Computer Aided Diagnosis System for Evaluation of Mechanical Artificial Valve  

이혁수 (안동대학교 정보전자공학교육과)
Publication Information
Journal of Biomedical Engineering Research / v.25, no.5, 2004 , pp. 421-430 More about this Journal
Abstract
Clinically, it is almost impossible for a physician to distinguish subtle changes of frequency spectrum by using a stethoscope alone especially in the early stage of thrombus formation. Considering that reliability of mechanical valve is paramount because the failure might end up with patient death, early detection of valve thrombus using noninvasive technique is important. Thus the study was designed to provide a tool for early noninvasive detection of valve thrombus by observing shift of frequency spectrum of acoustic signals with computer aid diagnosis system. A thrombus model was constructed on commercialized mechanical valves using polyurethane or silicon. Polyurethane coating was made on the valve surface, and silicon coating on the sewing ring of the valve. To simulate pannus formation, which is fibrous tissue overgrowth obstructing the valve orifice, the degree of silicone coating on the sewing ring varied from 20%, 40%, 60% of orifice obstruction. In experiment system, acoustic signals from the valve were measured using microphone and amplifier. The microphone was attached to a coupler to remove environmental noise. Acoustic signals were sampled by an AID converter, frequency spectrum was obtained by the algorithm of spectral analysis. To quantitatively distinguish the frequency peak of the normal valve from that of the thrombosed valves, analysis using a neural network was employed. A return map was applied to evaluate continuous monitoring of valve motion cycle. The in-vivo data also obtained from animals with mechanical valves in circulatory devices as well as patients with mechanical valve replacement for 1 year or longer before. Each spectrum wave showed a primary and secondary peak. The secondary peak showed changes according to the thrombus model. In the mock as well as the animal study, both spectral analysis and 3-layer neural network could differentiate the normal valves from thrombosed valves. In the human study, one of 10 patients showed shift of frequency spectrum, however the presence of valve thrombus was yet to be determined. Conclusively, acoustic signal measurement can be of suggestive as a noninvasive diagnostic tool in early detection of mechanical valve thrombosis.
Keywords
Mechanical valve; Noninvasive diagnosis; Computer aided diagnosis; Acoustic signal; Frequency spectrum;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Linear and Nonlinear ARMAN Model Parameter Estimation Using an Artificial Neural Network /
[ K. H. Chon;R. J. Choen ] / IEEE Trans. Biomed. Eng   DOI   ScienceOn
2 /
[ 민병구;이상훈( 외). ] / 인공장기
3 Thromboembolic complications of current cardiac valvular prosthesis /
[ Edmunds L. Henry Jr. ] / Ann. Thorac. Surg   DOI   ScienceOn
4 Thrombosis of prosthetic heart valves: diagnosis and management /
[ Horstkotte D;Piper C;Schulte HD. ] / Z Kardiol   DOI   ScienceOn
5 Guidelines for Reporting Morbidity and Mortality after Cardiac Valvular Operations /
[ Edmunds, L. Henry Jr.;Clark Richard E.;Cohn, Lawrence H.;Grunkemeier, Gary L.;Miller, D. Craig;Weisel, Richard D. ] / Ann. Thorac. Surg   DOI
6 Obstruction of mechanical valve prosthese:clinical diagnosis and surgical or nonsurgical treatment /
[ Aoyagi S;Fukunaga S;Suzuki S;Nishi Y;Oryoji A;Kosuga K. ] / Surg Today   DOI   ScienceOn
7 Thrombolytic therapy of left-sided prosthetic valve thrombosis /
[ Koller PT;Arom KV. ] / Chest   DOI   ScienceOn
8 Evaluation of FFT-based and modern parametric methods for the spectral analysis of bioprosthetic valve sounds /
[ L. G. Durand;J. D. Guise;G. Cloutier;R. Guardo;M. Brais ] / IEEE Trans. Biomedical Eng   DOI
9 Detection of Aortic Porcine Valve Dysfunction by maximum Entropy Spectral Analysis /
[ R. A. Foale;T. H. Joo (et al.) ] / Circulation   DOI
10 Noninvasive Diagnosis of Mechanical Failure of the Implanted Total Artificial Heart Using Neural Network Analysis of Acoustic Signals /
[ H. C. Kim;S. K. Park (et al.) ] / ASAIO J   DOI
11 Diagnosis of prosthetic heart valve thrombosis /
[ Habib G;Cornen A;Mesana T;Monties JR;Djiane P;Luccioni R. ] / The respective values of transthoracic and transesophageal Doppler echocardiography. Eur Heart J.
12 Obstruction of mechanical heart valve prosthesis: clinical aspect and surgical management /
[ Derivi E;Sareli P;Wisenbaugh T (et al.) ] / J. Am. Coll. Cardiol.
13 Prosthetic valve obstruction:thrombolysis versus operation /
[ Vitale N;Rensulli A;Cerasuolo F;Caruso A;Festa M;de Luca L;Cotrufo M. ] / Ann. Thorac. Surg.   DOI   ScienceOn
14 Prosthetic valve thrombosis /
[ Horstkotte D;Burckhardt D ] / J. Heart Valve Dis
15 In Vivo Testing of a Completely Implantable Total Artificial heart System /
[ A. J. Snyder;G. Rosenberg (et al.) ] / Am. Soc. Artif. Intern. Organs
16 소아환자에서 St. Jude Medical 인공판막의 혈전현상 /
[ 김삼현;신제균;박인숙;홍창의 ] / 대한흉부외과학회지
17 Non-invasive Acoustical Evaluation of the Utah Electrohydraulic Total Artificial Heart /
[ H. L. Hinrichs;J. R. Fratto (et al.) ] / ASAIO J
18 /
[ 오창석 ] / 뉴로컴퓨터
19 Classification of prosthetic heart valve sounds: A parametric approach /
[ J. V. Candy;H. E. Jones ] / J. Acoust. Soc. Am   DOI   ScienceOn
20 Spectral Composition of Heart Sunds Before and After Mechanical Heart Valve Implantation Using a Madified Forward-Backward Prony's Method /
[ Herkole P. Sava;J. T. Edward McDonnell ] / IEEE Trans. Biomedical Eng   DOI   ScienceOn
21 Comparison of Pattern Recognition Method for Computer Assisted Classification of Spectra of Heart Sounds in Patient with a Porcine Bioprosthetic Valve Implanted in the Mitral Position /
[ L. G Durand;M. Blanchard (et al.) ] / IEEE Trans. Biomed. Eng   DOI   ScienceOn
22 Performance Evaluation of Implantable Artificial Organs by Sound Spectrum Analysis /
[ S. H. Lee;B. G. Min ] / ASAIO J   DOI
23 In-Vitro Thrombosis Detection of Mechanical valve Using Artificial Neural Network /
[ H.S. Lee;S.H. Lee ] / J. of KOSOMBE
24 Real-time sound spectroanalysis for diagnosis of malfunctioning prosthetic valves /
[ Yuzuru;Kagawa ] / J. Thrac. Cardiovasc. Surgery
25 Universal approximation bounds for superpositions of a sigmoidal function /
[ A. R. Barron ] / IEEE Trans. on Information Theory   DOI   ScienceOn