Browse > Article
http://dx.doi.org/10.9718/JBER.2006.27.4.154

A Low-noise Multichannel Magnetocardiogram System for the Diagnosis of Heart Electric Activity  

Lee, Yong-Ho (Bio-signal Research Center, Korea Research Institute of Standards and Science)
Kim, Ki-Woong (Bio-signal Research Center, Korea Research Institute of Standards and Science)
Kim, Jin-Mok (Bio-signal Research Center, Korea Research Institute of Standards and Science)
Kwon, Hyuk-Chan (Bio-signal Research Center, Korea Research Institute of Standards and Science)
Yu, Kwon-Kyu (Bio-signal Research Center, Korea Research Institute of Standards and Science)
Kim, In-Seon (Bio-signal Research Center, Korea Research Institute of Standards and Science)
Park, Yong-Ki (Bio-signal Research Center, Korea Research Institute of Standards and Science)
Publication Information
Journal of Biomedical Engineering Research / v.27, no.4, 2006 , pp. 154-163 More about this Journal
Abstract
A 64-channel magnetocardiogram (MCG) system using low-noise superconducting quantum interference device (SQUID) planar gradiometers was developed for the measurements of cardiac magnetic fields generated by the heart electric activity. Owing to high flux-to-voltage transfers of double relaxation oscillation SQUID (DROS) sensors, the flux-locked loop electronics for SQUID operation could be made simpler than that of conventional DC SQUIDs, and the SQUID control was done automatically through a fiber-optic cable. The pickup coils are first-order planar gradiometers with a baseline of 4 em. The insert has 64 planar gradiometers as the sensing channels and were arranged to measure MCG field components tangential to the chest surface. When the 64-channel insert was in operation everyday, the average boil-off rate of the dewar was 3.6 Lid. The noise spectrum of the SQUID planar gradiometer system was about 5 fT$_{rms}$/$\checkmark$Hz at 100 Hz, operated inside a moderately shielded room. The MCG measurements were done at a sampling rate of 500 Hz or 1 kHz, and realtime display of MCG traces and heart rate were displayed. After the acquisition, magnetic field mapping and current mapping could be done. From the magnetic and current information, parameters for the diagnosis of myocardial ischemia were evaluated to be compared with other diagnostic methods.
Keywords
SQUID; magnetocardiogram; multichannel system; heart disease;
Citations & Related Records
연도 인용수 순위
  • Reference
1 J. M. Kim, Y. H. Lee, K. Kim, H. Kwon, Y. K. Park, and I. Sasada, 'Compact readout electronics for 62-channels DROS magnetocardiography system,' IEEE Trans. Appl. Supercond., vol. 15, pp.644-647, 2005   DOI   ScienceOn
2 R. Fenici, D. Brisinda, and A. M. Meloni, 'Clinical application of magnetocardiography,' Expert Rev. Mol. Diagn., vol. 5, pp.291-313,2005   DOI   ScienceOn
3 Y. H. Lee, H. C. Kwon, J. M. Kim, Y. K. Park, and J. C. Park, 'Double relaxation oscillation SQUID with reference junction for biomagnetic multi-channel applications,' Appl. Supercond., vol. 5, pp.413-418, 1998   DOI   ScienceOn
4 H. Nowak, Biomagnetism, In: Magnetism in Medicine, W. Andra and H. Nowak Ed., Berlin: Wiley-VCR, pp.85-135, 1998
5 S. Yamada, and I. Yamaguchi, 'Magnetocardiograms in clinical medicine: unique information on cardiac ischemia, arrhythmias, and fetal diagnosis,' Internal Medicine, vol. 44, pp: 1-19,2005   DOI
6 Y. H. Lee,J. M. Kim, K. Ki, H. Kwon, K. K. Yu, I. S. Kim, and Y. K. park, '64-channel magnetocardiogram system based on double relaxation oscillation SQUID planar gradiometers,' Supercond. Sci. Technol., vol. 19, pp.S284-288, 2006   DOI   ScienceOn
7 K. Kim, Y. H. Lee, H. Kwon, J. M. Kim, I. S. Kim, and Y. K. Park, 'Optimal sensor distribution for measuring the tangential field components in MCG,' in Proc. 14th Int. Conf Biomagnetism Boston, 2004, pp.359-360
8 J. Nurnminen, S. Ahlfors, R. Ilmoniemi, J. Montonen and J. Nenonen, 'Transformation of multichannel magnetocardiographic signals to standard grid form,' IEEE Trans. Biomed. Eng., vol. 42, pp.72-78, 1995   DOI   ScienceOn
9 V. Pizzella, S. D. Penna, C. Del Gratta, and G. L. Romani, 'SQUID systems for biomagnetic imaging,' Supercond. Sci. Technol., vol. 12, pp.R79-R114, 2001
10 G. Stroink, W. Moshage, and S. Achenbach, Cardiomagnetism, In: Magnetism in Medicine, W. Andrii and H. Nowak Ed., Berlin: Wiley-VCH, pp.136-l89, 1998
11 J. W. Park, and F. Jung, 'Qualitative and Quantitative Description of Myocardial Ischemia by means of magnetocardiography,' Biomed. Technik., vol. 49, pp.267-273, 2004
12 D. J. Adelerhof, H. Nijstad, J. Flokstra, and H. Rogalla, '(Double) relaxation oscillation SQUIDs with high flux-tovoltage transfer: Simulations and experiments,' J. Appl. Phys., vol. 76, pp.3875-3886, 1994   DOI   ScienceOn