Browse > Article
http://dx.doi.org/10.1016/j.net.2019.07.005

The design of a scintillation system based on SiPMs integrated with gain correction functionality  

Lin, Zhenhua (AXINT SAS)
Hautefeuille, Benoit (AXINT SAS)
Jung, Sung-Hee (Korea Atomic Energy Research Institute (KAERI))
Moon, Jinho (Korea Atomic Energy Research Institute (KAERI))
Park, Jang-Guen (Korea Atomic Energy Research Institute (KAERI))
Publication Information
Nuclear Engineering and Technology / v.52, no.1, 2020 , pp. 164-169 More about this Journal
Abstract
Use of SiPM has been considered as an alternative to PMT, because of its compact size, low-operating voltage, non-sensitive to electromagnetic, low costs and so on. The main limitation for the use of SiPM is due to its small sensitive area compared to PMT that limits the light collection, and therefore the sensor energy resolution. In this article we studied the effect of increasing the number of SiPM by connecting them in parallel to increase the active detection area. This allowed us to compare the different energy resolution measurements. 137Cs has been selected as reference to study the energy resolution for 662 keV gamma-rays. Another investigation was to compare the minimum detectable gamma energy under various SiPM configurations. It has been found that the use of 4 SiPM arrays can greatly improve the energy resolution up to 4% than only one SiPM array, meanwhile use of more than 2 SiPM arrays does not increase the energy resolution significantly. Thus we can conclude that for a large area of cylindrical scintillator (3 × 3 inches), the use of SiPMs are limited to a certain number or certai active area depending on the commercial SiPMs, and its cost should be less than traditional PMT for the cost-effective and compact size considerations. It is well known that the gain of SiPM varies with temperature. In this article, we also calibrated gain to guarantee the same position of photoelectric peak in response of different temperatures.
Keywords
SiPM configuration; Energy resolution; Minimum detectable gamma energy;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Correction of SiPM Temperature Dependencies, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, vol 610, 2009, pp. 114-117.
2 Z. Lin, O. Tillement, M.-G. Blanchin, V. Jindal, A. Vinsot, R.-V.-H. Dagnelie, V. Blin, Y. Lettry, B. Hautefeuille, The design and fabrication of beta sensor system for in situ diffusion tests in mudstone in France, Appl. Radiat. Isot. 125 (2017) 134-138.   DOI
3 A. Poitrasson-Riviere, M.C. Hamel, J.K. Polack, M. Flaska, S.D. Clarke, S.A. Pozzi, Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip. 760 (2014) 40.   DOI
4 S. Akkoyun, A. Algora, B. Alikhani, F. Ameil, G. de Angelis, L. Arnold, et al., Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip. 668 (2012) 26.   DOI
5 D.P. McElroy, L.R. MacDonald, F.J. Beekman, B.E. Patt, J.S. Iwanczyk, B.M.W. Tsui, et al., IEEE Trans. Nucl. Sci. 49 (2002) 2139.   DOI
6 R. Hofstadter, Phys. Rev. 72 (1947) 1120.   DOI
7 H. Iams, B. Salzberg, The secondary emission phototube, Proc. IEEE 23 (1935) 55-64.
8 D. Renker, Geiger-mode avalanche photodiodes, history, properties and problems, Nucl. Instrum. Methods A567 (2006) 48-56.   DOI
9 Scintillation detectors constructed with an optimized 2x2 silicon photomultiplier array Felix Liang, Member, IEEE, Hartmut Brands, Member, IEEE, Les Hoy, Member, IEEE, Jeff Preston, Member, IEEE, and Jason Smith, Member, IEEE
10 Paolo W. Cattaneo, Matteo De Gerone, Flavio gatti, member, IEEE, miki nishimura, wataru ootani, massimo rossella, and yusuke uchiyama, development of high precision timing counter based on plastic scintillator with SiPM readout, IEEE Trans. Nucl. Sci. 61 (5) (2014) 2657-2666.   DOI
11 Characterization of SiPM, Temperature Dependencies, Marco Ramilli, Nuclear Science Symposium Conference Record, IEEE, 2008. NSS '08.
12 Status of timing with plastic scintillator detectors, M. MOSZYNSKI, B. BENGTSON, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, vol 158, 1979, pp. 1-31.
13 Datasheet AD7814, 10-Bit Digital Temperature Sensor in 6-Lead SOT-23. http://www.analog.com/media/en/technical-documentation/data-sheets/AD7814.pdf.
14 Laraweb. http://www.nucleide.org/Laraweb/index.php.
15 ArrayC PCB Arrays of SiPM User MANUAL, http://www.sensl.com/downloads/ds/UM-ArraySMT.pdf
16 Arthur H. Compton, A quantum theory of the scattering of X-rays by light elements, Phys. Rev. 21 (5) (May, 1923).
17 B.D. Compton, B.J. Choate, J.E. Fast, W.K. Hensley, R.T. Kouzes, J.E. Schweppe, Comparison of LaBr3: Ce and NAI(Tl) scintillators for radio-isotope identification devices, Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip. 572 (2) (2007) 774-784.   DOI