Browse > Article
http://dx.doi.org/10.9718/JBER.2008.29.6.436

MREIT of Postmortem Swine Legs using Carbon-hydrogel Electrodes  

Minhas, Atul S. (College of Electronics and Information, Kyung Hee University)
Jeong, Woo-Chul (College of Electronics and Information, Kyung Hee University)
Kim, Young-Tae (College of Electronics and Information, Kyung Hee University)
Kim, Hyung-Joong (College of Electronics and Information, Kyung Hee University)
Lee, Tae-Hwi (College of Electronics and Information, Kyung Hee University)
Woo, Eung-Je (College of Electronics and Information, Kyung Hee University)
Publication Information
Journal of Biomedical Engineering Research / v.29, no.6, 2008 , pp. 436-442 More about this Journal
Abstract
Magnetic resonance electrical impedance tomography(MREIT) has been suggested to produce cross-sectional conductivity images of an electrically conducting object such as the human body. In most previous studies, recessed electrodes have been used to inject imaging currents into the object. An MRI scanner was used to capture induced magnetic flux density data inside the object and a conductivity image reconstruction algorithm was applied to the data. This paper reports the performance of a thin and flexible carbon-hydrogel electrode that replaces the bulky and rigid recessed electrode in previous studies. The new carbon-hydrogel electrode produces a negligible amount of artifacts in MR and conductivity images and significantly simplifies the experimental procedure. We can fabricate the electrode in different shapes and sizes. Adding a layer of conductive adhesive, we can easily attach the electrode on an irregular surface with an excellent contact. Using a pair of carbon-hydrogel electrodes with a large contact area, we may inject an imaging current with increased amplitude primarily due to a reduced average current density underneath the electrodes. Before we apply the new electrode to a human subject, we evaluated its performance by conducting MREIT imaging experiments of five swine legs. Reconstructed conductivity images of the swine legs show a good contrast among different muscles and bones. We suggest a future study of human experiments using the carbon-hydrogel electrode following the guideline proposed in this paper.
Keywords
magnetic resonance electrical impedance tomography; magnetic flux density; conductivity image; carbon-hydrogel electrode;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 E.J. Woo, S.Y. Lee, and C.W. Mun, "Impedance tomography using internal current density distribution measured by nuclear magnetic resonance", SPIE, vol. 2299, pp. 377-385, 1994   DOI
2 H.J. Kim, T.I. Oh, Y.T. Kim, B.I. Lee, E.J. Woo, J.K. Seo, S.Y. Lee, O. Kwon, C. Park, B.T. Kang, and H.M. Park, "In vivo electrical conductivity imaging of a canine brain using a 3T MREIT system", Physiol. Meas., vol. 29, pp. 1145-1155, 2008   DOI   ScienceOn
3 B.I. Lee, S.H. Oh, E.J. Woo, S.Y. Lee, M.H. Cho, O. Kwon, J.K. Seo, J.Y. Lee, and W.S. Baek, "Three-dimensional forward solver and its performance analysis in magnetic resonance electrical impedance tomography (MREIT) using recessed electrodes", Phys. Med. Biol., vol. 48, pp. 1971-1986, 2003   DOI   ScienceOn
4 S.H. Lee, J.K. Seo, C. Park, B.I. Lee, E.J. Woo, S.Y. Lee, O. Kwon, and J. Hahn, "Conductivity image reconstruction from defective data in MREIT: numerical simulation and animal experiment", IEEE Trans. Med. Imag., vol. 25, pp. 168-176, 2006   DOI   ScienceOn
5 S.H. Oh, B.I. Lee, E.J. Woo, S.Y. Lee, M.H. Cho, O. Kwon,and J.K. Seo, "Conductivity and current density image reconstruction using harmonic Bz algorithm in magnetic resonance electrical impedance tomography", Phys. Med. Biol., vol. 48, pp. 3101- 3116, 2003   DOI   ScienceOn
6 G.C. Scott, M.L.G. Joy, R.L. Armstrong, and R.M. Hankelman, "Sensitivity of magnetic resonance current density imaging", J. Magn. Reson., vol. 97, pp. 235-254, 1992
7 L.A. Geddes, and L.E. Baker, "The specific resistance of biological material: a compendium of data for the biomedical engineer and physiologist", Med. Biol. Engng., vol. 5, pp. 271-293, 1967   DOI
8 C. Gabriel, S. Gabriel, and E. Corthout, "The dielectric properties of biological tissues: I. literature survey", Phys. Med. Biol., vol. 41, pp. 2231-2249, 1996a   DOI   ScienceOn
9 S.H. Oh, B.I. Lee, E.J. Woo, S.Y. Lee, T.S. Kim, O. Kwon, and J.K. Seo, "Electrical conductivity images of biological tissue phantoms in MREIT", Physiol. Meas., vol. 26, S279-288, 2005   DOI   ScienceOn
10 T.I. Oh, W. Koo, K.H. Lee, S.M. Kim, J. Lee, S.W. Kim, J.K. Seo, and E.J. Woo, "Validation of a multi-frequency electrical impedance tomography (mfEIT) system KHU Mark1: impedance spectroscopy and time-difference imaging", Physiol. Meas., vol. 29, pp. 295-307, 2008   DOI   ScienceOn
11 C. Park, B.I. Lee, O. Kwon, and E.J. Woo, "Measurement of induced magnetic flux density using injection current nonlinear encoding (ICNE) in MREIT", Physiol. Meas., vol. 28, pp. 117-127, 2006   DOI   ScienceOn
12 S. Gabriel, R.W. Lau, and C. Gabriel, "The dielectric properties of biological tissues: II. measurements in the frequency range 10Hz to 20GHz", Phys. Med. Biol., vol. 41, pp. 2251-2269, 1996b   DOI   ScienceOn
13 E.J. Woo, J.K. Seo, and S.Y. Lee, "Magnetic resonance electrical impedance tomography (MREIT) in Holder D ed.", Electrical Impedance Tomography: Methods, History and Applications, Bristol, UK: IOP Publishing, 2005
14 S. Grimnes, and O.G. Martinsen, Bioimpedance and Bioelectricity Basics, London, UK: Academic Press, 2000
15 G.C. Scott, M.L.G. Joy, R.L. Armstrong, and R.M. Henkelman, "Measurement of nonuniform current density by magnetic resonance", IEEE Trans. Med. Imag., vol. 10, pp. 362-374, 1991   DOI   ScienceOn
16 N. Zhang, Electrical Impedance Tomography based on Current Density Imaging, Toronto, Canada: MS Thesis, Dept. of Elec. Eng, 1992
17 O. Kwon, E.J. Woo, J.R. Yoon, and J.K. Seo, "Magnetic resonance electrical impedance tomography (MREIT): simulation study of J-substitution algorithm", IEEE Trans. Biomed. Eng., vol. 49, pp. 160-167, 2002   DOI   ScienceOn
18 T.I. Oh, Y. Cho, Y.K. Hwang, S.H. Oh, E.J. Woo, and S.Y. Lee, "Improved current source design to measure induced magnetic flux density distributions in MREIT", J. Biomed. Eng. Res., vol. 27, pp. 30-37, 2006   과학기술학회마을
19 J.K. Seo, J.R. Yoon, E.J. Woo, and O. Kwon, "Reconstruction of conductivity and current density images using only one component of magnetic field measurements", IEEE Trans. Biomed. Eng., vol. 50, pp. 1121-1124, 2003   DOI   ScienceOn
20 Y.Z. Ider, and O. Birgul, "Use of the magnetic field generated by the internal distribution of injected currents for electrical impedance tomography (MR-EIT)", Elektrik, vol. 6, pp. 215-225, 1998
21 H.J. Kim, B.I. Lee, Y. Cho, Y.T. Kim, B.T. Kang, H.M. Park, S.Y. Lee, J.K. Seo, and E.J. Woo, "Conductivity imaging of canine brain using a 3 T MREIT system: postmortem experiments", Physiol. Meas., vol. 28, pp. 1341-1353, 2007   DOI   ScienceOn
22 R. Sadleir, S. Grant, S.U. Zhang, B.I. Lee, H.C. Pyo, S.H. Oh, C. Park, E.J. Woo, S.Y. Lee, O. Kwon, and J.K. Seo, "Noise analysis in MREIT at 3 and 11 Tesla field strength", Physiol. Meas., vol. 26, pp. 875-884, 2005   DOI   ScienceOn
23 S.H. Oh, B.I. Lee, T.S. Park, S.Y. Lee, E.J. Woo, M.H. Cho, O. Kwon, and J.K. Seo, "Magnetic resonance electrical impedance tomography at 3 Tesla field strength", Mag. Reson. Med., vol. 51, pp. 1292-1296, 2004   DOI   ScienceOn