Abstract
The Jiangyin Bridge is a suspension bridge with a main span of 1385 m over the Yangtze River in Jiangsu Province, China. Being the first bridge with a main span exceeding 1 km in Chinese mainland, it had been instrumented with a structural health monitoring (SHM) system when completed in 1999. After operation for several years, it was found with malfunction in sensors and data acquisition units, and insufficient sensors to provide necessary information for structural health evaluation. This study reports the SHM system upgrade project on the Jiangyin Bridge. Although implementations of SHM system have been reported worldwide, few studies are available on the upgrade of SHM system so far. Recognizing this, the upgrade of original SHM system for the bridge is first discussed in detail. Especially, lessons learned from the original SHM system are applied to the design of upgraded SHM system right away. Then, performance assessment of the bridge, including: (i) characterization of temperature profiles and effects; (ii) recognition of wind characteristics and effects; and (iii) identification of modal properties, is carried out by making use of the long-term monitoring data obtained from the upgraded SHM system. Emphasis is placed on the verification of design assumptions and prediction of bridge behavior or extreme responses. The results may provide the baseline for structural health evaluation.
Keywords
structural health monitoring; performance assessment; environmental effect; system upgrade; long-span bridge;
Citations & Related Records
Times Cited By KSCI : 4  (Citation Analysis)
연도 인용수 순위
1 Feng, M.Q. (2009), "Application of structural health monitoring in civil infrastructure", Smart Struct. Syst., 5(4), 469-482.   DOI   ScienceOn
2 Fujino, Y. and Siringoringo, D.M. (2011), "Bridge monitoring in Japan: the needs and strategies", Struct. Infrastruct. E., 7(7-8), 597-611.   DOI   ScienceOn
3 Ni, Y.Q., Hua, X.G., Wong, K.Y. and Ko, J.M. (2007a), "Assessment of bridge expansion joints using long-term displacement and temperature measurement", J. Perform. Constr. Fac.,21(2), 122-135.
4 Ni, Y.Q., Ko, J.M., Hua, X.G. and Zhou, H.F. (2007b), "Variability of measured modal frequencies of a cable-stayed bridge under different wind conditions", Smart Struct. Syst., 3(3), 341-356.   DOI   ScienceOn
5 Ni, Y.Q., Zhou, H.F. and Ko, J.M. (2009), "Generalization capability of neural network models for temperature-frequency correlation using monitoring data", J. Struct. Eng. - ASCE, 135(10), 1290-1300.   DOI   ScienceOn
6 Andersen, E.Y. and Pedersen, L. (1994), Structural monitoring of the Great Belt East Bridge, Strait Crossings 94, (Ed. Krokebogr, J.), Rotterdam: Balkema, 189-195.
7 Barrish, R.A. Jr., Grimmelsman, K.A. and Aktan, A.E. (2000), Instrumented monitoring of the Commodore Barry Bridge, Nondestructive Evaluation of Highways, Utilities, and Pipelines IV, (Eds., Aktan, A.E. and Gosselin, S.R. ), Bellingham: SPIE, 112-126.
8 Brownjohn, J.M.W. (2007), "Structural health monitoring of civil infrastructure", Philos. T. R. Soc. A., 365(1851), 589-622.   DOI   ScienceOn
9 Zhou, H.F., Ni, Y.Q. and Ko, J.M. (2007), "A data processing and analysis system for the instrumented suspension Jiangyin Bridge", Proceedings of the World Forum on Smart Materials and Smart Structures Technology, (Eds., Spencer, B.F. Jr., Tomizuka, M., Yun, C.B., Chen, W.M. and Chen, R.W.), London: Taylor & Francis, CD-ROM.
10 Yun, C.B., Lee, J.J. and Koo, K.Y. (2011), "Smart structure technologies for civil infrastructures in Korea: recent research and applications", Struct. Infrastruct. E., 7(9), 673-688.   DOI   ScienceOn
11 Zhou, H.F., Ni, Y.Q., Ko, J.M. and Wong, K.Y. (2008), "Modeling of wind and temperature effects on modal frequencies and analysis of relative strength of effect", Wind Struct., 11(1), 35-50.   DOI   ScienceOn
12 Zhou, H.F., Ni, Y.Q. and Ko, J.M. (2010), "Constructing input to neural networks for modeling temperature-caused modal variability: mean temperatures, effective temperatures, and principal components of temperatures", Eng. Struct., 32(6), 1747-1759.   DOI   ScienceOn
13 Zhou, H.F., Ni, Y.Q. and Ko, J.M. (2011a), "Structural damage alarming using auto-associative neural network technique: Exploration of environment-tolerant capacity and setup of alarming threshold", Mech. Syst. Signal Pr., 25(5), 1508-1526.   DOI   ScienceOn
14 Maes, M.A., Dilger, W.H. and Ballyk, P.D. (1992), "Extreme values of thermal loading parameters in concrete bridges", Can. J. Civil Eng., 19(6), 935-946.   DOI
15 Zhou, H.F., Ni, Y.Q. and Ko, J.M. (2011b), "Eliminating temperature effect in vibration-based structural damage detection", J. Eng. Mech. - ASCE, 137(12), 785-796.   DOI   ScienceOn
16 Kim, S., Chang, S.P. and Lee, J. (2002), "Autonomous on-line health monitoring system for a cable-stayed bridge", Proceedings of the 1st European Workshop on Structural Health Monitoring, (Ed. Balageas, D.L. ), Lancaster: Destech, 1254-1261.
17 Lau, C.K., Mak, W.P.N., Wong, K.Y., Chan, W.Y.K. and Man, K.L.D. (1999), Structural health monitoring of three cable-supported bridges in Hong Kong, Structural Health Monitoring, (Ed. Chang, F.K.), Lancaster: Destech, 450-460.
18 Ministry of Transport of the People's Republic of China (2004), Wind-resistant Design Specification for Highway Bridges, China Communication Press, Beijing.
19 Ou, J.P. and Li, H. (2010), "Structural health monitoring in mainland China: review and future trends", Struct. Health Monit., 9(3), 219-231.   DOI   ScienceOn
20 Shi, J.J., Zhang, Q.W. and Xiang, H.F. (2000), "Health monitoring system of Xupu cable-stayed bridge", Proceedings of the International Workshop on Response and Monitoring of Long Span Bridge, Hong Kong.
21 Wong, K.Y. and Ni, Y.Q. (2009), Structural health monitoring of cable-supported bridges in Hong Kong, Chapter 12 of the book: Structural Health Monitoring of Civil Infrastructure Systems, (Eds.,V.M. Karbhari and F. Ansari), Woodhead Publishing, Cambridge, UK, 371-411.
22 Simiu, E. and Scanlan, R.H. (1996), Wind effects on structures, 3rd Ed, John Wiley & Sons, New York.
23 Sohn, H., Farrar, C.R., Hemez, F.M., Shunk, D.D., Stinemates, D.W., Nadler, B.R. and Czarnecki, J.J. (2004), A review of structural health monitoring literature: 1996-2001, Report No. LA-13976-MS, Los Alamos National Laboratory, Los Alamos, New Mexico, USA.
24 Sumitro, S., Matsui, Y., Kono, M., Okamoto, T. and Fujii, K. (2001), Long span bridge health monitoring system in Japan, Health Monitoring and Management of Civil Infrastructure Systems, (Eds., Chase, S.B. and Aktan, A.E. ), Bellingham: SPIE, 517-524.
25 Cheung, M.S., Tadros, G.S., Brown, T., Dilger, W.H., Ghali, A. and Lau, D.T. (1997), "Field monitoring and research on performance of the Confederation Bridge", Can. J. Civil Eng., 24(6), 951-962.
26 Choi, C.C. (1983), Wind loading in Hong Kong - commentary on the code of practice on wind effects Hong Kong-1983, Hong Kong Institution of Engineers, Hong Kong.
27 Ciambella, J., Vestroni, F. and Vidoli, S. (2011), "Damage observability, localization and assessment based on eigenfrequencies and eigenvectors curvatures", Smart Struct. Syst., 8(2), 191-204.   DOI   ScienceOn
28 Cook, N.J. (1985), The designer's guide to wind loading of building structures, Butterworth-Heinemann, UK.
29 Doebling, S.W., Farrar, C.R. and Prime, M.B. (1998), "A summary review of vibration-based damage identification methods", Shock Vib., 30(2), 91-105.   DOI   ScienceOn