Browse > Article
http://dx.doi.org/10.12989/scs.2021.41.4.533

Introducing new rigid I-beam to box column connections by using a stiffened channel link  

Garoosi, Allah Reza Moradi (Department of Civil Engineering, Sanandaj Branch, Islamic Azad University)
Roudsari, Mehrzad Tahamouli (Department of Civil Engineering, Kermanshah Branch, Islamic Azad University)
Torkaman, Morteza (Department of Civil Engineering, Kermanshah Branch, Islamic Azad University)
Bonyadirad, Shahab (Department of Civil Engineering, Kermanshah Branch, Islamic Azad University)
Saeedmanesh, Ali (Department of Civil Engineering, Kermanshah Branch, Islamic Azad University)
soleimani, Khalil (Department of Civil Engineering, Kermanshah Branch, Islamic Azad University)
Lotfi, Hosein Reza (Department of Civil Engineering, Kermanshah Branch, Islamic Azad University)
Jowkar, Roya (Department of Civil Engineering, Kermanshah Branch, Islamic Azad University)
Alipour, Ali (Department of Civil Engineering, Kermanshah Branch, Islamic Azad University)
Publication Information
Steel and Composite Structures / v.41, no.4, 2021 , pp. 533-548 More about this Journal
Abstract
The aim of this study is to present a new and suitable connection for I-shaped beams and box columns that is both constructionally convenient to implement and reliable in terms of its performance. Six full-scale experimental samples were constructed and subjected to cyclic Quasi-static loading. The first sample included an I-shaped beam which was directly connected to a box column, the second sample incorporated a channel link, and stiffened channel links were used in the remaining four samples. The results show that compared to the direct connection, using the stiffened channel link significantly improves the performance of the connection and increases its ultimate strength and ductility by 58% and 70%, respectively. Also, these connections satisfy the code-specified criteria for special moment resisting frames. They are therefore a suitable detail for rigid I-shaped-beam-to-box-column connections in seismically active regions.
Keywords
cyclic loading; full-scale test; rigid I-shaped beam-to-box column connection; special steel moment resisting frame; stiffened channel link;
Citations & Related Records
Times Cited By KSCI : 4  (Citation Analysis)
연도 인용수 순위
1 Tahamouli Roudsari, M., Jamshidi, K,H. and Mohebi Zangeneh, M. (2016), "Experimental and numerical investigation of IPE reduced beam sections with diagonal web stiffeners", J. Earthq. Eng., 22(4), 533-552. https://doi.org/10.1080/13632469.2016.1234422.   DOI
2 Tahamouli Roudsari, M., Sohaei, S., Torkaman, M., Safaee, S.A., Tahmasebi, S., Mohammadi, S. and Ghiasvand, M.M. (2020), "Presenting a new detail for the rigid connection between I-shaped beam and concrete-filled steel tube column with stiffened channel link", Int. J. Steel Struct., 20, 655-667. https://doi.org/10.1007/s13296-020-00312-w.   DOI
3 Wang, Y.C. and Xue, L. (2013), "Experimental study of moment-rotation characteristics of reverse channel connections to tubular columns", J. Constr. Steel Res., 85, 92-104. https://doi.org/10.1016/j.jcsr.2013.03.006.   DOI
4 Gholami, M., Deylami, A. and Tehranizadeh, M. (2013), "Seismic performance of flange plate connections between steel beams and box columns", J. Constr. Steel Res., 84, 36-48. https://doi.org/10.1016/j.jcsr.2012.11.011.   DOI
5 Deylami, A., Tehranizadeh, M. and Gholami, M. (2013), "Panel Zone in the Flange Plate Connection to Box Column", Proceedings of the 13th East Asia-Pacific Conference on Structural Engineering and Construction (EASEC-13), The Thirteenth East Asia-Pacific Conference on Structural Engineering and Construction (EASEC-13), Sep 11.
6 Wang, Z.B., Tao, Z., Li, D.S. and Han, L.H. (2016), "Cyclic behaviour of novel blind bolted joints with different stiffening elements", Thin-Wall. Struct., 101, 157-168. https://doi.org/10.1016/j.tws.2016.01.007.   DOI
7 ISO 898-1 (2009), mechanical properties of fasteners made of carbon steel and alloy steel -Part 1: , screws and studs with pacified property classes - coarse thread and fine pitch thread, International Organization for Standardization; Geneva, Switzerland.
8 Tahamouli Roudsari, M., Sohaei, S., Torkaman, M., Alizadeh, A., Safaee, S., Haghaninia, A. and Mohammadi Majd, M. (2019), "Experimental investigation of I-shaped beam to circular column rigid connection with stiffened and non-stiffened channel link", J. Earthq. Eng., 1-23. https://doi.org/10.1080/13632469.2019.1628129.   DOI
9 AISC/ANSI 341-10 (2010), American Institute of Steel Construction, Seismic Provisions for Structural Steel Buildings, Chicago (IL), USA.
10 ANSI/AISC 341-16 (2016), American Institute of Steel Construction, Seismic Provisions for Structural Steel Buildings; Chicago, Illinois, USA.
11 Choi, S.M., Jung, D.S., Kim, D.J. and Kim, J.H. (2007), "An evaluation equation of load capacities for CFT square column-to-beam connections with combined diaphragm", Steel Compos. Struct., 7(4), 303-320. https://doi.org/10.12989/scs.2007.7.4.303.   DOI
12 ANSI/AISC 360-16 (2016), American Institute of Steel Construction, Specification for Structural Steel Buildings; Chicago, Illinois, USA.
13 ASTM Standard A370-02 (2002), Standard test methods and definitions for mechanical testing of steel products, American Society for Testing and Materials; Philadelphia, PA.
14 Chen, C.C., Lin, C.C. and Tsai, C.L. (2004), "Evaluation of reinforced connections between steel beams and box columns", Eng. Struct., 26(13), 1889-1904. https://doi.org/10.1016/j.engstruct.2004.06.017.   DOI
15 Erfani, S., Asnafi, A.A. and Goudarzi, A. (2016), "Connection of I-beam to box-column by a short stub beam", J. Constr. Steel Res., 127, 136-150. https://doi.org/10.1016/j.jcsr.2016.07.025.   DOI
16 FEMA- 440 (2005), Improvement of nonlinear static seismic analysis procedures, Federal Emergency Management Agency; Redwood City.
17 Hadianfard, M.A. and Rahnema, H. (2010), "Effects of RHS face deformation on the rigidity of beam-column connection", Steel Compos. Struct., 10(6), 489-500. https://doi.org/10.12989/scs.2010.10.6.489.   DOI
18 AlHendi, H. and Celikag, M. (2015), "Behavior of reverse-channel and double-reverse-channel connections to tubular columns with HSS", J. Constr. Steel Res., 112, 271-281. https://doi.org/10.1016/j.jcsr.2015.05.017.   DOI
19 ANSI/AISC 358-16 (2016), Prequalified connections for special and intermediate steel moment frames for seismic applications, American Institute of Steel Construction; Chicago, Illinois, USA.
20 Garoosi, A.M., Tahamouli Roudsari, M. and Hashemi, B.H. (2018), "Experimental evaluation of rigid connection with reduced section and replaceable fuse", Structures, 16, 390-404. https://doi.org/10.1016/j.istruc.2018.11.010.   DOI
21 Huang, Z., Jiang, L.Z., Zhou, W.B. and Chen, S. (2016), "Studies on restoring force model of concrete filled steel tubular laced column to composite box-beam connections", Steel Compos. Struct., 22(6), 1217-1238. https://doi.org/10.12989/scs.2016.22.6.1217.   DOI
22 Saffari, H., Hedayat, A.A. and Goharrizi, N.S. (2013), "Suggesting double-web I-shaped columns for omitting continuity plates in a box-shaped column", Steel Compos. Struct., 15(6), 585-603. https://doi.org/10.12989/scs.2013.15.6.585.   DOI
23 Kim, Y.J. and Oh, S.H. (2007), "Effect of the moment transfer efficiency of a beam web on deformation capacity at box column-to-H beam connections", J. Constr. Steel Res., 63(1), 24-36. https://doi.org/10.1016/j.jcsr.2006.02.009.   DOI
24 Lee, S.H., Yang, I.S. and Choi, S.M. (2010), "Structural characteristics of welded built-up square CFT column-to-beam connections with external diaphragms", Steel Compos. Struct., 10(3), 261-279. https://doi.org/10.12989/scs.2010.10.4.281.   DOI
25 Mirghaderi, S.R., Torabian, S. and Keshavarzi, F. (2010), "I-beam to box-column connection by a vertical plate passing through the column", Eng. Struct., 32(8),2034-2048. https://doi.org/10.1016/j.engstruct.2010.03.002.   DOI
26 Naserabad, A.A., Ghasemi, M.R., Shabakhty, N. and Arab, H.G. (2019), "Design of a novel prefabricated bolted I-beam to box-column connection using numerical analysis under cyclic load", Int. J. Steel Struct., 19(5), 1-15. https://doi.org/10.1007/s13296-019-00222-6.   DOI
27 Rezaifar, O., Nazari, M. and Gholhaki, M. (2017), "Experimental study of rigid beam-to-box column connections with types of internal/external stiffeners", Steel Compos. Struct., 25(5), 535-544. https://doi.org/10.12989/scs.2017.25.5.535.   DOI
28 Behrooz, S.M. and Erfani, S. (2020), "Parametric study of Stub-Beam Bolted Extended End-Plate connection to box-columns", J. Constr. Steel Res., 171, 106155. https://doi.org/10.1016/j.jcsr.2020.106155   DOI
29 Chou, C.C. and Jao, C.K. (2010), "Seismic rehabilitation of welded steel beam-to-box column connections utilizing internal flange stiffeners", Earthq. Spectra, 26(4), 927-950. https://doi.org/10.1193/1.3480275.   DOI
30 Esfandyary, R., Razzaghi, M.S., Eslami, A. and Branch, T. (2015), "A parametric investigation on the hysteretic behaviour of CFT column to steel beam connections", Struct. Eng. Mech., 55(1), 205-228. https://doi.org/10.12989/sem.2015.55.1.205.   DOI