Abstract
This study was conducted to evaluate the feasibility of identifying freshness of beef using a surface acoustic wave (SAW) sensor based electronic nose. The beef was stored at 5$^{\circ}C$ and aroma was measured with the passage of time. Chromatographic analysis of the odor showed that number of volatile components and their amounts were rapidly increased after 19 days of storage. Classifying beefs according to their storage days was possible using principle component analysis (PCA). Classifying beefs processed from four different origins was also possible with PCA analysis of odor. This study shows that electronic nose can be applied to beef freshness evaluation and classification of its origin.
Keywords
Electronic nose; SAW sensor; Beef freshness;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Arnold, J. W. and S. D. Senter. 1998. Use of digital aroma technology and SPME GC-MS to compare volatile compounds produced by bacteria isolated from processed poultry. Journal of the Science of Food and Agriculture, 78(3):343-348   DOI
2 Blixt, Y. and E. Borch. 1999. Using an electronic nose for determining the spoilage of vacuum-packaged beef. International Journal of Food Microbiology 46, 123-134   DOI   ScienceOn
3 Staples, E. J., T. Matsuda and S. Viswanathan. 1998. Real Time Environmental Screening of Air, Water and Soil Matrices Using a novel Field Portable GC / SAW System. Environmental Strategies for the 21st Century, Asia Pacific Conference, 8-10 April 1998, Singapore
4 Schnurer, J., J. Olsson and T. BoIjesson. 1999. Fungal volatiles as indicators of food and feeds spoilage. Fungal Genetics and Biology 27, 209-217   DOI   ScienceOn
5 Keshri, G., N. Magan and P. Voysey. 1998. Use of an electronic nose for early detection and differentiation between spoilage fungi, Letters in Applied Microbiology 27(5):261-264
6 Natale, C. D., G. Olafsdottir, S. Einarsson, E. Martinelli, R. Paolesse and A. D'Amico. 2001. Comparison and integration of different electronic noses for freshness evaluation of cod-fish fillets. Sensors and Actuators B 77, 572-578   DOI   ScienceOn
7 McEntegart, C. M., W. R. Penrose, S. Strathmann and J. R. Stetter. 2000. Detection and discrimination of coliform bacteria with gas sensor arrays. Sensors and Actuators B 70, 170-176   DOI   ScienceOn
8 Yano, Y., N. Miyaguchi, M. Watanabe, T. Nakamura, T. Youdou, J. Miyai, M. Numata and Y. Asano. 1996. Monitoring of beef aging using a two-line flow injection analysis biosensor consisting of putrescine and xan-thine electrodes. Food Research International, 28(6): 611-617   DOI   ScienceOn