Browse > Article
http://dx.doi.org/10.12989/scs.2018.27.4.453

Strengthening of reinforced concrete beams using external steel members  

Demir, Ali (Manisa Celal Bayar University, Department of Civil Engineering)
Ercan, Emre (Ege University, Department of Civil Engineering)
Demir, Duygu Donmez (Manisa Celal Bayar University, Department of Mathematics)
Publication Information
Steel and Composite Structures / v.27, no.4, 2018 , pp. 453-464 More about this Journal
Abstract
The objective of this study is to devise an alternative strengthening method to the ones available in the literature. So, external steel members were used to enhance both flexural and shear capacities of reinforced concrete (RC) beams having insufficient shear capacity. Two types of RC beams, one without stirrups and one with lacking stirrups, were prepared in the study. These beams were strengthened with external steel clamps devised by the authors and with external longitudinal reinforcements. Although the use of clamps alone didn't have a significant effect on the load carrying capacity of the tested beams, the ductility increased approximately tenfold and the failure behavior changed from brittle to ductile. Although the use of clamps and longitudinal reinforcements together did not significantly increase the ductility of the beams, it approximately doubled their load capacities. The results of the experimental study were compared to the ones obtained from nonlinear finite element analysis (NLFEA) and it was observed that they were compatible. Finally, it can be concluded that the devised method could be applied to structural members as an alternative to methods in application due to lightness, low-cost, easy applicable and reliable.
Keywords
RC beam; strengthening; external clamp; shear; test; finite elements;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 Adhikary, B.B. and Mutsuyoshi, H. (2006), "Shear strengthening of RC beams with web-bonded continuous steel plates", Constr. Build. Mater., 20(5), 296-307.   DOI
2 Altin, S., Tankut, T., Anil, O . and Demirel, Y. (2003), "Response of reinforced concrete beams with clamps applied externally: An experimental study", Eng. Struct., 25(6), 1217-1229.   DOI
3 Arslan, G., Sevuk, F. and Ekiz, I. (2008), "Steel plate contribution to load-carrying capacity of retrofitted RC beams", Constr. Build. Mater., 22(3), 143-153.   DOI
4 Ceroni, F. (2010), "Experimental performances of RC beams strengthened with FRP materials", Constr. Build. Mater., 24(9), 1547-1559.   DOI
5 Chalioris, C.E., Thermou, G.E. and Pantazopoulou, S.J. (2014), "Behaviour of rehabilitated RC beams with self-compacting concrete jacketing - Analytical model and test results", Constr. Build. Mater., 55, 257-273.   DOI
6 Hamad, B., Masri, A., Basha, H. and Baalbaki, O. (2011), "Behavior of T-shaped reinforced concrete beams partially confined by structural steel", Constr. Build. Mater., 25(2), 1037-1043.   DOI
7 Hawileh, R.A., Naser, M., Zaidan, W. and Rasheed, H.A. (2009), "Modeling of insulated CFRP-strengthened reinforced concrete T-beam exposed to fire", Eng. Struct., 31(12), 3072-3079.   DOI
8 Kisicek, T., Soric, Z. and Rak, M. (2007), "Testing beams and slabs reinforced with FRP bars", Gradev., 59(7), 581-595.
9 Kothandaraman, S. and Vasudevan, G. (2010), "Flexural retrofitting of RC beams using external bars at soffit level-An experimental study", Constr. Build. Mater., 24(11), 2208-2216.   DOI
10 Mofidi, A. and Chaallal, O. (2014), "Tests and design provisions for reinforced-concrete beams strengthened in shear using FRP sheets and strips", Int. J. Concr. Struct. M., 8(2), 117-128.   DOI
11 Osman, B.H., Wu, E., Bohai, J. and Abdallah, M. (2017), "Repair technique of pre-cracked reinforced concrete (RC) beams with transverse openings strengthened with steel plate under sustained load", J. Adhes. Sci. Technol., 31(21), 2360-2379.   DOI
12 Qin, S., Dirar, S., Yang, J., Chan, A.H.C. and Elshafie, M. (2015), "CFRP shear strengthening of reinforced-concrete T-beams with corroded shear links", J. Compos. Constr. -ASCE, 19(5), 04014081.   DOI
13 Swamy, R.N., Jones, R. and Charif, A. (2008), "The effect of external plate reinforcement on the strengthening of structurally damaged RC beams", Struct. Eng., 67(3), 45-56.
14 Su, R.K.L., Siu, W.H. and Smith, S.T. (2010), "Effects of bolt plate arrangements on steel plate strengthened reinforced concrete beams", Eng. Struct., 32(6), 1769-1778.   DOI
15 TS500 (2000), Requirements for design and construction of reinforced concrete structures; Turkish Standards Institution, Ankara, Turkey. [In Turkish]
16 TS708 (2010), Steel Bars for Concrete; Turkish Standards Institution, Ankara, Turkey. [In Turkish]
17 Wong, P.S. and Vecchio, F.J. (2002), VecTor 2, Formworks User's Manual.
18 Vecchio, F.J. (2000), "Disturbed stress field model for reinforced concrete: formulation", J. Struct. Eng., 126(9), 1070-1077.   DOI
19 Vecchio, F.J. and Collins, M.P. (1986), "The modified compression field theory for reinforced concrete elements subject to shear", ACI Journal, 83(2), 219-231.
20 Vecchio, F.J. and Shim, W. (2004), "Experimental and analytical reexamination of classic concrete beam tests", J. Struct. Eng., 130(3), 460-469.   DOI
21 Zhang, D., Ueda, T. and Furuuchi, H. (2012), "Concrete cover separation failure of overlay strengthened reinforced concrete beams", Constr. Build. Mater., 26(1), 735-745.   DOI
22 Wu, Y. and Liu, K. (2013), "Characterization of Mechanically Enhanced FRP Bonding System", J. Compos. Constr., 17(1), 34-49.   DOI
23 Yang, S. Cao, S. and Gu, R. (2015), "New technique for strengthening reinforced concrete beams with composite bonding steel plates", Steel Compos. Struct., Int. J., 19(3), 735-757.   DOI