Design and calibration of a semi-active control logic to mitigate structural vibrations in wind turbines  

Caterino, Nicola (Department of Civil Engineering, University of Naples "Parthenope")
Georgakis, Christos T. (Department of Civil Engineering, Technical University of Denmark (DTU))
Spizzuoco, Mariacristina (Department of Structures for Engineering and Architecture, University of Naples Federico II)
Occhiuzzi, Antonio (Department of Civil Engineering, University of Naples "Parthenope")
Publication Information
Smart Structures and Systems / v.18, no.1, 2016 , pp. 75-92 More about this Journal
Abstract
The design of a semi-active (SA) control system addressed to mitigate wind induced structural demand to high wind turbine towers is discussed herein. Actually, the remarkable growth in height of wind turbines in the last decades, for a higher production of electricity, makes this issue pressing than ever. The main objective is limiting bending moment demand by relaxing the base restraint, without increasing the top displacement, so reducing the incidence of harmful "p-delta" effects. A variable restraint at the base, able to modify in real time its mechanical properties according to the instantaneous response of the tower, is proposed. It is made of a smooth hinge with additional elastic stiffness and variable damping respectively given by springs and SA magnetorheological (MR) dampers installed in parallel. The idea has been physically realized at the Denmark Technical University where a 1/20 scale model of a real, one hundred meters tall wind turbine has been assumed as case study for shaking table tests. A special control algorithm has been purposely designed to drive MR dampers. Starting from the results of preliminary laboratory tests, a finite element model of such structure has been calibrated so as to develop several numerical simulations addressed to calibrate the controller, i.e., to achieve as much as possible different, even conflicting, structural goals. The results are definitely encouraging, since the best configuration of the controller leaded to about 80% of reduction of base stress, as well as to about 30% of reduction of top displacement in respect to the fixed base case.
Keywords
semi-active control; wind turbine; magnetorheological damper; control algorithm;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 Basu, B., Staino, A. and Basu, M. (2014), "Role of flexible alternating current transmission systems devices in mitigating grid fault-induced vibration of wind turbines", Wind Energy, 17, 1017-1033.   DOI
2 Bortoluzzi, D., Casciati, S., Elia, L. and Faravelli, L. (2015), "Design of a TMD solution to mitigate wind-induced local vibrations in an existing timber footbridge", Smart Struct. Syst., 16(3), 459-478, doi: 10.12989/sss.2015.16.3.459.   DOI
3 Caterino, N. (2015), "Semi-active control of a wind turbine via magnetorheological dampers", J. Sound Vib., 345, 1-17, doi:10.1016/j.jsv.2015.01.022.   DOI
4 Caterino, N., Georgakis, C.T., Trinchillo, F. and Occhiuzzi, A. (2014), "A semi-active control system for wind turbines", In: N. Luo, Y. Vidal, L. Acho, Wind Turbine Control and Monitoring, Springer International Publishing, 375-407, Advances in Industrial Control, doi: 10.1007/978-3-319-08413-8_13.   DOI
5 Caterino, N., Spizzuoco, M. and Occhiuzzi, A. (2011), "Understanding and modelling the physical behaviour of magnetorheological dampers for seismic structural control", Smart Mater. Struct., 20(6), doi:10.1088/0964-1726/20/6/065013.   DOI
6 Caterino, N., Spizzuoco, M. and Occhiuzzi, A. (2013), "Promptness and dissipative capacity of MR dampers: experimental investigations", Struct. Control Health Monit., 20(12), 1424-1440, doi: 10.1002/stc.1578.   DOI
7 Chen, J. and Georgakis, C.T. (2013), "Tuned rolling-ball dampers for vibration control in wind turbines", J. Sound Vib., 332, 5271-5282, dx.doi.org/10.1016/j.jsv.2013.05.019.   DOI
8 Chen, J. and Georgakis, C.T. (2015), "Spherical tuned liquid damper for vibration control in wind turbines", J. Vib. Control, 21(10), 1875-1885, doi: 10.1177/1077546313495911.   DOI
9 Colwell, S. and Basu, B. (2009), "Tuned liquid column dampers in offshore wind turbines for structural control", Eng. Struct., 31, 358-368, doi: 10.1016/j.engstruct.2008.09.001.   DOI
10 Dinh, V.N. and Basu, B. (2015), "Passive control of floating offshore wind turbine nacelle and spar vibrations by multiple tuned mass dampers", Struct. Control Health Monit., 22(1), 152-176.   DOI
11 Lackner, M. and Rotea, M. (2011), "Structural control of floating wind turbines", Mechatronics, 21, 704-719, doi:10.1016/j.mechatronics.2010.11.007.   DOI
12 Enevoldsen, I. and Mork, K. (1996), "Effects of a vibration mass damper in a wind turbine tower", Mech. Struct. Mach., 24, 155-187.   DOI
13 Karimi, H.R., Zapateiro, M. and Luo, N. (2010), "Semiactive vibration control of offshore wind turbine towers with tuned liquid column dampers using $H{\infty}$ output feedback control", Proceedings of the IEEE International Conference on Control Applications, Yokohama, Japan.
14 Kirkegaard, P.H., Nielsen, S.R.K., Poulsen, B.L., Andersen, J., Pedersen, L.H. and Pedersen, B.J. (2002), Semi-active vibration control of a wind turbine tower using an MR damper, H. Grundmann, G.I. Schueller, Rotterdam: Balkema Publishers, A.A. / Taylor & Francis The Netherlands, 1575-1580.
15 Larsen, T.J. and Hansen, A.M. (2008), HAWC2 User Manual, Roskilde, Denmark: Riso National Laboratory, Technical University of Denmark.
16 Li, J., Zhang, Z. and Chen, J. (2012), "Experimental study on vibration control of offshore wind turbines using a ball vibration absorber", Energy Power Eng., 4, 153-157, doi: 10.4236/epe.2012.43021.   DOI
17 Luo, N., Bottasso, C.L., Karimi, H.R. and Zapateiro, M. (2011), "Semiactive Control for floating offshore wind turbines subject to aero-hydro dynamic loads", Proceedings of the International Conference on Renewable Energies and Power Quality, Las Palmas de Gran Canaria, Spain.
18 Murtagh, P.J., Ghosh, A., Basu, B. and Broderick, B.M. (2008), "Passive control of wind turbine vibrations including blade/tower interaction and rotationally sampled turbulence", Wind Energy, 11, 305-317, doi: 10.1002/we.249.   DOI
19 Rodriguez, T.A., Carcangiu, C.E., Pineda, I., Fischer, T., Kuhnle, B., Scheu, M. and Martin, M. (2011), "Wind turbine structural damping control for tower load reduction", Proceedings of the 29th IMAC, A Conference and Exposition on Structural Dynamics, Jacksonville, FL, USA.
20 Pedersen, A.S. (2012), "Safe operation and emergency shutdown of wind turbines", Master Thesis in 'Intelligent Autonomous Systems', Department of Electronic Systems, Aalborg University.
21 Salvi, J. and Rizzi, E. (2016), "Closed-form optimum tuning formulas for passive Tuned Mass Dampers under benchmark excitations", Smart Struct. Syst., 17(2), 231-256, doi: 10.12989/sss.2016.17.2.231.   DOI
22 Wisniewsky, R., Svenstrup, M., Pedersen, A.S. and Steiniche C.S. (2013), "Certificate for safe emergency shutdown of wind turbines", Proceedings of the American Control Conference (ACC), 3667-3672, Washington, DC.
23 Zhang, Z.L., Chen, J.B. and Li, J. (2013), "Theoretical study and experimental verification of vibration control of offshore wind turbines by a ball vibration absorber", Struct. Infrastruct. Eng., 5, doi.org/10.1080/15732479.2013.792098.