Browse > Article

The Strain of Pipe Framed Greenhouse by Typhoon  

Suh, Won-Myung (경상대학교 농과대학 농업시스템공학부(농업생명과학연구원))
Yoon, Yong-Cheol (경상대학교 농과대학 농업시스템공학부(농업생명과학연구원))
Publication Information
Magazine of the Korean Society of Agricultural Engineers / v.44, no.4, 2002 , pp. 99-106 More about this Journal
Abstract
This research was performed to study the actual behavior of 1-2W type pipe greenhouse under the influence of typhoon by measuring the various strains in structural materials. These results can eventually be utilized in the design criteria as well as in the modification of conventional equation for calculating more realistic wind loads. The first data under the influence of Typhoon Olga arrived in Jinju on Aug. 1999 were obtained by strain gage with 10 sensor points. According to the data obtained, the typical variation of strain depending on wind pattern could be observed. The strains in structural frame were fluctuated very sensitively depending on the direction and magnitude of wind velocity. But some of the data were lost or missed by system's failure. A kind of inherent vibration pattern of greenhouse pipe frame was observed from the plotted data, but this phenomenon is not so clear as to be separated from the overall fluctuation so far. This experimental research is expected to be continued as a long term project to measure and analyze the strain pattern of structural frame depending on the various locations and section characteristics by way of adopting more efficient instrument with sufficient number of measuring points and accuracy.
Keywords
Pipe greenhouse; Natural disaster; Wind load; Strain; Typhoon Olga;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Nam, S. W. 2001. Experimental analysis on yield strength of pipe connectors and joints for pipe framed greenhouses. J. of KSAE 43(6) : 113-119. (in Korean)
2 J. of KSAM. 1987. Measurement and Utilization Technology of Microcomputer. J. of KSAM. (in Korean)
3 Yoon, Y. C., W. M. Shu and Y. S. Yoon. 1995. A study on the typhoon disaster of greenhouse. J. of Biological Production Facilities & Environmental Control 4(2): 167-174. (in Korean)
4 Lee, S. G., 1995. Structural design of plastic greenhouse for prevention of meteorological disaster. 5-7. Cyeongbuk : Agricultural Research and Extension Services. (in Korean)
5 Gyeongsangnam-do. 1999. Support plan for agricultural disaster. (in Korean)
6 Window, A. L., 1992. Strain Gauge Technology. London. Elsevier applied science
7 Nam, S. W., 2001. A study on the standard durable years of pipe framed greenhouses. J. of KSAE 43(1) : 96-101. (in Korean)
8 Yoon, Y. C., 1994. The experimental study on uplift resistance of greenhouse individual piles. Ph. D. Japan. Ehime University