Experimental investigation of carbon steel and stainless steel bolted connections at different strain rates  

Cai, Yancheng (Department of Civil Engineering, The University of Hong Kong)
Young, Ben (Department of Civil and Environmental Engineering, The Hong Kong Polytechnic University)
Publication Information
Steel and Composite Structures / v.30, no.6, 2019 , pp. 551-565 More about this Journal
Abstract
A total of 36 carbon steel and stainless steel bolted connections subjected to shear loading at different strain rates was experimentally investigated. The connection specimens were fabricated from carbon steel grades 1.20 mm G500 and 1.90 mm G450, as well as cold-formed stainless steel types EN 1.4301 and EN 1.4162 with nominal thickness 1.50 mm. The connection tests were conducted by displacement control test method. The strain rates of 10 mm/min and 20 mm/min were used. Structural behaviour of the connection specimens tested at different strain rates was investigated in terms of ultimate load, elongation corresponding to ultimate load and failure mode. Generally, it is shown that the higher strain rate on the bolted connection specimens, the higher ultimate load was obtained. The ultimate loads were averagely 2-6% higher, while the corresponding elongations were averagely 8-9% higher for the test results obtained from the strain rate of 20 mm/min compared with those obtained from the lower strain rates (1.0 mm/min for carbon steel and 1.5 mm/min for stainless steel). The connection specimens were generally failed in plate bearing of the carbon steel and stainless steel. It is shown that increasing the strain rate up to 20 mm/min generally has no effect on the bearing failure mode of the carbon steel and stainless steel bolted connections. The test strengths and failure modes were compared with the results predicted by the bolted connection design rules in international design specifications, including the Australian/New Zealand Standard (AS/NZS4600 2018), Eurocode 3 - Part 1.3 (EC3-1.3 2006) and North American Specification (AISI S100 2016) for cold-formed carbon steel structures as well as the American Specification (ASCE 2002), AS/NZS4673 (2001) and Eurocode 3 - Part 1.4 (EC3-1.4 2015) for stainless steel structures. It is shown that the AS/NZS4600 (2018), EC3-1.3 (2006) and AISI S100 (2016) generally provide conservative predictions for the carbon steel bolted connections. Both the ASCE (2002) and the EC3-1.4 (2015) provide conservative predictions for the stainless steel bolted connections. The EC3-1.3 (2006) generally provided more accurate predictions of failure mode for carbon steel bolted connections than the AS/NZS4600 (2018) and the AISI S100 (2016). The failure modes of stainless steel bolted connections predicted by the EC3-1.4 (2015) are more consistent with the test results compared with those predicted by the ASCE (2002).
Keywords
bearing failure; bolted connection; carbon steel; experimental investigation; strain rate; stainless steel;
Citations & Related Records
Times Cited By KSCI : 9  (Citation Analysis)
연도 인용수 순위
1 Kim, T.S. and Kuwamura, H. (2007), "Finite element modeling of bolted connections in thin-walled stainless steel plates under static shear", Thin-Wall. Struct., 45(4), 407-421.   DOI
2 Li, D., Uy, B., Patel, V. and Aslani, F. (2016), "Behaviour and design of demountable steel column-column connections", Steel Compos. Struct., Int. J., 22(2), 429-448.   DOI
3 Li, G.-Q., Gu, F., Jiang, J. and Sun, F. (2017a), "Cyclic behavior of steel beam-concrete wall connections with embedded steel columns (I): Experimental study", Steel Compos. Struct., Int. J., 23(4), 399-408.   DOI
4 Li, G.-Q., Gu, F., Jiang, J. and Sun, F. (2017b), "Cyclic behavior of steel beam-concrete wall connections with embedded steel columns (II): Theoretical study", Steel Compos. Struct., Int. J., 23(4), 409-420.   DOI
5 Li, S., Li, Q., Jiang, H., Zhang, H., Yan, L. and Jiang, W. (2018), "Experimental study on a new type of assembly bolted endplate connection", Steel Compos. Struct., Int. J., 26(4), 463-471.
6 Lu, G.X. and Yu, T.X. (2003), "Energy absorption of structures and materials", Woodhead Publishing, Oxford, UK.
7 Pan, C.L., Wu, S. and Yu, W.W. (2001), "Strain rate and aging effect on the mechanical properties of sheet steels", Thin-Wall. Struct., 39, 429-444.   DOI
8 Rathnaweera, G., Durandet, Y., Ruan, D. and Kinoshita, S. (2011), "Characterizing the material properties of a tube from a lateral compression test", Int. J. Protect. Struct., 2(4), 465-476.   DOI
9 Rogers, C.A. and Hancock, G.J. (1998), "Bolted connection tests of thin G550 and G300 sheet steels", J. Struct. Eng., 124(7), 798-808.   DOI
10 Rogers, C.A. and Hancock, G.J. (1999), "Bolted connection design for sheet steels less than 1.0 mm thick", J. Constr. Steel Res., 51(2), 123-146.   DOI
11 Salih, E.L., Gardner, L. and Nethercot, D.A. (2010), "Numerical investigation of net section failure in stainless steel bolted connections", J. Constr. Steel Res., 66(12), 1455-1466.   DOI
12 Salih, E.L., Gardner, L. and Nethercot, D.A. (2011), "Bearing failure in stainless steel bolted connections", Eng. Struct., 33(2), 549-562.   DOI
13 Soroushian, P. and Choi, K.B. (1987), "Steel mechanical properties at different strain rates", J. Struct. Eng., 113(4), 663-672.   DOI
14 Teh, L.H. and Clements, D.D.A. (2012), "Block shear capacity of bolted connections in cold-reduced steel sheets", J. Struct. Eng., 138(4), 459-467.   DOI
15 Teh, L.H. and Uz, M.E. (2015), "Ultimate shear-out capacities of structural-steel bolted connections", J. Struct. Eng., 141(6), 04044152.
16 Vatansever, C. and Kutsal, K. (2018), "Effect of bolted splice within the plastic hinge zone on beam-to-column connection behaviour", Steel Compos. Struct., Int. J., 28(6), 767-778.
17 Yan, S. and Young, B. (2011), "Tests of single shear bolted connections of thin sheet steels at elevated temperatures -Part I: steady state tests", Thin-Wall. Struct., 49, 1320-1333.   DOI
18 Yan, S. and Young, B. (2012), "Bearing factors for single shear bolted connections of thin sheet steels at elevated temperatures", Thin-Wall. Struct., 52, 126-142.   DOI
19 Yan, S. and Young, B. (2013), "Effects of Elevated Temperatures on Double Shear Bolted Connections of Thin Sheet Steels", J. Struct. Eng., 139, 757-771.   DOI
20 Yuen, S.C.K., Nurick, G.N. and Witbeen, H.L. (2011), "The response of sandwich panels made of thin-walled tubes subjected to axial load", Int. J. Protect. Struct., 2(4), 477-498.   DOI
21 AS/NZS4673 (2001), Cold-formed stainless steel structures; AS/NZS 4673:2001, Australian/New Zealand Standard (AS/NZS), Standards Australia, Sydney, Australia.
22 Agheshlui, H., Goldsworthy, H., Gad, E. and Mirza, O. (2017), "Anchored blind bolted composite connection to a concrete filled steel tubular column", Steel Compos. Struct., Int. J., 23(1), 115-130.   DOI
23 AISI S100 (2016), North American Specification for the Design of Cold-Formed Steel Structural Members; American Iron and Steel Institute, AISIS 100-2016, AISI Standard.
24 ASCE (2002), Specification for the design of cold-formed stainless steel structural members; American Society of Civil Engineers (ASCE), ASCE Standard, SEI/ASCE-8-02, Reston, VA, USA.
25 AS/NZS4600 (2018), Cold-formed Steel Structures; Australian/New Zealand Standard, AS/NZS4600:2018, Sydney, Australia, Standards Australia.
26 Cai, Y. and Young, B. (2014a), "Structural behavior of coldformed stainless steel bolted connections", Thin-Wall. Struct., 83, 147-156.   DOI
27 Zeinoddini, M., Parke, G.A.R. and Harding, J.E. (2002), "Axially pre-loaded steel tubes subjected to lateral impacts: an experimental study", Int. J. Impact Eng., 27(6), 669-690.   DOI
28 Zeinoddini, M., Harding, J.E. and Parke, G.A.R. (2008), "Axially pre-loaded steel tubes subjected to lateral impacts (a numerical simulation)", Int. J. Impact Eng., 35(11), 1267-1279.   DOI
29 Boh, J.W., Louca, L.A. and Choo, Y.S. (2004), "Strain rate effects on the response of stainless steel corrugated firewalls subjected to hydrocarbon explosions", J. Constr. Steel Res., 60, 1-29.   DOI
30 Bouchair, A., Averseng, J. and Abidelah, A. (2008), "Analysis of the behaviour of stainless steel bolted connections", J. Constr. Steel Res., 64(11), 1264-1274.   DOI
31 Cai, Y. and Young, B. (2018), "Bearing resistance design of stainless steel bolted connections at ambient and elevated temperatures", Steel Compos. Struct., Int. J., 29(2), 273-286.
32 Cai, Y. and Young, B. (2014b), "Behavior of cold-formed stainless steel single shear bolted connections at elevated temperatures", Thin-Wall. Struct., 75, 63-75.   DOI
33 Cai, Y. and Young, B. (2014c), "Transient state tests of coldformed stainless steel single shear bolted connections", Eng. Struct., 81, 1-9.   DOI
34 Cai, Y. and Young, B. (2015), "High temperature tests of coldformed stainless steel double shear bolted connections", J. Constr. Steel Res., 104, 49-63.   DOI
35 Cai, Y. and Young, B. (2019), "Carbon steel and stainless steel bolted connections undergoing unloading and re-loading processes", J. Constr. Steel Res., 157, 337-346.   DOI
36 Chung, K.F. (2005), "Structural performance of cold-formed steel structures with bolted connections", Adv. Struct. Eng., 8(3), 231-245.   DOI
37 AS1391 (2007), Metallic materials-Tensile testing at ambient temperature; AS1391:2007, Standards Australia, Sydney, Australia.
38 EC3-1.3 (2006), Eurocode 3 - Design of Steel Structures - Part 1.3: General Rules Supplementary Rules for Cold-formed Members and Sheeting; European Committee for Standardization, EN1993-1-3:2006, Brussels, Belgium.
39 De Nardin, S. and El Debs, A.L.H.C. (2018), "Shear transfer mechanism in connections involving concrete filled steel columns under shear forces", Steel Compos. Struct., Int. J., 28(4), 449-460.
40 Esaki, F. and Ono, M. (2001), "Effects of loading rate on mechanical behavior of SRC shear walls", Steel Compos. Struct., Int. J., 1(2), 201-212.   DOI
41 EC3-1.4 (2015), Eurocode 3 - Design of steel structures - Part 1.4: General rules - Supplementary rules for stainless steels; EN 1993-1-4:2006+A1:2015, European Committee for Standardization, Brussels, Belgium.
42 EC3-1.8 (2005), Eurocode 3 - Design of steel structures-Part 1.8: Design of joints; European Committee for Standardization, BS EN 1993-1-8:2005, CEN, Brussels, Belgium.
43 El Hassouni, A, Plumier, A. and Cherrabi, A. (2011), "Experimental and numerical analysis of the strain-rate effect on fully welded connections", J. Constr. Steel Res., 67(3), 533-546.   DOI
44 Girhammar, U.A. and Andersson, H. (1988), "Effect of loading rate on nailed timber joint capacity", J. Struct. Eng., 114(11), 2439-2456.   DOI
45 Grimsmo, E.L., Clausen, A.H., Langseth, M. and Aalberg, A. (2015), "An experimental study of static and dynamic behavior of bolted end-plate joints of steel", Int. J. Impact Eng., 85, 132-145.   DOI
46 Jones, N. (1997), Structural impact, Cambridge University Press Cambridge, UK.
47 Kazemi, K.S.M., Sohrabi, M.R. and Kazemi, H.H. (2018), "Evaluation the behavior of pre-fabricated moment connection with a new geometry of pyramidal end block under monotonic and cyclic loadings", Steel Compos. Struct., Int. J., 29(3), 391-404.