Browse > Article
http://dx.doi.org/10.9718/JBER.2007.28.6.756

Investigation of Radiation Effects on the Signal and Noise Characteristics in Digital Radiography  

Kim, Ho-Kyung (School of Mechanical Engineering, Pusan National University)
Cho, Min-Kook (School of Mechanical Engineering, Pusan National University)
Graeve, Thorsten (Rad-icon Imaging Corp.)
Publication Information
Journal of Biomedical Engineering Research / v.28, no.6, 2007 , pp. 756-767 More about this Journal
Abstract
For the combination of phosphor screens having various thicknesses and a photodiode array manufactured by complementary metal-oxide-semiconductor (CMOS) process, we report the observation of image-quality degradation under the irradiation of 45-kVp spectrum x rays. The image quality was assessed in terms of dark pixel signal, dynamic range, modulation-transfer function (MTF), noise-power spectrum (NPS), and detective quantum efficiency (DQE). For the accumulation of the absorbed dose, the radiation-induced increase both in dark signal and noise resulted in the gradual reduction in dynamic range. While the MTF was only slightly affected by the total ionizing dose, the noise power in the case of $Min-R^{TM}$ screen, which is the thinnest one among the considered screens in this study, became larger as the total dose was increased. This is caused by incomplete correction of the dark current fixed-pattern noise. In addition, the increase tendency in NPS was independent of the spatial frequency. For the cascaded model analysis, the additional noise source is from direct absorption of x-ray photons. The change in NPS with respect to the total dose degrades the DQE. However, with carefully updated and applied correction, we can overcome the detrimental effects of increased dark current on NPS and DQE. This study gives an initial motivation that the periodic monitoring of the image-quality degradation is an important issue for the long-term and healthy use of digital x-ray imaging detectors.
Keywords
digital radiography; radiation effect; phosphor screen; CMOS detector; MTF; NPS; DQE; linear-systems theory; cascaded model analysis;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 J.M. Boudry and L.E. Antonuk, 'Radiation damage of amorphous silicon photodiode sensors,' IEEE Trans. Nucl. Sci., vol. 41, pp. 703-707, 1994   DOI   ScienceOn
2 B.H. Hasegawa, The Physics of Medical X-ray Imaging, Madison, Wisconsin, USA: Medical Physics Publishing, 1991
3 I.A. Cunningham, 'Applied linear-systems theory,' Chapter 2, Handbook of Medical Imaging: Vol. 1. Physics and Psychophysics (Eds. J. Beutel, H.L. Kundel, and R.L. Van Metter), Bellingham, Washington, USA: SPIE Press, 2000
4 J.T. Dobbins III, 'Image quality metrics for digital systems,' Chapter 3, Handbook of Medical Imaging: Vol. 1. Physics and Psychophysics (Eds. J. Beutel, H.L. Kundel, and R.L. Van Metter), Bellingham, Washington, USA: SPIE Press, 2000
5 E. Samei, N.T. Ranger, J.T. Dobbins III, and Y. Chen, 'Intercomparison of methods for image quality characterization. I. Modulation transfer function,' Med. Phys., vol. 33, pp. 1454-1465, 2006   DOI   ScienceOn
6 C.-S. Kim, H.K. Kim, M.K. Cho, M.H. Cheong, C.H. Lim, and J.-M. Kim, 'Computational toolset for x-ray spectral analysis,' Key Eng. Mater., vols. 321-323, pp. 1060-1065, 2006
7 J.H. Siewerdsen, L.E. Antonuk, Y. El-Mohri, J. Yorkston, W. Huang, and I.A. Cunningham, 'Signal, noise power spectrum and detective quantum efficiency of indirect-detection flat-panel imagers for diagnostic radiology,' Med. Phys., vol. 25, pp. 614-628, 1998   DOI   ScienceOn
8 R.K. Swank, 'Absorption and noise in x-ray phosphors,' J. Appl. Phys., vol. 44, pp. 4199-4203, 1973   DOI   ScienceOn
9 T.R. Oldham and F.B. McLean, 'Total ionizing dose effects in MOS oxides and devices,' IEEE Trans. Nucl. Sci., vol. 50, pp. 483-499, 2003   DOI   ScienceOn
10 W.R. Dawes Jr., Radiation effects hardening techniques, Sandia National Laboratories Report, SAND-85-0742C, 1985
11 W. Zhao, G. DeCrescenzo, and J.A. Rowlands, 'Investigation of lag and ghosting in amorphous selenium flat-panel x-ray detectors,' in Proc. SPIE, vol. 4682, 2002, pp. 9-20   DOI
12 S. Steciw, T. Stanescu, S. Rathee, and B.G. Fallone, 'Sensitivity reduction in biased amorphous selenium photoconductors,' J. Phys. D: Appl. Phys., vol. 35, pp. 2716-2722, 2002   DOI   ScienceOn
13 J.T. Dobbins III, D.L. Ergun, L. Rutz, D.A. Hinshaw, H. Blume, and D.C. Clark, 'DQE(f) of four generations of computed radiography acquisition devices,' Med. Phys., vol. 22, pp. 1581-1593, 1995   DOI   ScienceOn
14 H.K. Kim, G. Cho, Y.H. Chung, H.K. Lee, and S.C. Yoon, 'Monte Carlo studies of metal/phosphor screen in therapeutic x-ray imaging,' Nucl. Instr. Meth. A, vol. 422, pp. 713-717, 1999   DOI   ScienceOn
15 D.A. Jaffray and J.H. Siewerdsen, 'Cone-beam computed tomography with a flat-panel imager: Initial performance characterization,' Med. Phys., vol. 27, pp. 1311-1322, 2000   DOI   ScienceOn
16 J.M. Boudry and L.E. Antonuk, 'Radiation damage of amorphous silicon, thin-film, field-effect transistors,' Med. Phys., vol. 23, pp. 743-754, 1996   DOI   ScienceOn
17 K.-W. Jee, L.E. Antonuk, Y. El-Mohri,and Q. Zhao, 'System performance of a prototype flat-panel imager operated under mammographic conditions,' Med. Phys., vol. 30, pp. 1874-1890, 2003   DOI   ScienceOn
18 H.K. Kim, 'Sensor technology for digital radiography,' J. Kor. Soc. Prec. Eng., vol. 22, no. 8, pp. 7-16, 2005
19 J.A. Rowlands and S. Kasap, 'Amorphous semiconductor usher in digital x-ray imaging,' Phys. Today, vol. 50, pp. 24-30, 1997
20 T. Graeve and G. Weckler, 'High-resolution CMOS imaging detector,' in Proc. SPIE, vol. 4320, 2001, pp. 68-76   DOI
21 H. Fujita, D.Y. Tsai, T. Itoh, K. Doi, J. Morishita, K. Ueda, and A. Ohtsuka, 'A simple method for determining the modulation transfer function in digital radiography,' IEEE Trans. Med. Imag., vol. 11, pp. 34-39, 1992   DOI   ScienceOn
22 M.J. Flynn and E. Samei, 'Experimental comparison of noise and resolution for 2k and 4kstorage phosphor radiography systems,' Med. Phys., vol. 26, pp. 1612-1623, 1999   DOI   ScienceOn
23 H.K. Kim, 'Generalized cascaded model to assess noise transfer in scintillator-based x-ray imaging detectors,' Appl. Phys. Lett., vol. 89, p. 233504, 2006
24 M. Bigas, E. Cabruja, J. Forest, and J. Salvi, 'Review of CMOS image sensors,' Microelectronics Journal, vol. 37, pp. 433-451, 2006   DOI   ScienceOn
25 S.C. Lee, H.K. Kim, I.K. Chun, M.H. Cho, S.Y. Lee, and M.H. Cho, 'A flat-panel detector based micro-CT system: Performance evaluation for small-animal imaging,' Phys. Med. Biol., vol. 48, pp. 4173-4185, 2003   DOI   ScienceOn
26 W. Zhao and J.A. Rowlands, 'Digital radiology using active matrix readout of amorphous selenium: Theoretical analysis of detective quantum efficiency,' Med. Phys., vol. 24, pp. 1819-1833, 1997   DOI   ScienceOn
27 R.A. Street, S. Nelson, L. Antonuk, and V. Perez-Mendez, 'Amorphous silicon sensor arrays for radiation imaging,' Proc. Mater. Res., vol. 192, pp. 441-452, 1990   DOI
28 E. Samei, 'Image quality in two phosphor-based flat panel digital radiographic detectors,' Med. Phys., vol. 30, pp. 1747-1757, 2003   DOI   ScienceOn
29 J.H. Siewerdsen, L.E. Antonuk, Y. El-Mohri, J. Yorkston, W. Huang, J.M. Boudry, and I.A. Cunningham, 'Empirical and theoretical investigation of the noise performance of indirect detection, active matrix flat-panel imagers (AMFPIs) for diagnostic radiology,' Med. Phys., vol. 24, pp. 71-89, 1997   DOI   ScienceOn
30 H.K. Kim, 'Analytic model for incomplete signal generation in semiconductor detectors,' Appl. Phys. Lett., vol. 88, p. 132112, 2006   DOI   ScienceOn
31 J.H. Siewerdsen and D.A. Jaffray, 'A ghost story: Spatiotemporal response characteristics of an indirect-detection flat-field imager,' Med. Phys., vol. 26, pp. 1624-1641, 1999   DOI   ScienceOn
32 J.-M. Kim, H.K. Kim, M.H. Cheong, M.K. Cho, C.-S. Shon, and C.H. Lim, 'Investigation of scintillation screens for x-ray imaging,' Key Eng. Mater., vols. 321-323, pp. 1056-1059, 2006
33 M. Zahangir Kabir, M. Yunus, S.O. Kasap, O. Tousignant, H. Mani, and P. Gauthier, 'Sensitivity of stabilized a-Se based x-ray photoconductors,' Current Appl. Phys., vol. 6, pp. 393-398, 2006   DOI   ScienceOn
34 J. Yao and I.A. Cunningham, 'Parallel cascades: New ways to describe noise transfer in medical imaging systems,' Med. Phys., vol. 28, pp. 2020-2038, 2001   DOI   ScienceOn
35 H.K. Kim, 'Cone-beam microtomography and its application,' J. Kor. Soc. Prec. Eng., vol. 22, no. 3, pp. 7-14, 2005
36 G. Cho, H.K. Kim, Y.H. Chung, D.K. Kim, H.K. Lee, T.S. Suh, and K.S. Joo, 'Monte Carlo analyses of x-ray absorption, noise, and detective quantum efficiency considering therapeutic x-ray spectrum in portal imaging detector,' IEEE Trans. Nucl. Sci., vol. 18, pp. 1423-1427, 2001
37 J. Bogaerts and B. Dierickx, 'Total dose effects on CMOS active pixel sensors,' Proc. SPIE, vol. 3965, pp. 157-167, 2000   DOI
38 J.T. Dobbins III, 'Effects of undersampling on the proper interpretation of modulation transfer function, noise power spectra, and noise equivalent quanta of digital imaging systems,' Med. Phys., vol. 22, pp. 171-181, 1995   DOI   ScienceOn
39 M.K. Cho, H.K. Kim, T. Graeve, and J.-M. Kim, 'Characterization of CMOS pixel detectors for digital x-ray imaging,' Key Eng. Mater., vols. 321-323, pp. 1052-1055, 2006
40 H.J. Barnaby, 'Total-ionizing-dose effects in modern CMOS technologies,' IEEE Trans. Nucl. Sci., vol. 53, pp. 3103-3121, 2006   DOI   ScienceOn
41 B.A. Arnold and B.E. Bjarngard, 'The effect of phosphor K x-rays on the MTF of rare-earth screens,' Med. Phys., vol. 6, pp. 500-503, 1979   DOI   ScienceOn
42 J.T. Dobbins III, E. Samei, N.T. Ranger, and Y. Chen, 'Intercomparison of methods for image quality characterization. II. Noise power spectrum,' Med. Phys., vol. 33, pp. 1466-1475, 2006   DOI   ScienceOn
43 A.W. Rau, L. Bakueva, and J.A. Rowlands, 'The x-ray time of flight method for investigation of ghosting in amorphous selenium-based flat panel medical x-ray imagers,' Med. Phys., vol. 32, pp. 3160-3177, 2005   DOI   ScienceOn
44 H.K. Kim, S.C. Lee, M.H. Cho, S.Y. Lee, and G. Cho, 'Use of a flat-panel detector for microtomography: A feasibilitystudy for small-animal imaging,' IEEE Trans. Nucl. Sci., vol. 52, no. 1, pp. 193-198, 2005   DOI   ScienceOn
45 E. Samei and M.J. Flynn, 'An experimental comparison of detector performance for direct and indirect digital radiography systems,' Med. Phys., vol. 30, pp. 608-622, 2003   DOI
46 R. Ning, B. Chen, R. Yu, D. Conover, X. Tang, and Y. Ning, 'Flat panel detector-based cone-beam volume CT angiography imaging: System evaluation,' IEEE Trans. Med. Imag., vol. 19, pp. 949-963, 2000   DOI   ScienceOn