation in the context of Doppler color flow mapping," IEEE Trans. Ultrason. Ferroelect. Freq. Control, vol. 37, no. 6, pp. 590-601, 1990.   DOI   ScienceOn
11 M. E. Allam, R. R. Kinnick, and J. F. Greenleaf, "Isomorphism between pulsed-wave Doppler ultrasound and direction-of-arrival estimation-part II: experimental results," IEEE Trans. Ultrason. Ferroelect. Freq. Control, vol. 43, no. 5, pp. 923-935, 1996.   DOI   ScienceOn
12 P. J. Vaitkus, and R. S. C. Cobbold, "A new time-domain narrowband velocity estimation technique for Doppler ultrasound flow imaging-part I: theory," IEEE Trans. Ultrason. Ferroelect. Freq. Control, vol. 45, no. 4, pp. 939-954, 1998.   DOI   ScienceOn
13 H. Tsujino, M. Jones, T. Shiota, J.X. Qin, L. A. Cardon, A. J. Morehead, A. D. Zetts, F. Bauer, M. Stiges, X. Hang, N. L. Greenberg, J. A. Panza, and J. D. Thomas, "Impact of temporal resolution on flow quantification by real-time 3D color Doppler echocardiography: numerical modeling and animal validation study," Comput. Cardiol., vol. 27, pp. 761-764, 2000.
14 D.H. Pretorius, T. R. Nelson, and J. S. Jaffe, "3-dimensional sonographic analysis based on color flow Doppler and gray scale image data: a preliminary report," J. Ultrasound Med., vol. 11, no. 5, pp. 225-232, 1992.   DOI
15 J. Pemberton, L. Hui, M. Young, X. Li, A. Kenny, and D. J. Sahn, "Accuracy of 3-dimensional color Doppler-derived flow volumes with increasing image depth," J Ultrasound Med., vol. 24, no. 8, pp. 1109-1115, 2005.   DOI
16 H. Torp, "Clutter rejection filters in color flow imaging: a theoretical approach," IEEE Trans. Ultrason. Ferroelect. Freq. Control, vol. 44, no. 2, pp. 417-424, 1997.   DOI   ScienceOn
17 S. Bjaerum, H. Torp, and K. Kristoffersen, "Clutter filters adapted to tissue motion in ultrasound color flow imaging," IEEE Trans. Ultrason. Ferroelect. Freq. Control, vol. 49, no. 6, pp. 693-704, 2002.   DOI
18 R. Chaoui, J. Hoffmann, and K. S. Heling, "Three-dimensional (3D) and 4D color Doppler fetal echocardiography using spatio-temporal image correlation (STIC)," Ultrasound Obstet. Gynecol., vol. 23, no. 6, pp. 535-545, 2004.   DOI   ScienceOn
19 C. Kasai, K. Namekawa, A. Koyano, and R. Omoto, "Real-time two-dimensional blood flow imaging using an autocorrelation techniques," IEEE Trans. Sonics. Ultrason., vol. 32, no. 3, pp. 458-463, 1985.   DOI
20 R. D. Simone, G. Glombitza, C. F. Vahl, J. Albers, H. P. Meinzer, and S. Hagl, "Three-dimensional color Doppler: a new approach for quantitative assessment of mitral regurgitant jets," J. Am. Soc. Echocardiogr., vo. 12, no. 3, pp. 173-185, 1999.   DOI   ScienceOn
21 U. Herberg, H. Goldberg, and J. Breuer, ''Three- and four-dimensional freehand fetal echocardiography: a feasibility study using a hand-held Doppler probe for cardiac gating," Ultrasound Obstet. Gynecol., vol. 25, no. 4, pp. 362-371, 2005.   DOI   ScienceOn
22 P. S. Mehwald, R. A. Rusk, Y. Mori, X. N. Li, A. D. Zetts, M. Jones, and D. J. Sahn, "A validation study of aortic stroke volume using dynamic 4-dimensional color Doppler: an in vivo study," J. Am. Soc. Echocardiogr., vol. 15, no. 10, pp. 1045-1050, 2002.   DOI   ScienceOn