A Study of Testing Method for Diagnostic Ultrasonic Array Probe through Pattern Analysis of Acoustic-Fields with Probe Channel Division |
Yoo, B.C.
(Dept. of Biomedical Engineering, College of Bioscience Engineering, Inje University)
Choi, H.H. (Dept. of Biomedical Engineering, College of Bioscience Engineering, Inje University) Noh, S.C. (Dept. of Biomedical Engineering, College of Bioscience Engineering, Inje University) Min, H.K. (Dept. of Biomedical Engineering, College of Bioscience Engineering, Inje University) Kwon, J.W. (Dept. of Computer Engineering, College of IT, Dongmyong University) |
1 | K. R. Erikson, F. J. Fry, and J. P. Jones, 'Ultrasound in medicine - A review,' IEEE Trans. Sonics Ultrason., vol. SU-21, pp. 144-170, 1974 |
2 | Mills, D. M, 'Medical Imaging with capacitive micromachined ultrasound trasnducer(cMUT) array,' in Proc. IEEE Ultrason. Symp., pp. 384-390, 2004 |
3 | F. V. Hunt, Electroacoustics: The Analysis of Transduction, and Its Historical Backgroun., New York, USA: Acoustical Society of America, 1982 |
4 | W. A Smith, 'The role of piezocornposites in ultrasonic transducers,' in Proc. IEEE Ultrason. Symp., 1989, pp. 755 - 766 |
5 | S. Holm, 'Bessel and Conical Beams and Approximation with Annular Arrys,' IEEE Trans. Ultrason. Ferroelect., and Freq. Contr., vol. 45, no.3, pp. 712-718,1998 DOI ScienceOn |
6 | L. Azar and S. C. Whoo, 'Experimental Characterization of Ultrasonic Phased Arrays for the Nondestructive Evaluation of Concrete Structures,' Materials Evaluations., vol. 75, no. 2, pp. 134-140,1999 |
7 | J. A. Jensen, A new calculation procedure for spatial impulse responses in ultrasound: In press, JASA, 1999 |
8 | S. W. Smith, H.G. Pavy, Jr., and O. T. von Ramm, 'High-speed ultrasound volumetric imaging system - Part I: Transducer design and beam steering,' IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. UFFC-38, pp. 100-108, Mar. 1991 |
9 | S. D. Sagong, M. J. Jo, B. Y. Choi, 'Design of the calibration system for determining the sensitivity of ultrasonic transducer,' Journal of Control, Automation and Systems Engineering, vol. 5, no. 2, pp. 200-207, 1999 과학기술학회마을 |
10 | Korean Standards Association, KS P IEC 61102, Measurement and characterization of ultrasonic fields using hydrophones in the frequency range 0.5MHz to 15MHz, 2004 |
11 | James A. Zagzebski, Essential of Ultrasound Physics, 2nd ed. Mosby-Year Book, 1996 |
12 | J. Meunier, 'Ultrasonic texture motion analysis: theory and simulation,' IEEE Transactions on medical imaging, vol. 14, pp. 293-300,1995 DOI ScienceOn |
13 | Korean Standards Association, KS P 1216, MANUAL SCANNING B-MODE ULTRASONIC DIAGNOSTIC EQUIPMENT, 2001 |
14 | G. R. Harris, 'Hydrophone measurement in diagnostic ultrasonic fields,' IEEE Trans. Ultrason., Ferroelec., Freq. Contr., UFFC-35, pp. 87, 1988 |
15 | H. H. Choi, Medical Ultrasound: Intervision, 2002 |
16 | A. Macovski, 'Ultrasonic Imaging Using Arrays', in Proc. IEEE, vol. 67, no. 4, pp. 484-495, 1979 DOI ScienceOn |
17 | R. Krimholtz, J.D. Fraser and G.S. Kino, New Equivalent Circuits for Elementary Piezoelectric Transducer, Electronics Letters6, 1970, pp. 398-399 DOI ScienceOn |
18 | B. Schneider and K. K. Shung, 'Quantitative analysis of pulsed ultrasonic beam patterns using a Schieren System,' IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 43, pp. 1181-1186, 1996 DOI ScienceOn |
19 | http://www.bipm.org/enus/2_Committees/ |
20 | J. W. Goodman,Introduction to Fourier Optics, New York, USA : McGraw Hill Inc., 1996 |
21 | O. T. von Ramm, S. W. Smith, and H. G. Pavy, Jr., 'Highspeed ultrasound volumetric imaging system - Part II: Parallel processing and image display,' IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. UFFC-38, pp. 109 - 115, Mar. 1991 |
22 | D. R. Bacon, 'Ultrasonic Schlieren using a pulsed gaslaser,' IEEE trans. Sonics Ultrason., vol. 43, pp. 282-285,1971 |