Abstract
The purpose of this study was to determine how smartphone use posture affects biomechanical variables and muscle activities. Eleven university students(age: $22.2{\pm}2.6$ yrs, height: $176.6{\pm}4.7$ cm, weight: $69.5{\pm}7.5$ kg) who have no musculoskeletal disorder were recruited as the subject according to having experience in using the smartphone for more than one year. Angular velocity, muscle activity, and thumb finger pressure were determined for each trial. For each dependent variable, a one-way analysis of variance (ANOVA) with repeated measures was performed to test if significant difference existed among different three conditions (p<.05). The result showed that rotational angular velocity of the first metacarpal were increased in DESK posture compared with STAND posture during SU phase. The average nEMG values of FDI(First dorsal interosseous) were less in SIT and DESK posture compared with STAND posture during SR phase. These indicated that smartphone postures may effect the thumb ROM(Range of motion) and muscle activity. This has led to suggestions of the need for further kinetic and EMG analyses to evaluate best assess and characterize with smartphone use.
Keywords
Smartphone; Kinematic; Kinetic; Electromyography; Thumb; Stress; Strain;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Aaras, A., Horgen, G., Bjorset, H. H., Ro, O., & Thoresen, M.(1998). Musculoskeletal, visual and psychosocial stress in VDU operators before and after multidisciplinary ergonomic interventions. Applied Ergonomics, 29(5), 335-354.   DOI   ScienceOn
2 Aaras, A., Horgen, G., Bjorset, H. H., Ro, O., & Walsoe, H.(2001). Musculoskeletal, visual and psychosocial stress in VDU operators before and after multidisciplinary ergonomic interventions. A 6 years prospective study-Part II. Applied Ergonomics, 32(6), 559-571.   DOI
3 Abdel-Aziz, Y., & Karara, H. M.(1971). Direct linear transformation from comparator coordinates in object-space coordinates in close range photogrammetry. Proceedings of the ASP Symposium of Close-Range Photogrammetry. Urbana, IL.
4 Amis, A. A.(1987). Variation of finger forces in maximal isometric grasp tests on a range of cylinder diameters. Journal of Biomedical Engineering Research, 9(4), 313-320.   DOI
5 Bae, J. K., & Jeong, H. M.(2008). An empirical study on the determinants factors by including functional attributes of smart phone adoption. The E-Business Studies, 9(4), 337-361.   DOI
6 Cnet News(2010). Teen gets carpal tunnel from texting, wants iPhone. Retrieved March 20, 2010 from http://news.cnet .com/8301-17852_3-10469723-71.html.
7 Cook, C., Burgess-Limerick, R., & Papalia, S.(2004). The effect of wrist rests and forearm support during keyboard and mouse use. International Journal of Industrial Ergonomics, 33(5), 463-472.   DOI   ScienceOn
8 Cram, J. R., & Kasman, G. S.(1998). Introduction to surface electromyography. Alexandria: Aspen Publications.
9 Fontana, L., Neel, S., Claise, J. M., Ughetto, S., & Catilina, P.(2007). Osteoarthritis of the thumb carpometacarpal joint in women and occupational risk factors: a case-control study. Journal of Hand Surgery, 32(4), 459-465.   DOI   ScienceOn
10 Gustafsson, E., Johnson, P. W., & Hagberg, M.(2008). Thumb postures and physical loads during mobile phone use - a comparison of young adults with and without musculoskeletal symptoms. Journal of Electromyography and Kinesiology, 20(1), 127-135.
11 Hall, C.(1997). External pressure at the hand during object handling and work with tools. International Journal of Industrial Ergonomics, 20(3), 191-206.   DOI
12 Jonsson, P., Johnson, P. W., & Hagberg, M.(2007). Accuracy and feasibility of using an electrogoniometer for measuring simple thumb movements. Ergonomics, 50(5), 647-659.   DOI   ScienceOn
13 Hankookilbo(2011). Dangerously smart? Retrieved February 7, 2011 from http://sports.hankooki.com/lpage/life/ 201102/sp20110207135439109540.htm.
14 Hansson, G. A., Balogh, I., Ohlsson, K., Granqvist, L., Nordander, C., & Arvidsson, I.(2009). Physical workload in various types of work: Part I. Wrist and forearm. International Journal of Industrial Ergonomics, 39(1), 221-233.   DOI
15 Jonsson, P., & Johnson, P. W.(2001). Comparison of measurement accuracy between two types of wrist goniometer systems. Applied Ergonomics, 32(6), 599-607.   DOI
16 Jonsson, P., Johnson, P. W., Hagberg, M., & Forsman, M.(2011). Thumb joint movement and muscular activity during mobile phone texting - A methodological study. Journal of Electromyography and Kinesiology, 21(2), 363-370.   DOI   ScienceOn
17 Mathiassen, S. E., Winkel, J., & Hagg, G. M.(1995). Normalization of surface EMG amplitude from the upper trapezius muscle in ergonomic studies - A review. Journal of Electromyography and Kinesiology, 5(4), 197-226.   DOI   ScienceOn
18 Ming, Z., Pietikainen, S., & Hanninen, O.(2006). Excessive texting in pathophysiology of first carpometacarpal joint arthritis. Pathophysiology, 13(4), 269-270.   DOI   ScienceOn
19 MK Business(2010). In 2011, the smartphone ownership rates in South Korea. Retrieved October 11, 2010 from http:// news.mk.co.kr/v3/view.php?year=2010&no=549160.
20 Moore, J. S.(1997). De Quervain's tenosynovitis. Stenosing tenosynovitis of the first dorsal compartment. Journal of Occupational and Environmental Medicine, 39(10), 990-1002.   DOI
21 Perotto, A., & Delagi, E. F.(1994). Anatomical guide for the electromyographer : the limbs and trunk(3rded.). Springfield, Ill., USA: Charles C. Thomas.
22 Nigg, B. M., & Bobbert, M.(1990). On the potential of various approaches in load analysis to reduce the frequency of sports injuries. Journal of Biomechanics, 23(1), 3-12.   DOI   ScienceOn
23 Park, S. C., Kim, J. H., & Kim C. J.(1995). A study on preferred height and pange of discomfort recognition for designing educational desks and chairs. Journal of the Ergonomics Society of Korea, 14(2), 41-50.
24 Pascarelli, E. F., & Kella, J. J.(1993). Soft-tissue injuries related to use of the computer keyboard: A clinical study of 53 severely injured persons. Journal of Occupational Medicine, 35, 522-532.
25 Shaw, S. J., & Morris, M. A.(1992). The range of motion of the metacarpo-phalangeal joint of the thumb and its relationship to injury. Journal of Hand Surgery: British & European Volume, 17(2), 164-166.   DOI
26 van Oudenaarde, E., Elvers, J. W., Gielen, C. C., Kauer, J. M., Oostendorp, R. A., & van der Straaten, J. H.(1995). Differences and similarities in electrical muscle activity for the abductor pollicis longus muscle divisions. Journal of Electromyography and Kinesiology, 5(1), 57-64.   DOI   ScienceOn
27 Wood, G.(1982). Data smoothing and differentiation procedures in biomechanics. In R. L. Terjung (Eds.), Exercise and Sport Sciences Reviews; Vol. 10, 308-362. Lexington, MA: D.C. Health and Company.