Abstract
In steel frame-tube structures (SFTSs) the application of flexural beam is not suitable for the beam with span-to-depth ratio lower than five because the plastic hinges at beam-ends can not be developed properly. This can lead to lower ductility and energy dissipation capacity of the SFTS. To address this problem, a replaceable shear link, acting as a ductile fuse at the mid length of deep beams, is proposed. SFTS with replaceable shear links (SFTS-RSLs) dissipate seismic energy through shear deformation of the link. In order to evaluate this proposal, buildings were designed to compare the seismic performance of SFTS-RSLs and SFTSs. Several sub-structures were selected from the design buildings and finite element models (FEMs) were established to study their hysteretic behavior. Static pushover and dynamic analyses were undertaken in comparing seismic performance of the FEMs for each building. The results indicated that the SFTS-RSL and SFTS had similar initial lateral stiffness. Compared with SFTS, SFTS-RSL had lower yield strength and maximum strength, but higher ductility and energy dissipation capacity. During earthquakes, SFTS-RSL had lower interstory drift, maximum base shear force and story shear force compared with the SFTS. Placing a shear link at the beam mid-span did not increase shear lag effects for the structure. The SFTS-RSL concentrates plasticity on the shear link. Other structural components remain elastic during seismic loading. It is expected that the SFTS-RSL will be a reliable dual resistant system. It offers the benefit of being able to repair the structure by replacing damaged shear links after earthquakes.
Keywords
steel frame-tube structure (SFTS); replaceable shear link; hysteretic behaviors; dynamic behaviors; finite element analyses;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 Okazaki, T., Arce, G., Ryu, H.C. and Engelhardt, M.D. (2005), "Experimental study of local buckling, overstrength, and fracture of links in eccentrically braced frames", J. Struct. Eng., 131(10), 1526-1535.   DOI
2 Rahgozar, R., Ahmadi, A.R., Ghelichi, M., Goudarzi, Y., Malekinejad, M. and Rahgozar, P. (2014), "Parametric stress distribution and displacement functions for tall buildings under lateral loads", Struct. Des. Tall Special Build., 23(1), 22-41.   DOI
3 Rossi, P.P. and Lombardo, A. (2007), "Influence of the link overstrength factor on the seismic behaviour of eccentrically braced frames", J. Constr. Steel Res., 63(11), 1529-1545.   DOI
4 Shayanfar, M.A., Barkhordari, M.A. and Rezaeian, A.R. (2012), "Experimental study of cyclic behavior of composite vertical shear link in eccentrically braced frames", Steel Compos. Struct., Int. J., 12(1), 13-29.   DOI
5 Taranath, B.S. (2011), Structural Analysis and Design of Tall Buildings: Steel and Composite Construction, CRC Press.
6 Tavakoli, R., Rahgozar, R. and Kamgar, R. (2018), "The best location of belt truss system in tall buildings using multiple criteria subjected to blast loading", Civil Eng. J., 4(6), 1338-1353.   DOI
7 Caprili, S., Mussini, N. and Salvatore, W. (2018), "Experimental and numerical assessment of EBF structures with shear links", Steel Compos. Struct., Int. J., 28(2), 123-138.
8 AISC 358-10 (2010), Prequalified connections for special and intermediate steel moment frames for seismic applications; Chicago, IL, USA.
9 Alavi, A., Rahgozar, P. and Rahgozar, R. (2018), "Minimumweight design of high-rise structures subjected to flexural vibration at a desired natural frequency", Struct. Des. Tall Special Build., 27(15), e1515.   DOI
10 Bahrami, S., Madhkhan, M., Shirmohammadi, F. and Nazemi, N. (2017), "Behavior of two new moment resisting precast beam to column connections subjected to lateral loading", Eng. Struct., 132, 808-821.   DOI
11 Charney, F.A. and Pathak, R. (2008a), "Sources of elastic deformation in steel frame and framed-tube structures: part 1: simplified subassemblage models", J. Constr. Steel Res., 64(1), 87-100.   DOI
12 Charney, F.A. and Pathak, R. (2008b), "Sources of elastic deformations in steel frame and framed-tube structures: part 2: detailed subassemblage models", J. Constr. Steel Res., 64(1), 101-117.   DOI
13 Ellingwood, B.R. (2001), "Earthquake risk assessment of building structures", Reliabil. Eng. Syst. Safety, 74(3), 251-262.   DOI
14 AISC 341-10 (2010), Seismic provisions for structural steel buildings; Chicago, IL, USA.
15 Memari, M., Mahmoud, H. and Ellingwood, B. (2014), "Postearthquake fire performance of moment resisting frames with reduced beam section connections", J. Constr. Steel Res., 103, 215-229.   DOI
16 FEMA (1997), NEHRP commentary on the guidelines for the seismic rehabilitation of buildings; FEMA-274, Federal Emergency Management Agency (FEMA); Washington D.C., USA.
17 FEMA (2000), State of the art report on connection performance; FEMA-355D, Federal Emergency Management Agency (FEMA); Washington D.C., USA.
18 GB50011-2010 (2010), Code for seismic design of buildings; Beijing, China.
19 Ramirez, C.M., Lignos, D.G., Miranda, E. and Kolios, D. (2012), "Fragility functions for pre-northridge welded steel momentresisting beam-to-column connections", Eng. Struct., 45(2284), 574-584.   DOI
20 Sheet, I.S., Gunasekaran, U. and Macrae, G.A. (2013), "Experimental investigation of cft column to steel beam connections under cyclic loading", J. Constr. Steel Res., 86(86), 167-182.   DOI
21 JGJ 99-2015 (2015), Technical specification for steel structure of tall buildings; Beijing, China.
22 Kamgar, R. and Rahgozar, R. (2013), "A simple approximate method for free vibration analysis of framed tube structures", Struct. Des. Tall Special Buildi., 22(2), 217-234.   DOI
23 Lian, M., Su, M.Z. and Guo, Y. (2015), "Seismic performance of eccentrically braced frames with high strength steel combination", Steel Compos. Struct., Int. J., 18(6), 1517-1539.   DOI
24 Nikoukalam, M.T. and Dolatshahi, K.M. (2015), "Development of structural shear fuse in moment resisting frames", J. Constr. Steel Res., 114, 349-361.   DOI
25 Lian, M., Su, M.Z. and Guo, Y. (2017), "Experimental performance of Y-shaped eccentrically braced frames fabricated with high strength steel", Steel Compos. Struct., Int. J., 24(4), 441-453.
26 Mahmoudi, F., Dolatshahi, K.M., Mahsuli, M., Shahmohammadi, A. and Nikoukalam, M.T. (2016), "Experimental evaluation of steel moment resisting frames with a nonlinear shear fuse", In: Geotechnical and Structural Engineering Congress.
27 Malekinejad, M., Rahgozar, R., Malekinejad, A. and Rahgozar, P. (2016), "A continuous-discrete approach for evaluation of natural frequencies and mode shapes of high-rise buildings", Int. J. Adv. Struct. Eng., 8(3), 269-280.   DOI
28 McCormick, D., Aburano, H., Ikenaga, M. and Nakashima, M. (2008), "Permissible residual deformation level for building structures considering both safety and human elements", Proceedings of the 14th World Conference on Earthquake Engineering, Beijing, China.
29 Moon, K.S. (2010), "Stiffness-based design methodology for steel braced tube structures: a sustainable approach", Steel Constr., 32(10), 3163-3170.
30 Oh, K., Lee, K., Chen, L., Hong, S.B. and Yang, Y. (2015), "Seismic performance evaluation of weak axis column-tree moment connections with reduced beam section", J. Constr. Steel Res., 105, 28-38.   DOI
31 Okazaki, T. and Engelhardt, M.D. (2015), "Cyclic loading behavior of EBF links constructed of ASTM A992 steel", J. Constr. Steel Res., 63(6), 751-765.   DOI