Browse > Article
http://dx.doi.org/10.12989/sss.2020.25.3.279

Study on magnetorheological damper stiffness shift  

Jafarkarimi, Mohammad H. (Department of Mechanical Engineering, Tarbiat Modares University)
Ghorbanirezaei, Shahryar (Department of Mechanical Engineering, Tarbiat Modares University)
Hojjat, Yousef (Department of Mechanical Engineering, Tarbiat Modares University)
Sabermand, Vahid (Department of Mechanical Engineering, Tarbiat Modares University)
Publication Information
Smart Structures and Systems / v.25, no.3, 2020 , pp. 279-284 More about this Journal
Abstract
Electrical current is usually used to change the damping force of Magnetorheological Dampers (MRDs). However, changing the electrical current could shift the stiffness of the system, the phenomenon that was not considered carefully. This study aims to evaluate this shift. A typical MRD was designed, optimized, and fabricated to do some accurate and detailed experimental tests to examine the stiffness variation. The damper is equipped with a circulating system to prevent the deposition of particles when it is at rest. Besides that, a vibration setup was developed for the experimental study. It is capable of generating vibration with either constant frequency or frequency sweep and measure the amplitude of vibration. The damper was tested by the vibrating setup, and it was concluded that with a change in electrical current from 0 to 1.4 A, resonant frequency would change from 13.8 Hz to 16 Hz. Considering the unchanging mass of 85.1 kg, the change in resonant frequency translates as a shift in stiffness, which changes from 640 kN/m to 860 kN/m.
Keywords
magnetorheological damper; stiffness shift; magnetorheological fluid; magnetorheological valve;
Citations & Related Records
Times Cited By KSCI : 4  (Citation Analysis)
연도 인용수 순위
1 Askari, M., Li, J. and Samali, B. (2016), "Semi-active control of smart building-MR damper systems using novel TSK-Inv and max-min algorithms", Smart Struct. Syst., Int. J., 18(5), 1005-1028. https://doi.org/10.12989/sss.2016.18.5.1005   DOI
2 Behrooz, M., Wang, X. and Gordaninejad, F. (2014), "Modeling of a new semi-active/passive magnetorheological elastomer isolator", Smart Mater. Struct., 23(4), 045013. https://doi.org/10.1088/0964-1726/23/4/045013   DOI
3 Deng, H.X., Gong, X.L. and Wang, L.H. (2006), "Development of an adaptive tuned vibration absorber with magnetorheological elastomer", Smart Mater. Struct., 15(5), 111-116. https://doi.org/10.1088/0964-1726/15/5/N02
4 Jugulkar, L.M., Singh, S. and Sawant, S.M. (2016), "Analysis of suspension with variable stiffness and variable damping force for automotive applications", Adv. Mech. Eng., 8(5), 1-19. https://doi.org/10.1177%2F1687814016648638
5 Li, W., Wang, X.Y., Zhang, X.Z. and Zhou, Y. (2009), "Development and analysis of a variable stiffness damper using an MR bladder", Smart Mater. Struct., 18(7), 074007. https://doi.org/10.1088/0964-1726/18/7/074007   DOI
6 Liu, Y., Matsuhisa, H., Utsuno, H. and Park, J.G. (2006), "Vibration control by a variable damping and stiffness system with magnetorheological dampers", JSME Int. J. Series C Mech. Syst. Mach. Eleme. Manuf., 49(2), 411-417. https://doi.org/10.1299/jsmec.49.411
7 Maddah, A.A., Hojjat, Y., Karafi, M.R. and Ashory, M.R. (2017), "Reduction of magneto rheological damper stiffness by incorporating of an eddy current damper", J. Sound Vib., 396, 51-68. https://doi.org/10.1016/j.jsv.2017.02.011   DOI
8 Sun, S., Yang, J., Li, W., Deng, H., Du, H. and Alici, G. (2015), "Development of a novel variable stiffness and damping magnetorheological fluid damper", Smart Mater. Struct., 24(8), 085021-1-085021-10. https://doi.org/10.1088/0964-1726/24/8/085021   DOI
9 Sun, C., Nagarajaiah, S. and Dick, A.J. (2014a), "Family of smart tuned mass dampers with 2 variable frequency under harmonic excitations and ground motions: Closed-form evaluation", Smart Struct. Syst., Int. J., 13(2), 319-341. https://doi.org/10.12989/sss.2014.13.2.319   DOI
10 Sun, S., Deng, H. and Li, W. (2014b), "A variable stiffness and damping suspension system for trains", Proceedings of SPIE: Active and Passive Smart Structures and Integrated Systems, 9057, 1-9. https://doi.org/10.1117/12.2045023
11 Sun, S., Tang, X., Li, W. and Du, H. (2017), "Advanced vehicle suspension with variable stiffness and damping MR damper", Proceedings of 2017 IEEE International Conference on Mechatronics (ICM), Churchill, Australia. https://doi.org/10.1109/ICMECH.2017.7921148
12 Zhu, X., Deng, L., Sun, S., Yan, T., Yu, J., Ma, Z. and Li, W. (2019), "Development of a variable stiffness magnetorheological damper with self-powered generation capability", J. Intel. Mater. Syst. Struct., 31(2), 209-219. https://doi.org/10.1177/1045389x19862640   DOI
13 Wang, X., Pereira, E., Diaz, I.M. and Garcia-Palacios, J.H. (2018), "Velocity feedback for controlling vertical vibrations of pedestrian-bridge crossing. Practical guidelines", Smart Struct. Syst., Int. J., 22(1), 95-103. https://doi.org/10.12989/sss.2018.22.1.095
14 Weber, F., Boston, C. and Maslanka, M. (2010), "An adaptive tuned mass damper based on the emulation of positive and negative stiffness with an MRD", Smart Mater. Struct., 20, 015012. https://doi.org/10.1088/0964-1726/20/1/015012   DOI