Browse > Article
http://dx.doi.org/10.5516/NET.2009.41.8.1053

DEVELOPMENT OF A TWO-DIMENSIONAL THERMOHYDRAULIC HOT POOL MODEL AND ITS EFFECTS ON REACTIVITY FEEDBACK DURING A UTOP IN LIQUID METAL REACTORS  

Lee, Yong-Bum (Korea Atomic Energy Research Institute)
Jeong, Hae-Yong (Korea Atomic Energy Research Institute)
Cho, Chung-Ho (Korea Atomic Energy Research Institute)
Kwon, Young-Min (Korea Atomic Energy Research Institute)
Ha, Kwi-Seok (Korea Atomic Energy Research Institute)
Chang, Won-Pyo (Korea Atomic Energy Research Institute)
Suk, Soo-Dong (Korea Atomic Energy Research Institute)
Hahn, Do-Hee (Korea Atomic Energy Research Institute)
Publication Information
Nuclear Engineering and Technology / v.41, no.8, 2009 , pp. 1053-1064 More about this Journal
Abstract
The existence of a large sodium pool in the KALIMER, a pool-type LMR developed by the Korea Atomic Energy Research Institute, plays an important role in reactor safety and operability because it determines the grace time for operators to cope with an abnormal event and to terminate a transient before reactor enters into an accident condition. A two-dimensional hot pool model has been developed and implemented in the SSC-K code, and has been successfully applied for the assessment of safety issues in the conceptual design of KALIMER and for the analysis of anticipated system transients. The other important models of the SSC-K code include a three-dimensional core thermal-hydraulic model, a reactivity model, a passive decay heat removal system model, and an intermediate heat transport system and steam generation system model. The capability of the developed two-dimensional hot pool model was evaluated with a comparison of the temperature distribution calculated with the CFX code. The predicted hot pool coolant temperature distributions obtained with the two-dimensional hot pool model agreed well with those predicted with the CFX code. Variations in the temperature distribution of the hot pool affect the reactivity feedback due to an expansion of the control rod drive line (CRDL) immersed in the pool. The existing CRDL reactivity model of the SSC-K code has been modified based on the detailed hot pool temperature distribution obtained with the two-dimensional pool model. An analysis of an unprotected transient over power with the modified reactivity model showed an improved negative reactivity feedback effect.
Keywords
Hot Pool Model; Reactivity Feedback; Control Rod Drive Line; Unprotected Transient over Power;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
Times Cited By Web Of Science : 0  (Related Records In Web of Science)
Times Cited By SCOPUS : 0
연도 인용수 순위
1 Hahn, D. et al., 2002, KALIMER Conceptual Design Report, KAERI/TR-2204/2002. KAERI
2 Chang, W.P., Kwon, Y. M., Lee, Y. B., and Hahn, D., 2002, Model Development for Analysis of the Korea Advanced Liquid Metal Reactor, Nuclear Engineering and Design, Vol.217, pp.63-80   DOI   ScienceOn
3 Lee, Y. B., Chang, W. P., Kwon, Y. M., Jeong, K. S., and Hahn, D., 2001, Development of a Two-Dimensional Model for the Thermo-hydraulic Analysis of the Hot Pool in Liquid Metal Reactors, Annals of Nuclear Energy Vol.29, pp.21-40   DOI   ScienceOn
4 Van Doormal, J. P. and Raithby, G. D., 1984, Enhancements of the SIMPLE Method for Predicting Incompressible Fluid Flows, Numerical Heat Transfer, Vol. 7, pp. 147-163   DOI   ScienceOn
5 Hahn, D., Kim, Y. I., Lee, C. B., Kim, S. O., Lee, J. H., Lee, Y. B., Kim, B. H., and Jeong, H. Y., 2007, Conceptual Design of the Sodium-Cooled Fast Reactor KALIMER-600, Nuclear Engineering and Technology, Vol. 39, No. 3, pp.205-218
6 CFX Ltd., 2003, CFX Version 5.6 User's Manual
7 Lyon, R. N., 1951, Liquid metal heat transfer coefficients, Chem. Eng. Prog. Vol. 47, No. 2, pp.75-79
8 Kim, K. D., Kwon, Y. M., Chang, W. P., and Hahn, D., 1998, Review of Existing Models and New Models for SSC-K Code, KAERI/TR-990/98
9 Kwon, Y.M., Lee, Y. B., Chang, W. P., Hahn, D., and Kim, K. D., 2001, Development of a System Analysis Code, SSC-K, for Inherent Safety Evaluation of the Korea Advanced Liquid Metal Reactor, Journal of the Korean Nuclear Society, Vol.33, No.2, pp.209-224
10 Agrawal, A. K. et at., 1973, An Advanced Thermohydraulic Simulation Code for Transients in LMFBRs (SSC-L Code), BNL-NUREG-50773, Brookhaven National Laboratory
11 Cahalan, J. E., Tentner, A. M., and Morris, E. E., 1994, Advanced LMR Safety Analysis Capabilities in the SASSYS-1 and SAS4A Computer Codes, Proceedings of the Int. Topical Meeting on Advanced Reactor Safety, Pittsburgh, Pennsylvania, 17-21 April, ANS
12 Zhu, J., 1991, A Low-Diffusive and Oscillation Free Convection Schemes, Communications in Applied Numerical Methods, Vol. 7, pp. 225-232   DOI   ScienceOn
13 Kwon, Y.M., Jeong, H. Y., Ha, K. S., Chang, W. P., Lee, Y. B., and Hahn, D., 2005, Evaluation of the Inherent Safety of the KALIMER-150 Design Using the SAS4A/SASSYS-1 Computer Code, KAERI/TR-2935/2005