1 |
Chung, S.S., Lee, C.S., and Kang, C.S., "Lumbar total disc replacement using ProDisc II: a prospective study with a 2-year minimum follow-up." J Spinal Disord Tech, 19(6): pp. 411-5, 2006.
DOI
ScienceOn
|
2 |
Shim, C.S., Shin, H.D., and Lee, S.H., "Posterior avulsion fracture at adjacent vertebral body during cervical disc replacement with ProDisc-C: a case report." J Spinal Disord Tech, 20(6): pp. 468-72, 2007.
DOI
ScienceOn
|
3 |
Park, C.K., K.S. Ryu, and W.H. Jee, "Degenerative changes of discs and facet joints in lumbar total disc replacement using ProDisc II: minimum two-year follow-up." Spine, 33(16): pp. 1755-61, 2008.
DOI
ScienceOn
|
4 |
Bertagnoli, R., Yue, J.J., Shah, R.V., Nanieva, R., Pfeiffer, F., Fenk-Mayer, A., Kershaw, T. , and Husted, D.S., "The treatment of disabling single-level lumbar discogenic low back pain with total disc arthroplasty utilizing the Prodisc prosthesis: a prospective study with 2-year minimum follow-up." Spine, 30(19): pp. 2230-6, 2005.
DOI
ScienceOn
|
5 |
McAfee, P., Cunninghan, BW, Shimamoto, N., Sefter, JC, Dmitriev, A.E., and Fedder, I.L., "SB Charite disc replacement: Biologic ingrowth using a non-human promate model," in The Artificial Disc, P. McAfee, Hochschuler,SH, Buttner-Janz,K, Editor., Springer-Verlag: New York. 2003 pp. 63-71.
|
6 |
Siegele, D., Soltesz,U., "Numerical Invesigation of the influence of implant shape on stress distribution in the jaw bone." The international Journal of Oral & Maxillofacial Implant 4(4): pp. 333-340, 1989.
|
7 |
Overaker, D.W., Langrana, N.A., and Cuitino, A.M., "Finite element analysis of vertebral body mechanics with a nonlinear microstructural model for the trabecular core." J Biomech Eng, 121(5): pp. 542-50, 1999.
DOI
ScienceOn
|
8 |
Hedman, T.P., Kostuik, J.P., Fernie, G.R., and Hellier, W.G., "Design of an intervertebral disc prosthesis." Spine, 16(6 Suppl): pp. S256-60, 1991.
DOI
|
9 |
Lim, J.W., Effects of artificial discs on spinal system, in Mechanical Eng. 2008, Ph.D. thesis, Hanyang Univ., Seoul., Korea
|
10 |
Andrew, P.D., Experimental and theological investigation into the effects of artificial disc implantation on the lumbar spine. 2001, Ph.D. thesis, Univ. of Iowa, Iowa., US
|
11 |
Bushelow, M., Walker, J., Coppes, J., Hinter, M., Nechtow, W., and Kaddick, C. "Comparison of wear rates:metal/UHMWPE and metal on metal total disc arthroplasty." in Proceedings of the NASS 22nd annual meeing: Spine. 2007. pp. S31-S32.
|
12 |
Murrey, D., Janssen, M., Delamarter, R., Goldstein, J., Zigler, J., Tay, B., and Darden, B., "Results of the prospective, randomized, controlled multicenter Food and Drug Administration investigational device exemption study of the ProDisc-C total disc replacement versus anterior discectomy and fusion for the treatment of 1-level symptomatic cervical disc disease." Spine J, 2008.
|
13 |
Bertagnoli, R., Yue, J.J., Fenk-Mayer, A., Eerulkar, J. ,and Emerson, J.W., "Treatment of symptomatic adjacent-segment degeneration after lumbar fusion with total disc arthroplasty by using the prodisc prosthesis: a prospective study with 2-year minimum follow up." J Neurosurg Spine, 4(2): pp. 91-7, 2006.
DOI
ScienceOn
|
14 |
Taylor, R.L., Simo, J.C., Zienkiewicz, O.C. ,Chan, A.C.H., "The patch test- A condition for assessing FEM convergence ". Int. J. Num. Mech. Engng., 22(1): pp. 39-62, 1986.
DOI
ScienceOn
|