The Instrument Channel setpoints of the Reactor Protection System(RPS) and the Engineered Safety Feature Actuation System(ESFAS) ensures the safety of Nuclear Power Plants (NPPs), and the actuation of the protection system should be guaranteed on power change condition. The goal of this study is to verify the appropriateness of the sensor drift and rack drift which are important factors for setpoints evaluation and to improve the setpoints margin using the operation data, design specifications and operation manuals of the NPPS.
Keywords
Citations & Related Records
연도 인용수 순위
  • Reference
1 On-Line Monitoring of Instrument Channel Performance, Volume 3: Applications to Nuclear Power Plant Technical Specification Instrumentation, EPRI : 2004.12. 1007930.
2 Modern Statistics for Business and Economics Using Microsoft Excel Rev 2, Bumjo Park, 2003.
3 Setpoints for Nuclear Safety-Related Instrumen tation, May 2006, ISA, ISA-RP67.04.01-2006
4 Methodologies for the Determination of Setpoints for Nuclear Safety-Related Instrumentation, January 2000, ISA, ISA-RP67.04.02-2000