Browse > Article
http://dx.doi.org/10.12989/scs.2017.24.3.277

Design of lightweight mansard portal frames  

Morales-Rodriguez, P.A. (Departamento de Produccion Vegetal y Tecnologia Agraria, Escuela Tecnica Superior de Ingenieros Agronomos, University of Castilla-La Mancha (UCLM))
Lopez-Perales, J.A. (Departamento de Produccion Vegetal y Tecnologia Agraria, Escuela Tecnica Superior de Ingenieros Agronomos, University of Castilla-La Mancha (UCLM))
Moreno, M.C. Serna (Instituto de Investigaciones Energeticas y Aplicaciones Industriales, Escuela Tecnica Superior de Ingenieros Industriales (UCLM))
Publication Information
Steel and Composite Structures / v.24, no.3, 2017 , pp. 277-285 More about this Journal
Abstract
Single-storey industrial buildings are one of the most often type of structures built among various skeletal framed steel constructions. These metallic buildings offer an exceptional opportunity to minimise the material employed, contributing to a more sustainable construction. In particular, the mansard portal frame is a typology made up of broken beams that involves different lengths and discontinuous slopes. This study aims the weight reduction of the standard mansard portal frame with design purposes by means of varying four parameters: the kink position, the eaves-apex slope, the span and the columns height. In this work, we suggest some guidelines that can improve the economical competitive capabilities of their structural design. In all the cases analysed, the joints of the portal frame are placed over the theoretical non-funicular shape to uniform loads. This allows reducing the bending moment and the shear force, but increasing the axial force. In addition, the performance of mansard and typical pitched portal frames submitted to the same boundary conditions is compared in terms of efficiency in the use of steel. In the large majority of the cases, mansard typologies are lighter than the common pitched frames and, hence, more economical.
Keywords
steel structures; structural design; structural steel; limit state design; hot-rolled steel members; mansard portal frame; kink joint;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 Artar, M. and Daloglu, A.T. (2015a), "Optimum design of steel space frames with composite beams using genetic algorithm", Steel Compos. Struct., Int. J., 19(2), 503-519.   DOI
2 Artar, M. and Daloglu, A.T. (2015b), "Optimum design of steel frames with semi-rigid connections and composite beams", Struct. Eng. Mech., Int. J., 55(2), 299-313.   DOI
3 CTE (2006), Codigo Tecnico de la Edificacion, Ministerio de Fomento; Gobierno de Espana, Madrid, Spain.
4 CTE DB SE-A (2007), Codigo Tecnico de la Edificacion. Documento Basico: Seguridad Estructural-Acero; Ministerio de Fomento, Gobierno de Espana, Madrid, Spain.
5 CTE DB SE-AE (2009), Codigo Tecnico de la Edificacion. Documento Basico: Seguridad Estructural-Acciones en la edificacion; Ministerio de Fomento, Gobierno de Espana, Madrid, Spain.
6 Dai, S.J., Qian, M. and Lu, H. (2015), "Optimal design of portal frame structure based on the dimension of the issues", Proceedings of International Conference on Mechanics, Building Material and Civil Engineering, Guilin, China, August, pp. 331-335.
7 Davison, B. and Owens, G.W. (2008), Steel Designers' Manual, Wiley-Blackwell.
8 EAE (2012), Instruccion de Acero Estructural, Ministerio de Fomento; Gobierno de Espana, Madrid. Spain.
9 Eurocode 3 (2005), Design of steel structures; European Committee for Standardization, Brussels, Belgium.
10 Flick, A. and Fliegel, G. (2013), "Trends in the steel industry: innovative solutions to drive sustainability", Trans. Indian Inst. Met., 66(5-6), 535-541.   DOI
11 Gholizadeh, S. and Poorhoseini, H. (2015), "Optimum design of steel frame structures by a modified dolphin echolocation algorithm", Struct. Eng. Mech., Int. J., 55(3), 535-554.   DOI
12 Gozalvez, J.J.F., Gisbert, C.F., Santafe, M.R., Romero, F.J.S. and Soler, J.B.T. (2014), "Elastoplastic analysis of double-pitched portal frames", VII Congreso Iberico De Agroingenieria Y Ciencias Horticolas: Innovar Y Producir Para El Futuro, 363-368.
13 Khan, F.R. (1980), "Structural aesthetics in architecture and its social and technological relevance", Proceedings of IABSE Congress, Vienna, Austria, August-September.
14 Hernandez, S., Fontan, A.N., Perezzan, J.C. and Loscos, P. (2005), "Design optimization of steel portal frames", Adv. Eng. Software, 36(9), 626-633.   DOI
15 Hradil, P., Mielonen, M. and Fulop, L. (2010), "Advanced design and optimization of steel portal frames", J. Struct. Mech., 43(1), 44-60.
16 Jackson, H.A. and Masse, D.I. (1992), Gambrel roof braced rafters. PLAN M-9250, Ministry of Agriculture, Food and Fisheries.
17 Jackson, H.A. and Turnbull, J.E. (1979), "Gambrel roof arches for farm and storage buildings", Can. Agricul. Eng., 21(1), 47-51.
18 Jorquera Lucerga, J.J. and Manterola Armisen, J. (2012), "An iterative form-finding method for antifunicular shapes in spatial arch bridges", Comput. Struct., 108, 42-60.
19 Kravanja, S. and Zula, T. (2010), "Cost optimization of industrial steel building structures", Adv. Eng. Software, 41(3), 442-450.   DOI
20 Kravanja, S., Turkalj, G., Silih, S. and Zula, T. (2013), "Optimal design of single-story steel building structures based on parametric MINLP optimization", J. Constr. Steel Res., 81, 86-103.   DOI
21 Lawson, M. and Trebilcock, P. (2004), Architectural Design in Steel, Taylor & Francis.
22 Gurung, N. and Mahendran, M. (2002), "Comparative life cycle costs for new steel portal frame building systems", Build. Res. Inform., 30(1), 35-46.   DOI
23 Lim, J.B.P., King, C.; Rathbone, A., Davies, J., Edmondson, V., (2005), "Eurocode 3 and the in-plane stability of portal frames", The Struct. Engr., 83(21), 43-49.
24 Morris, L.J. and Plum, D.R. (1988), Structural Steelwork Design to BS5950, Longman Scientific & Technical.
25 Lopez-Perales, J.A. (2004), "Modelo de elementos finitos para el calculo de arcos. Validacion en estructuras agroindustriales de acero", Ph.D. Dissertation; Universidad de Castilla-La Mancha, Albacete, Spain.
26 McKinstray, R., Lim, J.B.P., Tanyimboh, T.T., Phan, D.T. and Sha, W. (2015), "Optimal design of long-span steel portal frames using fabricated beams", J. Constr. Steel Res., 104, 104-114.   DOI
27 McKinstray, R., Lim, J.B.P., Tanyimboh, T.T., Phan, D.T. and Sha, W. (2016), "Comparison of optimal design of steel portal frames including topological asymmetry considering rolled, fabricated and tapered sections", Eng. Struct., 111, 505-524.   DOI
28 Moller, O., Foschi, R.O., Quiroz, L.M. and Rubinstein, M. (2009), "Structural optimization for performance-based design in earthquake engineering: Applications of neural networks", Struct. Safe., 31(6), 490-499.   DOI
29 Morales-Rodriguez, P.A. (2015), "Diseno optimo de porticos poligonales de acero. Estudio de la union del quiebro por el Metodo de los Elementos Finitos", Ph.D. Dissertation; Universidad de Castilla-La Mancha, Albacete, Spain.
30 Mosquera, J.C. and Gargoum, L.A. (2014), "A sequential algorithm for minimum weight design of 2-D steel portal frames using Eurocode 3", Int. J. Steel Struct., 14(1), 141-149.   DOI
31 Phan, D.T., Lim, J.B.P., Tanyimboh, T.T., Lawson, R.M., Xu, Y., Martin, S. and Sha, W. (2013), "Effect of serviceability limits on optimal design of steel portal frames", J. Constr. Steel Res., 86, 74-84.   DOI
32 Regalado, F. (1999), Breve Introduccion a las Estructuras y sus Mecanismos Resistentes, CYPE Ingenieros, Alicante, Spain.
33 Salter, P.R., Malik, A.S. and King, C. (2004), Desing of Single-Span Steel Portal Frames to BS 5950-1:2000, The Steel Construction Institute, Berkshire, UK.
34 Torroja, E. (1962), Philosophy of Structures, University of California Press, Berkeley and Los Angeles, USA.
35 Sarma, K.C. and Adeli, H. (2000), "Cost optimization of steel structures", Eng. Optimiz., 32(6), 777-802.   DOI
36 SCI (2010), AD-090: Deflection limits for pitched roof portal frames (Amended), The Steel Construction Institute.