Abstract
Recently, geotextile tube method can be widely applied to the river, costal and marine in the construction field, such as embankment, groin, breakwater, dyke structures and so on, in advanced countries of the world. And that has been constructed at the temporary road for incheon, ilsan-bridge construction and coast erosion protection in republic of korea. Geotextile tube is a tube shaped geotextile product and hydraulic pumping filled with dredged soils. In this paper, the numerical analysis was performed to investigate the behavior of geotextile tube with various properties of material character, shape condition, construction pressure and so on. Also, the field test was conducted in order to identify the construction ability of Samangum waterproof embankment using geotextile tube. According to the applied of field test, geotextile tube was 65 m long and 4.0 m diameter. Also, the permeability coefficient and ultimate tensile strength of geotextile tube is $1.6{\times}10^{-1}$ cm/sec and 205.26 kN/m, respectively. As a result of filed test, when filled, geotextile tube does not attain the same as its unfilled theoretical diameter, but may reach approximately of 55 percent of the theoretical diameter. At the time, geotextile tubes were 12.56 m in circumference and filled to a height of about 2.2 m. This paper presents case study on field application and behavior analysis of the saemangum waterproof embankment donggin 1 division construction using geotextile tube.
Keywords
geotextile tube; ultimate tensile strength; dredged soils; dyke; permeability coefficient;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 Caroll, R. P., 1994. Submerged geotextile flexible forms using noncircular cylindrical shapes. Geotechnical Fabrics Report. Industrial Fabric Association International, St. Paul, MN 12(8): 4-15.
2 Chang, Y. C., K. Y. Son, S. E. Lee, S. J. Kim, and S. W. Kim, 2012. Behavior of geotextile tube for erosion control. Journal of the Korean Geotechnical Society 28(5): 5-12 (in Korean).   과학기술학회마을   DOI   ScienceOn
3 Cho, S. D, 2000. Application and evaluation of geotextile container method. 2000 Special Seminar on Geosynthetics: 19-33 (in Korean).
4 Kazimierowicz, K., 1994. Simple analysis of deformation of sand-sausages. Proceeding of 5th International Conference on Geotextile, Geomembranes and Related Products, Singapore 2: 775-778.
5 Kim, H. T., J. Y. Yoo, and Y. I. Oh, 2007. Case history of sea dyke filter construction using geotextile tube mattress. Journal of the Korean Geosynthetics Society 06(01): 9-16 (in Korean).   과학기술학회마을
6 Koerner, R. M., 1994. Designing with geosynthetic. 3rd Ed. Prentice-Hall, Eaglewood Cliffs, New Jersy: 1-66, 95-105, 263-269.
7 Leshchinsky, Dov and Leshchinsky, Ora, 1996. Geosythetic confined pressurized slurry (GeoCoPS); supplement notes for version 1.0. US Army Corps of Engineers Waterways Experiment Station, Vicksburg, MS.
8 Liu, G. S., 1981. Design criteria of sand sausages for beach defense. Proceedings of 19th Congress of the International Association for Hydraulic Research, New Delhi, India 3: 123-131.
9 Oh, Y. I. and E. C. Shin, 2003. Behavior of geotextile tube by plane strain analysis and 3-dimensional finite element method. Journal of the Korean Geotechnical Society 19(5): 233-241 (in Korean).   과학기술학회마을
10 Pilarczyk, K. W., 1995. Geotextile systems for coastal protection an overview. Proceedings 4th International Conference on Coastal and Port Engineering in Developing Countries, Rio De Janeiro.
11 Shin, E. C., Y. I. Oh, and S. Y. Kim, 2002. Hydrodynamic behavior analysis of stacked geotextile tube by hydraulic model tests. The Fall 2002 Geotechnical Conference 10: 705-712 (in Korean).
12 Silverster, R., 1986. Use of grout-filled gausages in coastal structures. Proceedings of Waterway, Port, Coastal and Ocean Engineering, ASCE 112(1): 95-114.
13 Silverster, R., 1990. Flexible membrane units for breakwater. Handbook of Coastal and Ocean Engineering, J. B. Herbich, Ed, Gulf, Houston 1: 921-938.