Wear of UHMWPE Pins Against Ti-alloy and Stainless Steel Disks Moving in Two Kinematic Motions  

이권용 (세종대학교 기계항공우주공학부)
김석영 (영남대학교 금속 및 재료공학부)
김신윤 (경북대학교 정형외과학교실)
Publication Information
Tribology and Lubricants / v.18, no.2, 2002 , pp. 167-172 More about this Journal
Abstract
The wear behaviors of ultrahigh molecular weight polyethylene pins against titanium alloy and stainless steel disks moving in two different kinematic motion were investigated by conducting repeat pass rotational sliding and linear reciprocal sliding wear tests. Linear reciprocal motion wore more the polyethylene pin than did repeat pass rotational motion for both disk materials. It means that the repeated directional change of contact stresses generates more wear debris in polyethylene. For the linear reciprocal sliding tests, titanium alloy disks were damaged with some scratches after one million cycles but no surface damage was observed on the polyethylene pins. On the other hand, fur the repeat pass rotational sliding tests, all titanium alloy disks were severely abraded on the entire region of sliding track. This phenomenon can be interpreted by that stress fatigue under repeated sliding contact initiated titanium oxide layer wear particles from disk surface, and these hard particles were embedded into polyethylene pin and then they severely abraded the disk surface. From these results it can be concluded that the kinematic motion in pin-on-disk wear tests play a crucial role on the wear behaviors of UHMWPE pins against titanium alloy and stainless steef discs.
Keywords
wear; kinematic motion; UUMWPE; Ti-alloy; stainless steel.;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Mechanism and clinical significance of wear debris-induced osteolysis /
[ H.C. Amstutz;P. Cambell;N. Kossovsky;I.C. Clarke ] / Clin. Orthop.
2 Wear-accelerated corrosion of Ti6Al4V and nitrogenion-implanted Ti6Al4V: Mechanisms and influence of fixed-stress magnitude /
[ R.A. Buchanan;E.D. Rigney, Jr.;J.M. Williams ] / J. Biomed. Mater. Res.   DOI   ScienceOn
3 Shapes and dimensional characteristics of polyethylene wear particles generated in vivo by total knee replacements compared to total hip replacements /
[ T.P. Schmalzried;P. Cambell;A.K. Schmitt;I.C. Brown;H.C. Amstutz ] / J. Biomed. Mater. Res. (Appl. Biomater.)   DOI   ScienceOn
4 The importance of multidirectional motion on the wear of polyethylene /
[ C.R. Bragdon;D.O. O'Connor;J.D. Lowenstein;M. Jasty;W.D. Syniuta ] / Proc. Instn. Mech. Engrs., Part H: J. Eng. Med.
5 In vivo wear of Ti6Al4V femoral heads: A retrieval study /
[ T.E. McGovern;J. Black;J.J. Jacobs;R.M. Graham;M. LaBerge ] / J. Biomed. Mater. Res.   DOI   ScienceOn
6 In vivo wear of polyethylene acetabular components /
[ J.M. Kabo;J.S. Gebhard;G. Loren;H.C. Amstutz ] / J. Bone Joint Surg.
7 A tribological study of retrieved hip prostheses /
[ G.H. Isaac;B.M. Wroblewski;J.R. Atkinson;D. Dowson ] / Clin. Orthop.
8 Digital edge-detection measurement of polyethylene wear after total hip arthroplasty /
[ C.M. Shaver;T.D. Brown;S.L. Hillis;J.J. Callaghan ] / J. Bone Joint Surg.
9 A multidirectional motion pin-on-disk wear test method for prosthetic joint materials /
[ V. Saikko ] / J. Biomed. Mater. Res.   DOI   ScienceOn
10 Wear of shelf-aged UHMWPE acetabular liners /
[ K.Y. Lee;K.H. Lee ] / Wear   DOI   ScienceOn
11 Measurement of polyethylene wear in metal-backed acetabular cups,Ⅱ. Clinical application /
[ P.A. Devane;R.B. Bourne;C.H. Rorabeck;S. MacDonald;E.J. Robinson ] / Clin. Orthop.
12 Composition and morphology of wear debris in failed uncemented total hip replacement /
[ A.S. Shanbhag;J.J. Jacobs;T.T. Glant;J.L. Gilbert;J. Black;J.O. Galante ] / J. Bone Joint Surg.
13 Mechanistic and morphological origins of ultra-high molecular weight polyethylene wear debris in total joint replacement prostheses /
[ A. Wang;C. Stark;J.H. Dumbleton ] / Proc. Instn. Mech. Engrs., Part H: J. Eng. Med.   DOI   ScienceOn
14 Measurement of polyethylene wear in acetabular components inserted with and without cement, A randomized trial /
[ P.A. Devane;E.J. Robinson;R. B. Bourne;C.H. Rorabeck;N.N. Nayak;J.G. Horne ] / J. Bone Joint Surg.
15 The problem in total joint arthropalsty: Aseptic loosening [Editorial] /
[ S.R. Goldring;C.R. Clark;T.M. Wright ] / J. Bone Joint Surg.
16 Periprosthetic osteolysis in total hip arthroplasty: the role of particulate wear debris /
[ W.J. Maloney;R.L. Smith ] / J. Bone Joint Surg.
17 Wear of polyethylene cups in total hip arthroplasty /
[ C.J. Sychterz;K.H. Moon;Y. Hashimoto;K.M. Terefenko;C.A. Engh. Jr.;T.W. Bauer ] / J. Bone Joint Surg.
18 Orientation softening in the deformation and wear of ultra-high molecular weight polyethylene /
[ A. Wang;D.C. Sun;S.S. Yau;B. Edwards;M. Sokol;A. Essner;V.K. Polineni;C. Stark;J.H. Dumbleton ] / Wear   DOI