Browse > Article
http://dx.doi.org/10.5293/kfma.2012.15.5.005

Complete Characteristic Curve for a Reactor Coolant Pump  

Yoo, IlSu (한국기계연구원 극한기계부품연구본부)
Park, MuRyong (한국기계연구원 극한기계부품연구본부)
Hwang, SoonChan (한국기계연구원 극한기계부품연구본부)
Yoon, EuiSoo (한국기계연구원 극한기계부품연구본부)
Publication Information
Abstract
An experimental test facility for the complete characteristics of pumps is constructed at KIMM(Korea Institute of Machinery and Materials). All sensors instrumented in test facility for measuring flow rate, pressure, force and moment are in-situ calibrated by primary method. This paper describes the test facility and test technique of the complete characteristics of pumps, together with an experimental test results for a reactor coolant pump which is designed at KIMM for the first time in Korea. The test results for the mixed-flow type pump of $n_s$=1.425 are presented by three curves: constant head, torque, and speed.
Keywords
Complete characteristics; Mized-flow pump; Reactor coolant pump;
Citations & Related Records
연도 인용수 순위
  • Reference
1 IEC 60193, 1999, Hydraulic Turbines, Storage Pumps and Pump-Turbines-Model Acceptance Tests.
2 Knapp, R. T., 1937, "Complete Characteristics of Centrifugal Pumps and Their Use in Prediction of Transient Behavior," Trans. ASME, Vol. 59, pp. 683-689.
3 Martin, C. S., 1983, "Representation of Pump Characteristics for Transient Analysis," ASME Symposium of Performance Characteristics of Hydraulic Turbines and Pumps, November 13-18, pp. 1-13.
4 KS B IEC 61364, 2006, 수력발전소 기계류의 작성법.
5 KS B 6301, 2001, 원심펌프, 사류펌프 및 축류펌프의 시험 및 검사 방법.