Browse > Article
http://dx.doi.org/10.5516/NET.03.2011.030

DESIGN SCOPE AND LEVEL FOR STANDARD DESIGN CERTIFICATION UNDER A TWO STEP LICENSING PROCESS  

Suh, Nam-Duk (Korea Institute of Nuclear Safety)
Huh, Chang-Wook (Korea Institute of Nuclear Safety)
Publication Information
Nuclear Engineering and Technology / v.44, no.6, 2012 , pp. 689-696 More about this Journal
Abstract
A small integral reactor SMART (System Integrated Modular Advanced ReacTor), being developed in Korea since late 1990s and targeted to obtaining a standard design approval by the end of 2011, is introduced. The design scope and level for design certification (DC) is well described in the U.S. NRC SECY documents published the early 1990s. However, the documents are valid for a one-step licensing process called a combined operating license (COL) by the U.S. NRC, while Korea still uses a two-step licensing process. Thus, referencing the concept of the SECY documents, we have established the design scope and level for the SMART DC using the contexts of the standard review plan (SRP). Some examples of the results and issues raised during our review are briefly presented in this paper. The same methodology will be applied to other types of reactor under development in Korea, such as future VHTR reactors.
Keywords
Design Level; Design Scope; Design Certification; COL; Two Step Licensing Process;
Citations & Related Records

Times Cited By Web Of Science : 0
연도 인용수 순위
  • Reference
1 Korea Atomic Energy Research Institute, "SMART Top Tier Requirements", 2009.5.
2 Korea Atomic Energy Research Institute, "Development of a Phenomena Identification and Ranking Table (PIRT) of Thermal Hydraulic Phenomena for SMART" , 2009.6.
3 Korea Atomic Energy Research Institute, "SMART NSSS Design Bases", 2009.7.
4 SECY-90-241, "Level of Detail Required for Design Certification under Part 52", U.S. NRC, July, 1990
5 SECY-90-377, "Requirements for Design Certification under 10CFR Part 52", U.S. NRC, November, 1990
6 Regulatory Guide 1.206, "Combined License Applications for Nuclear Power Plants", U.S. NRC, June, 2007