Browse > Article

Development of Solenoid Operated Valve for Nuclear Power Plant  

Lim, B.J. (한국기계연구원)
Park, C.D. (한국기계연구원)
Chung, K.Y. (한국기계연구원)
Yun, S.N. (한국기계연구원)
Publication Information
Journal of Drive and Control / v.11, no.1, 2014 , pp. 26-34 More about this Journal
Keywords
Citations & Related Records
연도 인용수 순위
  • Reference
1 Technical Report, 2009, "Technical Report of Solenoid Valve"
2 C. D. Park, B. J. Lim, and K. Y. Chung, Design process of solenoid valve for nuclear power plant, NTHAS 8, Beppu, Japan (2012) 9-12.
3 IEEE Std 382, 2006, "Qualification of actuators for power-operated valve assemblies with safety-related functions for nuclear power plants"
4 Park C.D., Lim, B. J., Song C.S., 2006, "Methodology for modification of LOCA environmental test profile", NTHAS5
5 Lim, B. J., Song C.S., Park C.D., KIM S. Y., Roh H., B., Lee H. S., 2005 "LOCA Test of Class 1E Cables Using Modified LOCA Profile", Transactions of the Korean Nuclear Society Autumn Meeting