Browse > Article
http://dx.doi.org/10.12989/sss.2021.27.2.319

Detecting and localizing anomalies on masonry towers from low-cost vibration monitoring  

Borlenghi, Paolo (Department of Architecture, Built environment and Construction engineering (ABC), Politecnico di Milano)
Gentile, Carmelo (Department of Architecture, Built environment and Construction engineering (ABC), Politecnico di Milano)
Saisi, Antonella (Department of Architecture, Built environment and Construction engineering (ABC), Politecnico di Milano)
Publication Information
Smart Structures and Systems / v.27, no.2, 2021 , pp. 319-333 More about this Journal
Abstract
The structural health of masonry towers can be monitored by installing few accelerometers (or seismometers) at the top of the building. This cost-effective setup provides continuous and reliable information on the natural frequencies of the structure and allows to detect the occurrence of structural anomalies; however, to move from anomaly detection to localization with such a simplified distribution of sensors, a calibrated numerical model is needed. The paper summarizes the development of a Structural Health Monitoring (SHM) procedure for the model-based damage assessment in masonry towers using frequency data. The proposed methodology involves the subsequent steps: (i) preliminary analysis including geometric survey and ambient vibration tests; (ii) FE modeling and updating based on the identified modal parameters; (iii) creation of a Damage Location Reference Matrix (DLRM) from numerically simulated damage scenarios; (iv) detection of the onset of damage from the analysis of the continuously collected vibration data, and (v) localization of the anomalies through the comparison between the experimentally identified variations of natural frequencies and the above-defined DLRM matrix. The proposed SHM methodology is exemplified on the ancient Zuccaro tower in Mantua, Italy. Pseudo-experimental monitoring data were generated and employed to assess the reliability of the developed algorithm in identifying the damage location. The results show a promise toward the practical applications of the proposed strategy for the early identification of damage in ancient towers.
Keywords
damage localization; masonry tower; model updating; historical constructions; structural health monitoring;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Saisi, A., Terenzoni, S., Ruccolo, A. and Gentile, C. (2019), "Safety of the architectural heritage: structural assessment of the Zuccaro's tower in Mantua", in Aguilar R. et al. (ed.), In: Structural Analysis of Historical Constructions, RILEM Bookseries, 18, 2422-2430. https://doi.org/10.1007/978-3-319-99441-3_260
2 Standoli, G., Giordano, E., Milani, G. and Clementi, F. (2020), "Model updating of historical belfries based on OMA identification techniques", Int. J. Archit. Herit., [In press] https://doi.org/10.1080/15583058.2020.1723735   DOI
3 Structural Vibration Solutions (2012), ARTeMIS Extractor Pro 2011, Aalborg, Denmark.
4 Ubertini, F., Cavalagli, N., Kita, A. and Comanducci, G. (2018), "Assessment of a monumental masonry bell-tower after 2016 central Italy seismic sequence by long-term SHM", Bull. Earthquake Eng., 16(2), 775-801. https://doi.org/10.1007/s10518-017-0222-7   DOI
5 Valente, M. and Milani, G. (2016), "Seismic assessment of historical masonry towers by means of simplified approaches and standard FEM", Constr. Build. Mater., 108, 74-104. https://doi.org/10.1016/j.conbuildmat.2016.01.025   DOI
6 van Overschee, P. and de Moor, B. (1996), Subspace Identification for Linear Systems: Theory, Implementation, Applications, Kluwer Academic Publishers, Dordrecht, The Netherlands.
7 Yan, A.-M., Kerschen, G., De Boe, P. and Golinval, J.-C. (2005), "Structural damage diagnosis under varying environmental conditions - Part I: A linear analysis", Mech. Syst. Signal Process., 19(4), 847-864. https://doi.org/10.1016/j.ymssp.2004.12.002   DOI
8 Zonno, G., Aguilar, R., Boroschek, R. and Lourenco, P.B. (2019), "Analysis of the long and short-term effects of temperature and humidity on the structural properties of adobe buildings using continuous monitoring", Eng. Struct., 196, 109299. https://doi.org/10.1016/j.engstruct.2019.109299.   DOI
9 Allemang, R.J. and Brown, D.L. (1982), "Correlation coefficient for modal vector analysis", Proceedings of the 1st International Modal Analysis Conference, Orlando, FL, USA.
10 Azzara, R.M., De Roeck, G., Girardi, M., Padovani, C., Pellegrini, D. and Reynders, E. (2018), "The influence of environmental parameters on the dynamic behaviour of the San Frediano bell tower in Lucca", Eng. Struct., 156, 175-187. https://doi.org/10.1016/j.engstruct.2017.10.045   DOI
11 Bellino, A., Fasana, A., Garibaldi, L. and Marchesiello, S. (2010), "PCA-based detection of damage in time-varying systems", Mech. Syst. Signal Process., 24(7), 2250-2260. https://doi.org/10.1016/j.ymssp.2010.04.009   DOI
12 Binda, L., Gatti, G., Mangano, G., Poggi, C. and Sacchi Landriani, G. (1992), "The collapse of the Civic Tower of Pavia: a survey of the materials and structure", Masonry Int., 20(6), 11-20.
13 Montgomery, D.C. (1997), Introduction to Statistical Quality Control, John Wiley & Sons, New York, NY, USA.
14 Binda, L., Tongini Folli, R. and Mirabella Roberti, G. (2000), "Survey and investigations for the diagnosis of damage in masonry structures: the "Torrazzo" of Cremona", Proceedings of the 12th International Brick/Block Masonry Conference, Madrid, Spain, June.
15 Brincker, R., Zhang, L. and Andersen, P. (2001), "Modal identification of output-only systems using frequency domain decomposition", Smart Mater. Struct., 10(3), 441-445. https://doi.org/10.1088/0964-1726/10/3/303   DOI
16 Cabboi, A., Gentile, C. and Saisi, A. (2017), "From continuous vibration monitoring to FEM-based damage assessment: application on a stone-masonry tower", Constr. Build. Mater., 156, 252-265. https://doi.org/10.1016/j.conbuildmat.2017.08.160   DOI
17 Cantieni, R. (2014), "One-year monitoring of a historic bell tower", Proceedings of the 9th International Conference on Structural Dynamics, EURODYN 2014, Porto, Portugal, January.
18 Diaferio, M., Foti, D. and Sepe, V. (2007), "Dynamic identification of the tower of the Provincial Administration Building, Bari, Italy", Proceedings of the 11th International Conference on Civil, Structural and Environmental Engineering Computing, Malta, September.
19 Milani, G. and Clementi, F. (2019), "Advanced seismic assessment of four masonry bell towers in Italy after operation modal analysis (OMA) identification", Int. J. Arch. Herit., [In press] https://doi.org/10.1080/15583058.2019.1697768   DOI
20 ISMES (1990), "Indagine conoscitiva e monitoraggio delle strutture murarie e del terreno di fondazione della torre degli Zuccaro (MN)", Technical Report. [In Italian]
21 Gentile, C. and Saisi, A. (2007), "Ambient vibration testing of historic masonry towers for structural identification and damage assessment", Constr. Build. Mater., 21(6), 1311-1321. https://doi.org/10.1016/j.conbuildmat.2006.01.007   DOI
22 Venanzi, I., Kita, A., Cavalagli, N., Ierimonti, L. and Ubertini, F. (2020), "Earthquake-induced damage localization in an historic masonry tower through long-term dynamic monitoring and FE model calibration", Bull. Earthq. Eng., 18(5), 2247-2274. https://doi.org/10.1007/s10518-019-00780-4   DOI
23 Diaferio, M., Foti, D. and Potenza, F. (2018), "Prediction of the fundamental frequencies and modal shapes of historic masonry towers by empirical equations based on experimental data", Eng. Struct., 156, 433-442. https://doi.org/10.1016/j.engstruct.2017.11.061   DOI
24 Doebling, S.W., Farrar, C.R. and Prime, M.B. (1998), "A summary eview of vibration-based damage identification methods", Shock Vib. Digest, 30(2), 91-105.   DOI
25 Masciotta, M.-G., Roque, J.C.A., Ramos, L.F., Lourenco, P.B. (2016), "A multidisciplinary approach to assess the health state of heritage structures: the case study of the Church of Monastery of Jeronimos in Lisbon", Constr. Build. Mater., 116, 169-187. https://doi.org/10.1016/j.conbuildmat.2016.04.146   DOI
26 Kim, J.T. and Stubbs, N. (2003), "Crack detection in beam-type structures using frequency data", J. Sound Vib., 259(1), 145-160. https://doi.org/10.1006/jsvi.2002.5132   DOI
27 Bartoli, G., Betti, M. and Vignoli, A. (2016), "A numerical study on seismic risk assessment of historic masonry towers: a case study in San Gimignano", Bull. Earthq. Eng., 14(6), 1475-1518. https://doi.org/10.1007/s10518-016-9892-9   DOI
28 Kita, A., Cavalagli, N. and Ubertini, F. (2019), "Temperature effects on static and dynamic behavior of Consoli Palace in Gubbio, Italy", Mech. Syst. Signal Process., 120, 180-202. https://doi.org/10.1016/j.ymssp.2018.10.021   DOI
29 Lionello, A., Cavaggioni, I., Modena, C., Casarin, F., Rossi, P.P. and Rossi, C. (2004), "Experimental and numerical analysis of the structural behaviour of St. Stefano's bell-tower in Venice", Proceedings of the 4th International Seminar on Structural Analysis of Historic Constructions, Padova, Italy, November.
30 Lorenzoni, F., Casarin, F., Modena, C., Caldon, M., Islami, K. and da Porto, F. (2013), "Structural health monitoring of the Roman Arena of Verona, Italy", J. Civil Struct. Health Monitor., 3(4), 227-246. https://doi.org/10.1007/s13349-013-0065-0   DOI
31 Gentile, C., Ruccolo, A. and Canali, F. (2019a), "Long-term monitoring for the condition-based structural maintenance of the Milan Cathedral", Constr. Build. Mater., 228, 117101. https://doi.org/10.1016/j.conbuildmat.2019.117101   DOI
32 Douglas, B.M. and Reid, W.H. (1982), "Dynamic tests and system identification of bridges", J. Struct. Div. ASCE, 108(10), 2295- 2312.   DOI
33 Elyamani, A., Caselles, O., Roca, P. and Clapes, J. (2017), "Dynamic investigation of a large historical cathedral", Struct. Control Health Monitor., 24(3), e1885. https://doi.org/10.1002/stc.1885   DOI
34 Gentile, C., Guidobaldi, M. and Saisi, A. (2016), "One-year dynamic monitoring of a historic tower: damage detection under changing environment", Meccanica, 51(11), 2873-2889. https://doi.org/10.1007/s11012-016-0482-3   DOI
35 Gentile, C., Saisi, A. and Borlenghi, P. (2019b), "FE modelling for seismic assessment of an ancient tower from ambient vibration survey", Proceedings of the 8th IOMAC - International Operational Modal Analysis Conference, Copenhagen, Denmark, May.
36 Hotelling, H. (1947), "Multivariate quality control-illustrated by the air testing of sample bombsights", in Eisenhart C. et al. (ed.) In: Techniques of Statistical Analysis, pp. 111-184.
37 Jolliffe, I.T. (2002), Principal Component Analysis, Springer, New York, NY, USA.
38 Kennedy, J. and Eberhart, R. (1995), "Particle Swarm Optimization", Proceedings of IEEE International Conference on Neural Networks, Perth, Australia, November.
39 Messina, A., Williams, E.J. and Contursi, T. (1998), "Structural damage detection by a sensitivity and statistical-based method", J. Sound Vib., 216(5), 791-808. https://doi.org/10.1006/jsvi.1998.1728   DOI
40 Pena, F., Lourenco, P.B., Mendes, N. and Oliveira, D.V. (2010), "Numerical models for the seismic assessment of an old masonry tower", Eng. Struct., 32(5), 1466-1478. https://doi.org/10.1016/j.engstruct.2010.01.027   DOI
41 Potenza, F., Federici, F., Lepidi, M., Gattulli, V., Graziosi, F. and Colarieti, A. (2015), "Long-term structural monitoring of the damaged Basilica S. Maria di Collemaggio through a low-cost wireless sensor network", J. Civil Struct. Health Monitor., 5(5), 655-676. https://doi.org/10.1007/s13349-015-0146-3   DOI
42 Ramos, L.F., Aguilar, R., Lourenco, P.B. and Moreira, S. (2013), "Dynamic structural health monitoring of Saint Torcato church", Mech. Syst. Signal Process., 35(1-2), 1-15. https://doi.org/10.1016/j.ymssp.2012.09.007   DOI