1 |
Pouliot J, Bani-Hashemi A, Chen J, et al: Low-dose mega- voltage cone-beam CT for radiation therapy. Int J Radiat Oncol Biol Phys 61(2):552-560 (2005)
DOI
ScienceOn
|
2 |
Yin FF, Wong J, Balter J, et al: The Role of In-room kV x-ray Imaging for Patient Setup and Target Localization: Report of AAPM Task Group 104, in AAPM Report, American Association of Physicists in Medicine, College Park, MD (2009).
|
3 |
Guckenberger M, Meyer J, Wilbet J, et al: Cone-beam CT based image-guidance for extracranial stereotactic radiotherapy of intrapulmonary tumors. Acta Oncologica 45(7):897-906 (2009)
|
4 |
Li H, Zhu XR, Zhang L, et al: Comparison of 2D radiographic images and 3D cone beam computed tomography for positioning head-and-neck radiaotherapy patients. Int J Radiat Oncol Biol Phys 71(3):916-925 (2008)
DOI
ScienceOn
|
5 |
Boda-Heggemann J, Lohr F, Wenz F, Flentje M, Guckenberger M: kV Cone-Beam CT-based IGRT: A clinical Review. Strahlentherapie und Onkologie 187(5):284-291 (2011)
|
6 |
Morr J, DiPetrillo T, Tsai JS, Engler M, Wazer DE: Implementation and utility of a daily ultrasound-based localization system with intensity-modulated radiotherapy for prostate cancer. Int J Radiat Oncol Biol Phys 53(5):1124-1129 (2002)
DOI
ScienceOn
|
7 |
Chandra A, Dong L, Huang E, et al: Experience of ultrasound-based daily prostate localization. Int J Radiat Oncol Biol Phys 56(2):436-447 (2003)
DOI
ScienceOn
|
8 |
Ding GX, Coffey CW: Radiation dose from kilovoltage cone beam computed tomography in an image-guided radiotherapy procedure. Int J Radiat Oncol Biol Phys 73(1):610-617 (2009)
DOI
ScienceOn
|
9 |
Ding GX, Coffey CW: Radiation dose from kilovoltage cone beam computed tomography in an image-guided radiotherapy procedure. Int J Radiat Oncol Biol Phys 73(1):610-617 (2009)
DOI
ScienceOn
|
10 |
Ding GX, Coffey CW: Radiation dose from kilovoltage cone beam computed tomography in an image-guided radiotherapy procedure. Int J Radiat Oncol Biol Phys 73(1):610-617 (2009)
DOI
ScienceOn
|
11 |
Lee H, Xing L, Lee R, Fahimianb BP: Scatter correction in cone-beam CT via a half beam blocker technique allowing simultaneous acquisition of scatter and image information. Med Phys 39(5):2386-2395 (2012)
DOI
ScienceOn
|
12 |
Bissonnette JP, Balter PA, Dong L, et al: Quality assurance for image-guided radiation therapy utilizing CT-based technologies: A report of the AAPM TG-179. Med Phys 39(4):1946-1963 (2012)
DOI
ScienceOn
|
13 |
Benedict SH, Yenice KM, Followill D, et al: Stereotactic body radiation therapy: The report of AAPM Task Group 101. Med Phys 37(8):4078-4101 (2010)
DOI
ScienceOn
|
14 |
Vergalasova I, Maurer J, Yin FF: Potential underestimation of the internal target volume (ITV) from free-breathing CBCT. Med Phys 38(8):4689-4699 (2011)
DOI
ScienceOn
|
15 |
Wen N, Guan H, Hammond R, et al: Dose delivered from Varian's CBCT to patients receiving IMRT for prostate cancer. Phys Med Biol 52(8):2267-2276 (2007)
DOI
ScienceOn
|
16 |
Langen KM, Pouliot J, Anezinos C, et al: Evaluation of ultrasound-based prostate localization for image-guided radiotherapy. Int J Radiat Oncol Biol Phys 57(3):635-644 (2003)
DOI
ScienceOn
|
17 |
Park YK, Son T, Kim H, et al: Development of real-time motion verification system using in-room optical images for respiratory-gated radiotherapy. JACMP 14(5):25-42 (2013)
|
18 |
Greco C, Ling CC: Broadening the scope of Image-Guided Radiotherapy (IGRT). Acta Oncologica 47(7):1193-1120 (2008)
DOI
ScienceOn
|
19 |
Lamba M, Breneman JC, Warnick RE: Evaluation of image-guided positioning for frameless intracranial radiosurgery. Int J Radiat Oncol Biol Phys 74(3):913-919 (2009)
DOI
ScienceOn
|
20 |
Lerma F, Liu B, Yi B, Amin P, Yu C: Role of image-guided patient repositioning and online planning in localized prostate cancer IMRT. Radiotherapy and Oncology 93(1):18-24 (2009)
DOI
ScienceOn
|
21 |
Yi B, Lerma F, Suntharalingam M: Is weekly megavoltage image verification necessary after daily kv image guidance? Int J Radiat Oncol Biol Phys 72(1):S571-S572 (2008)
|
22 |
Yoo S, Kim GY, Hammoud R, et al: A quality assurance program for the on-board imagers. Med Phys 33(11):4431-4447 (2006)
DOI
ScienceOn
|
23 |
Klein EE, Hanley J, Bayouth J, et al: Task group 142 report: Quality assurance of medical accelerators. Med Phys 36(9):4197-4212 (2009)
DOI
ScienceOn
|
24 |
Varian Customer Technical Bulletin, CTB-PV-457a, May 11, 2006.
|
25 |
Muirhead R, McNee SG, Featherstone C, Muscat S: Use of maximum intensity projections (MIPs) for target outlining in 4DCT radiotherapy planning. J Thorac Oncol 3(12):1433-1438 (2008)
DOI
ScienceOn
|
26 |
Park KW, Huang L, Gagne H, Papiez L: Do maximum intensity projection images truly capture tumor motion? Int J Radiat Oncol Biol Phys 73(2):618-625 (2009)
DOI
ScienceOn
|
27 |
Simpson DR, Lawson JL, Nath SK, et al: A survey of image-guided radiaton therapy use in United States. Cancer 116 (16):3953-3960 (2010)
DOI
ScienceOn
|
28 |
Lam KS, Partowmah M, Lam WC: An on-line electronic portal imaging system for external beam radiotherapy. Br J Radiol 59:1007-1013 (1986)
DOI
ScienceOn
|
29 |
Adler JR Jr, Murphy MJ, Chang SD, Hancock SL: Image-guided robotic radiosurgery. Neurosurgery 44(6):1299-1306 (1999)
|
30 |
Sorcini B, Tilikidis A. Clinical application of image-guided radiotherapy (IGRT) on the Varian OBI platform. Cancer Radiother 10(5):252-257 (2006)
DOI
ScienceOn
|
31 |
Mosleh-Shirazi MA, Evans PM, Swindell W, Webb S, Partridge M: A cone-beam megavoltage CT scanner for treatment verification in conformal radiotherapy. Radiother Oncol 48(3):319-328 (1998)
DOI
ScienceOn
|
32 |
Ding GX, Coffey CW: Radiation dose from kilovoltage cone beam computed tomography in an image-guided radiotherapy procedure. Int J Radiat Oncol Biol Phys 73(1):610-617 (2009)
DOI
ScienceOn
|
33 |
Underberg RWM, Lagerwaald FJ, Slotman BJ, Cuijpers JP, Senan S: Use of maximum intensity projections (MIP) for target volume generation in 4DCT scans for lung cancer. Int J Radiat Oncol Biol Phys 63(1):253-260 (2005)
DOI
ScienceOn
|