Practical Considerations in Preparing an Institutional Procedure of Image Guided Radiation Therapy  

Yi, Byong Yong (Department of Radiation Oncology, University of Maryland School of Medicine)
Publication Information
Progress in Medical Physics / v.24, no.4, 2013 , pp. 205-212 More about this Journal
Abstract
Recent developments of image guided radiation therapy (IGRT), especially the On Board Imaging (OBI) system and the cone beam CT (CBCT), enable the radiation treatment more accurate and reliable. IGRT is widely used in the radiation therapy as a standard of care. Use of IGRT is even expected to increase in the near future. IGRT is only beneficial to patients when it is used with proper considerations of safety and appropriateness of the techniques. Institutional procedure should be developed based on the clinical need and the deep understanding of the system before applying the new technique to the clinic. Comprehensive QA program should be established before to the clinic and imaging dose should be considered when preparing the departmental practice guidelines for IGRT.
Keywords
IGRT; QA; Institutional procedure;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Pouliot J, Bani-Hashemi A, Chen J, et al: Low-dose mega- voltage cone-beam CT for radiation therapy. Int J Radiat Oncol Biol Phys 61(2):552-560 (2005)   DOI   ScienceOn
2 Yin FF, Wong J, Balter J, et al: The Role of In-room kV x-ray Imaging for Patient Setup and Target Localization: Report of AAPM Task Group 104, in AAPM Report, American Association of Physicists in Medicine, College Park, MD (2009).
3 Guckenberger M, Meyer J, Wilbet J, et al: Cone-beam CT based image-guidance for extracranial stereotactic radiotherapy of intrapulmonary tumors. Acta Oncologica 45(7):897-906 (2009)
4 Li H, Zhu XR, Zhang L, et al: Comparison of 2D radiographic images and 3D cone beam computed tomography for positioning head-and-neck radiaotherapy patients. Int J Radiat Oncol Biol Phys 71(3):916-925 (2008)   DOI   ScienceOn
5 Boda-Heggemann J, Lohr F, Wenz F, Flentje M, Guckenberger M: kV Cone-Beam CT-based IGRT: A clinical Review. Strahlentherapie und Onkologie 187(5):284-291 (2011)
6 Morr J, DiPetrillo T, Tsai JS, Engler M, Wazer DE: Implementation and utility of a daily ultrasound-based localization system with intensity-modulated radiotherapy for prostate cancer. Int J Radiat Oncol Biol Phys 53(5):1124-1129 (2002)   DOI   ScienceOn
7 Chandra A, Dong L, Huang E, et al: Experience of ultrasound-based daily prostate localization. Int J Radiat Oncol Biol Phys 56(2):436-447 (2003)   DOI   ScienceOn
8 Ding GX, Coffey CW: Radiation dose from kilovoltage cone beam computed tomography in an image-guided radiotherapy procedure. Int J Radiat Oncol Biol Phys 73(1):610-617 (2009)   DOI   ScienceOn
9 Ding GX, Coffey CW: Radiation dose from kilovoltage cone beam computed tomography in an image-guided radiotherapy procedure. Int J Radiat Oncol Biol Phys 73(1):610-617 (2009)   DOI   ScienceOn
10 Ding GX, Coffey CW: Radiation dose from kilovoltage cone beam computed tomography in an image-guided radiotherapy procedure. Int J Radiat Oncol Biol Phys 73(1):610-617 (2009)   DOI   ScienceOn
11 Lee H, Xing L, Lee R, Fahimianb BP: Scatter correction in cone-beam CT via a half beam blocker technique allowing simultaneous acquisition of scatter and image information. Med Phys 39(5):2386-2395 (2012)   DOI   ScienceOn
12 Bissonnette JP, Balter PA, Dong L, et al: Quality assurance for image-guided radiation therapy utilizing CT-based technologies: A report of the AAPM TG-179. Med Phys 39(4):1946-1963 (2012)   DOI   ScienceOn
13 Benedict SH, Yenice KM, Followill D, et al: Stereotactic body radiation therapy: The report of AAPM Task Group 101. Med Phys 37(8):4078-4101 (2010)   DOI   ScienceOn
14 Vergalasova I, Maurer J, Yin FF: Potential underestimation of the internal target volume (ITV) from free-breathing CBCT. Med Phys 38(8):4689-4699 (2011)   DOI   ScienceOn
15 Wen N, Guan H, Hammond R, et al: Dose delivered from Varian's CBCT to patients receiving IMRT for prostate cancer. Phys Med Biol 52(8):2267-2276 (2007)   DOI   ScienceOn
16 Langen KM, Pouliot J, Anezinos C, et al: Evaluation of ultrasound-based prostate localization for image-guided radiotherapy. Int J Radiat Oncol Biol Phys 57(3):635-644 (2003)   DOI   ScienceOn
17 Park YK, Son T, Kim H, et al: Development of real-time motion verification system using in-room optical images for respiratory-gated radiotherapy. JACMP 14(5):25-42 (2013)
18 Greco C, Ling CC: Broadening the scope of Image-Guided Radiotherapy (IGRT). Acta Oncologica 47(7):1193-1120 (2008)   DOI   ScienceOn
19 Lamba M, Breneman JC, Warnick RE: Evaluation of image-guided positioning for frameless intracranial radiosurgery. Int J Radiat Oncol Biol Phys 74(3):913-919 (2009)   DOI   ScienceOn
20 Lerma F, Liu B, Yi B, Amin P, Yu C: Role of image-guided patient repositioning and online planning in localized prostate cancer IMRT. Radiotherapy and Oncology 93(1):18-24 (2009)   DOI   ScienceOn
21 Yi B, Lerma F, Suntharalingam M: Is weekly megavoltage image verification necessary after daily kv image guidance? Int J Radiat Oncol Biol Phys 72(1):S571-S572 (2008)
22 Yoo S, Kim GY, Hammoud R, et al: A quality assurance program for the on-board imagers. Med Phys 33(11):4431-4447 (2006)   DOI   ScienceOn
23 Klein EE, Hanley J, Bayouth J, et al: Task group 142 report: Quality assurance of medical accelerators. Med Phys 36(9):4197-4212 (2009)   DOI   ScienceOn
24 Varian Customer Technical Bulletin, CTB-PV-457a, May 11, 2006.
25 Muirhead R, McNee SG, Featherstone C, Muscat S: Use of maximum intensity projections (MIPs) for target outlining in 4DCT radiotherapy planning. J Thorac Oncol 3(12):1433-1438 (2008)   DOI   ScienceOn
26 Park KW, Huang L, Gagne H, Papiez L: Do maximum intensity projection images truly capture tumor motion? Int J Radiat Oncol Biol Phys 73(2):618-625 (2009)   DOI   ScienceOn
27 Simpson DR, Lawson JL, Nath SK, et al: A survey of image-guided radiaton therapy use in United States. Cancer 116 (16):3953-3960 (2010)   DOI   ScienceOn
28 Lam KS, Partowmah M, Lam WC: An on-line electronic portal imaging system for external beam radiotherapy. Br J Radiol 59:1007-1013 (1986)   DOI   ScienceOn
29 Adler JR Jr, Murphy MJ, Chang SD, Hancock SL: Image-guided robotic radiosurgery. Neurosurgery 44(6):1299-1306 (1999)
30 Sorcini B, Tilikidis A. Clinical application of image-guided radiotherapy (IGRT) on the Varian OBI platform. Cancer Radiother 10(5):252-257 (2006)   DOI   ScienceOn
31 Mosleh-Shirazi MA, Evans PM, Swindell W, Webb S, Partridge M: A cone-beam megavoltage CT scanner for treatment verification in conformal radiotherapy. Radiother Oncol 48(3):319-328 (1998)   DOI   ScienceOn
32 Ding GX, Coffey CW: Radiation dose from kilovoltage cone beam computed tomography in an image-guided radiotherapy procedure. Int J Radiat Oncol Biol Phys 73(1):610-617 (2009)   DOI   ScienceOn
33 Underberg RWM, Lagerwaald FJ, Slotman BJ, Cuijpers JP, Senan S: Use of maximum intensity projections (MIP) for target volume generation in 4DCT scans for lung cancer. Int J Radiat Oncol Biol Phys 63(1):253-260 (2005)   DOI   ScienceOn