Browse > Article
http://dx.doi.org/10.4333/KPS.2006.36.4.277

Bioequivalence of Lisihexal® tablet to Zestril® tablet(Lisinopril 10 mg)  

Oh, Soo-Yeon (Department of Pharmacology, College of Medicine, Dankook University)
Aryal Dipendra Kumar (Department of Pharmacology, College of Medicine, Dankook University)
Cho, Jong-Tae (Department of Internal Medicine, College of Medicine, Dankook University)
Kim, Hyung-Gun (Department of Pharmacology, College of Medicine, Dankook University)
Kim, Yoon-Gyoon (Department of Pharmacology, College of Medicine, Dankook University)
Publication Information
Journal of Pharmaceutical Investigation / v.36, no.4, 2006 , pp. 277-282 More about this Journal
Abstract
Lisinopril is one of the angiotensin-converting enzyme inhibitors, which have been used for treatment of hypertension and heart failure. The aim of this study was to evaluate the bioequivalence of two lisinopril tablet, $Lisihexal^{\circledR}$ and $Zestril^{\circledR}$ as a test and reference, respectively. The study was came out on 28 healthy male Korean volunteers in $2{\times}2$ crossover design. An analytical method with LC-MS-MS was developed for the quantification of lisinopril and enalapril(IS) using SPE method. The condition was selective, sensitive and precise in human plasma, that was enough for the pharmacokinetic study of lisinopril. The pharmacokinetic parameters such as $AUC_t,\;AUC_{inf},\;C_{max},\;T_{max}\;and\;t_{1/2}$ were calculated and ANOVA test was used for the statistical analysis of the parameters using log transformed $AUC_t,\;AUC_{inf}\;and\;C_{max}$. $t_{1/2}$ of test and reference drugs were calculated $11.4{\pm}5.1\;and\;16.1{\pm}9.9\;hr$, respectively. The 90% confidence intervals of $AUC_t,\;AUC_{inf}\;and\;C_{max}$ were log 0.9245$\sim$log 1.0603, log 0.9270$\sim$log 1.0601 and log 0.9548$\sim$log 1.1009, within the acceptable range of log 0.8 to log 1.25 by KFDA bioequivalence criteria. Two medications of lisinopril were evaluated bioequivalent and thus may be prescribed interchangeably.
Keywords
Lisinopril; Enalapril; Bioequivalence; LC-MS-MS;
Citations & Related Records
연도 인용수 순위
  • Reference
1 식품의약품안전청 고시 제 2002-60호(2002. 11. 22). 생물학적동등성시험 기준
2 M. Georgarakis, A. Tsakalof, F. Zougrou, G. Kontopoulos and I. Tsiptsios, Evaluation of the bioequivalence and pharmacokinetics of two lisinopril tablet formulations after single oral administration in healthy volunteers, Arzneimittel- forschung, 54(1), 15-19 (2004)
3 A.A.F. Padua, R.E. Barrientos-Astigarraga, V.M. Rezende, G.D. Mendes and G. De Nucci, Lisinopril quantification in human plasma by liquid chromatography-electrospray tandem mass spectrometry, J. Chromatogr. B, 809, 211-216 (2004)   DOI   ScienceOn
4 S.C. Sweetman (Ed.), Martindale, The complete drug reference, 33th ed, Pharmaceutical Press. London, U.K., pp. 921 (2002)
5 A.R. Gascon, A. Cuadrado, M.A. Solinis, R.M. Hernandez, E. Ramirez, R. Dalmau and J.L. Pedraz, Comparative bioavailability of two immediate-release tablets of lisinopril/hydrochlorothiazide in healthy volunteers, Int. J. Clin. Pharmacol. Ther., 41, 309-315 (2003)   DOI
6 A.S. Yuan and J.D. Gilbert, Time-resolved fluoroimmuno- assay for the determination of lisinopril and enalaprilat in human serum, J. Pharm. Biomed. Anal., 14(7), 773-781 (1996)   DOI   ScienceOn
7 Y.C. Wong and B.G. Charles, Determination of the angio- tensin-converting enzyme inhibitor lisinopril in urine using solid-phase extraction and reversed-phase high-performance liquid chromatography, J. Chromatogr. B, 673(2), 306-310 (1995)   DOI   ScienceOn
8 A. Tsakalof, K. Bairachtari and M. Georgarakis, Develop- ment of a liquid chromatography-mass spectrometry method for monitoring the angiotensin-converting enzyme inhibitor lisinopril in serum, J. Chromatogr. B, 783, 425-432 (2003)   DOI   ScienceOn
9 H.J. Leis, G. Fauler, G. Raspotnig and W. Windischhofer, An improved method for the measurement of the angiotensin-converting enzyme inhibitor lisinopril in human plasma by stable isotope dilution gas chromatography/negative ion chemical ionization mass spectrometry, Rapid Commun. Mass Spectrom., 13(8), 650-653 (1999)   DOI   ScienceOn
10 생물학적동등성시험 표준지침, 식품의약품안전청 국립독성연구원, pp. 30-34 (2003)
11 P.J. Worland and B. Jarrott, Radioimmunoassay for the quantitation of lisinopril and enalaprilat, J. Pharm. Sci., 75(5), 512-516 (1986)   DOI
12 O. Sgirli and L. Ersoy, An HPLC method for the determination of lisinopril in human plasma and urine with fluorescence detection, J. Chromatogr. B, 809, 159-165 (2004)   DOI   ScienceOn