Browse > Article
http://dx.doi.org/10.12989/scs.2022.43.4.431

Axial compression behavior of double-skinned composite tubular columns under pure compression on concrete cores  

Lee, Jeonghwa (Futhre and Fusion Lab of Architectural Civil and Environmental Engineering, Korea University)
Byun, Namju (Futhre and Fusion Lab of Architectural Civil and Environmental Engineering, Korea University)
Kang, Young Jong (School of Civil, Environmental and Architectural Engineering, Korea University)
Won, Deok Hee (Department of Civil Engineering, Halla University)
Kim, Seungjun (School of Civil, Environmental and Architectural Engineering, Korea University)
Publication Information
Steel and Composite Structures / v.43, no.4, 2022 , pp. 431-445 More about this Journal
Abstract
A double-skinned composite tubular (DSCT) column, which is an internally confined concrete-filled tubular column with a hollow section, has been developed for efficient use of materials that reduce self-weight and enhance seismic performance. It exhibits excellent material behavior with ductility owing to the confinement induced by outer and inner steel tubes. This study conducted axial compression tests considering the effects of steel tube thickness and hollow diameter ratios of DSCT columns on the material behavior of confined concrete under pure axial compression on concrete cores. From the axial compression tests, various combinations of outer and inner tube thicknesses and two different hollow section ratios were considered. Additionally, confined concrete material behavior, axial strength, failure modes, and ductility of DSCT columns were evaluated. Based on this study, it was concluded that the tests show a good correlation with peak strength and shapes of nonlinear stress-strain curves presented in literature; however, the thinner outer and inner steel tubes may reduce the ductility of DSCT columns when using thinner outer and inner tubes and higher confined stress levels. Finally, the minimum thickness requirements of the steel tubes for DSCT columns were discussed in terms of strength and ductility of test specimens.
Keywords
DSCT column; confined concrete; axial compression tests; stress-strain relationship; ductility;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Han, T.H., Han, K.H., Han, S.Y., Kim, S.N., Kang, J.O. and Kang, Y.J. (2005). "The behavior of an internally confined hollow concrete filled steel tube column", Proceeding of the 8th KoreaJapan joint semina.
2 Han, T.H., Kim, S., Won, D.H. and Kang, Y.J. (2013), "Performance of a double-skinned composite tubular column under lateral loading: Analysis", Mag. Concrete Res., 65(2), 121-135. https://doi.org/10.1680/macr.12.00024.   DOI
3 KCI (2012), Korean Concrete Structure Standard, Ministry of Land, Transport and Maritime Affairs
4 Liang, Q.Q. (2018), "Numerical simulation of high strength circular double-skin concrete-filled steel tubular slender columns", Eng. Struct., 168, 205-217. https://doi.org/10.1016/j.engstruct.2018.04.062.   DOI
5 Popovics, S. (1973), "A numerical approach to the complete stress-strain curves of concrete", Cement Concrete Res., 3(5), 583-599. https://doi.org/10.1016/0008-8846(73)90096-3.   DOI
6 Wei, S., Mau, M.T., Vipulanandan, C. and Mantrala, S.K. (1995), "Performance of new sandwich tube under axial loading: experiment", J. Struct. Eng., 121(12), 1806-1814. https://doi.org/10.1061/(ASCE)0733-9445(1995)121:12(1806).   DOI
7 Zhao, X.L. and Grzebieta, R. (2002), "Strength and ductility of concrete filled double skin (SHS inner and SHS outer) tubes", Thin-Wall. Struct., 40 199-213. https://doi.org/10.1016/S0263-8231(01)00060-X.   DOI
8 Hu, H.T. and Su, F.C. (2011), "Nonlinear analysis of short concrete-filled double skin tube columns subjeced to axial compressive forces", Marine Struct., 24(4), 319-337. https://doi.org/10.1016/j.marstruc.2011.05.001.   DOI
9 ANSI/AISC (2016), ANSI/AISC 360-16 Specification for Structural Steel Buildings, American Istitute of Steel Construction, USA.
10 Han, T.H., Stallings, J.M. and Kang, Y.J. (2010), "Nonlinear concrete model for double-skinned composite tubular columns", Construct. Build. Mater., 24 2542-2553. https://doi.org/10.1016/j.conbuildmat.2010.06.001.   DOI
11 Kerr, A.D. and Soifer, M.T. (1996), "The linearization of the prebuckling state and its effects on the determined instability load", J. Appl. Mech.. 36(4), 775-785. https://doi.org/10.1115/1.3564770.   DOI
12 Liang, Q.Q. (2016), "Nonlinear analysis of circular double-skin concrete-flled steel tubular columns under axial compression", Eng. Struct., 131 639-650. https://doi.org/10.1016/j.engstruct.2016.10.019.   DOI
13 Won, D.H., Han, T.H., Kim, S., Lee, J.H. and Kang, Y.J. (2014), "Confining effect of concrete in double-skinned composite tubular columns", Computers Concrete. 14(5), 613-633. https://doi.org/10.12989/cac.2014.14.5.613.   DOI
14 Mander, J.B., Priestley, M.J.N. and Park, R. (1988), "heoretical stress-strain model for confined concrete", J. Struct. Eng., 114(8), 1804-1826. https://doi.org/10.1061/(ASCE)0733-9445(1988)114:8(1804).   DOI
15 Pagoulatou, M., Sheehan, T., Dai, X.H. and Lam, D. (2014), "Finite element analysis on the capacity of circular concretefilled double-skin steel tubular (CFDST) stub colums", Eng. Struct., 72, 102-112. https://doi.org/10.1016/j.engstruct.2014.04.039.   DOI
16 Shakir-Khalil, H. and Illoul, S. (1987), "Composite columns of concentric steel tubes", Proceeding of Conference on the Design and Construction of Non Conventional Structures.
17 Tao, Z., Han, L.H. and Zhao, X.L. (2004), "Behavior of concretefilled double skn (CHS inner and CHS outer) steel tubular stub columns and beam columns", J. Construct. Steel Res., 60 1129-1158. https://doi.org/10.1016/j.jcsr.2003.11.008.   DOI
18 Wei, S., Mau, S.T., Vipulanandan, C. and Mantrala, S.K. (1995), "Performance of new sandwich tube under axial loading: Analysis", J. Struct. Eng., 121(12), 1815-1821. https://doi.org/10.1061/(ASCE)0733-9445(1995)121:12(1815).   DOI