Browse > Article
http://dx.doi.org/10.7746/jkros.2017.12.3.322

A Robotic Medical Palpation using Contact Pressure Distribution  

Kim, Hyoungkyun (Mechanical Engineering, POSTECH)
Choi, Seungmoon (Computer Science and Engineering, POSTECH)
Chung, Wan Kyun (Mechanical Engineering, POSTECH)
Publication Information
The Journal of Korea Robotics Society / v.12, no.3, 2017 , pp. 322-331 More about this Journal
Abstract
In this paper we present a novel robotic palpation method for the lump shape estimation using contact pressure distribution. Many previous researches about the robotic palpation have used a stiffness map, which is not suitable to obtain geometrical information of a lump. As a result, they require a large data set and long palpation time to estimate the lump shape. Instead of using the stiffness map, the proposed palpation method uses the difference between the normal force direction and the surface normal to detect the lump boundary and estimate its normal. The palpation trajectory is generated by the normal of the lump boundary to track the lump boundary in real-time. The proposed approach requires small data set and short palpation time for the lump shape estimation since the shape can be directly estimated from the optimally generated palpation trajectory. An experiment result shows that our method can find the lump shape accurately in real-time with small data and short time.
Keywords
Tactile Sensing; Medical Robot; Medical Palpation;
Citations & Related Records
연도 인용수 순위
  • Reference
1 R. Harris and L.S. Kinsinger, "Routinely teaching breast selfexamination is dead. What does this mean?," J. Natl. Cancer I., vol. 94, no. 19, pp. 1420-1421, Oct., 2002.   DOI
2 M.V. Ottermo, M. Vstedal, T. Lang, Stavdahl, Y. Yavuz, T. Johansen, and R. Marvik, "The role of tactile feedback in laparoscopic surgery," Surg. Laparo. Endo. Per., vol. 16, no. 6, pp. 390-400, Dec., 2006.   DOI
3 A. Talasaz and R.V. Patel, "Telerobotic palpation for tumor localization with depth estimation", in Proc. of IEEE/RSJ IROS 2013, Tokyo, Japan, pp. 463-468, 2013.
4 M. Beccani, C.D. Natali, M.E. Rentschler, and P. Valdastri, "Wireless tissue palpation: proof of concept for a single degree of freedom," in Proc. of IEEE ICRA 2013, Karlsruhe, Germany, pp. 711-717, 2013.
5 M. Beccani, C.D. Natali, L.J. Sliker, J.A. Schoen, M.E. Rentschler, and P. Valdastri, "Wireless tissue palpation for intraoperative detection of lumps in the soft tissue," IEEE Trans. Biomed. Eng., vol. 61, no. 2, pp. 353-361, Aug., 2014.   DOI
6 I.B. Wanninayake, L.D. Seneviratne, and K. Althoefer, "Novel indentation depth measuring system for stiffness characterization in soft tissue palpation," in Proc. of IEEE ICRA 2012, Minnesota, USA, pp. 4648-4653, 2012.
7 I.B. Wanninayake, L.D. Seneviratne, and K. Althoefer, "Estimation of tissue stiffness using a prototype of air-float stiffness probe," in Proc. of IEEE ICRA 2014, Hong Kong, China, pp. 1426-1431, 2014.
8 K.A. Nichols and A.M. Okamura, "Methods to segment hard inclusions in soft tissue during autonomous robotic palpation," IEEE Trans. Robot, vol. 31, no. 2, pp. 344-354, Mar., 2015.   DOI
9 H. Kim, S. Choi, and W. K. Chung, "Feasibility of a novel indicator for lump detection using contact pressure distribution," in Proc. of IEEE/RSJ IROS 2015, Hamburg, Germany, pp. 2111-2117, 2015.
10 H. Kim, S. Choi, and W. K. Chung, "Contact force decomposition using contact pressure distribution," IEEE RA-L, vol. 2, no. 1, pp. 290-297, Jan., 2017.