Gas Transfer and Hemolysis Characteristics of a New Type Intravenous Lung Assist Device  

김기범 (전북대학교 공과대학 화학공학부)
권대규 (전북대학교 메카트로닉스연구센터)
정경락 (공학연구원 공업기술연구센터)
이삼철 (한려대학교 물리치료학과)
Publication Information
Journal of Biomedical Engineering Research / v.24, no.2, 2003 , pp. 121-126 More about this Journal
Abstract
The purpose of this work was to assess and quantify whether the beneficial effects in long-term gas exchange at exciting frequency were obtained at different frequencies as well and then to develop a vibrating intravascular lung assist device(VIVLAD), for Patients suffering from acute respiratory distress syndrome(ARDS) or chronic respiratory problems. We investigate the optimal condition of the frequency band excited with new vibrator at state of limit hemolysis when blood hemolysis came to through a membrane vibration action. The experimental design and procedures were given for a device used to assess the effectiveness of membrane vibrations. Quantitative experimental measurements were performed to evaluate the performance of the device . and to identify membrane vibration dependence on blood hemolysis. We developed an analytical solution for the hydrodynamics of flow through a bundle of sinusoidally vibrated hollow fibers that is used to provide some insight into how wall vibrations might enhance the performance of the VIVLAD. In the result, it was measured that the effect of various excited frequencies in gas transfer rate and hemolysis from the maximum gas transfer rate at no vibration when the maximum gas transfer rates showed at module type 6, module type 6 consisted of 675 hollow fiber membranes The maximum oxygen transfer rate was caused by the occurrence of maximum amplitude and transfer of vibration to hollow fiber membranes when it was excited by the frequency band of 7Hz at each blood flow rate. because this frequency became the End mode resonance frequency of the flexible in blood flow. Also, when module type 6 was excited at an excited frequency of 7Hz. blood hemolysis was low. Therefore, we decided that the limit of hemolysis frequency is 7Hz . because maximum amplitude occurred at this frequency.
Keywords
Artificial lung; Pressure drop; Gas transfer; Hollow fiber membranes; Vibration;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 The evaluation of artificial lung using blood substitutes /
[ Lee, S. C.;Kim, K. B.;Hong, S. C.;Kim, M. H.;Jheong, G. R. ] / Journal of Biomedical Engineering Research   과학기술학회마을
2 Clinical trials for lung transplant candidates on the horizon for early next year /
[ Kara Gavin ] / U-M artificial lung showing promise, as need grows
3 The Need for Standardizing the Index of Hemolysis /
[ Naito K;Mizuguchi K;Nose Y ] / Artificial Organs   ScienceOn
4 Develoment of an intravacular lung assist device /
[ Vaslef, Steven N.;Mockros, Lyle F.;Anderson, Robert W. ] / Trans. am. Soc. Artif. Intern. Organs
5 Recent progress in engineering the Pittsburgh intravenous membrane oxygenator /
[ Federspiel, William J.;Hewitt, Todd J.;Hout, Mariah S.;Walters, Frank R. et al. ] / ASAIO J.   ScienceOn
6 Neonatal congenital diaphragmatic hernia and extracorporeal membrane oxygenation /
[ Finder, N. N.;Tierney, A. J.;Hallgren, R.;Hayashi, A.;Peliowski, A.;Etches, P. C. ] / Can Med. Assoc. J.
7 Extracorporeal circulation in neonatal resiratory failure: a prospective randomized study /
[ Bartlett, R. H.;Roloff, D. W.;cornell, R. G.;Andrews, A. F.;Dillon, P. W.;Zwischenberger, A. B. ] / Pediatrics
8 An economic analysis of extracorporeal membrane oxygenation /
[ Pearson, G. D.;Short, B. L. ] / J. Intens. Care. Med.
9 Design and evaluation of a new, low pressure loss, implantable artificial lung /
[ Vaslef, Steven N.;Cook, Keith E.;Leonard, Ronald J.;Mockros, Lyle F.;Anderson, Robert W. ] / ASAIO J.
10 A mathematical model of gas exchange in an intravenous membrane oxygenator /
[ Hewitt, Todd J.;Hattler, Brack. G.;Federspiel, William J. ] / Ann. Biomed. Eng.   ScienceOn
11 Gas flow dynamics in hollow-flber- membranes /
[ Federspiel, William J.;William Jeffrey L.;Hattler, Brack G. ] / AIChE J.
12 Changing criteria for the artificial lung: Historic controls on the technology of ECMO /
[ Campell, Terry G. ] / ASAIO J.
13 Recommended Practice for Assessment of Hemolysis in Continous Flow Blood Pump /
[ Nose Y ] / PA:Americal Society of Testing and Materials
14 Enhancement of O2 and CO2 transfer through microporous hollow fiber by pressure cycling /
[ Nodelman;Vladislav;Baskaran;Harihara;Ultman, James S. ] / Annals of Biomedical Engineering   ScienceOn
15 Development of a low flow resistance intravenous oxygenator /
[ Fedspiel, W. J.;Hout, M. S.;Hewitt, T. J.;Lund, L. W.;Heinrich, S. A.;Litwak, P.;Walters, F. R.;Reeder, G. D.;Borovetz, H. S.;Hattler, B. G. ] / ASAIO J.   ScienceOn
16 Ex-vivotesting of the inravenous membrane oxygenator(IMO) /
[ Federspiel, William J.;Lund, L. W.;Bultman, J. A.;Wanant, S.;Matoney, J.;Golob, J. F.;Frankowski, B. J. Watach, M.;Litwak, P.;Hattler, B. G. ] / ASAIO J.